• Title/Summary/Keyword: OPC replacement

Search Result 147, Processing Time 0.019 seconds

Influence of Blast Furnace Slag and Anhydrite on Strength of Shotcrete (고로슬래그와 무수석고가 숏크리트의 강도에 미치는 영향)

  • Ryu, Sung-Hee;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.87-95
    • /
    • 2012
  • This study investigated the compressive strength, flexural strength, setting time, and rebound when blast furnace slag and anhydrite, which are widely used mineral admixtures for concrete, are applied to shotcrete. When Ordinary Portland Cement (OPC) was replaced at a rate of 10% with blast furnace slag and anhydrite, the initial and final setting time requirements were all satisfied. However, when OPC was replaced at a rate of 20%, final setting was delayed, revealing that this mixture was not suitable for shotcrete. Compressive strength test results showed that the mixture with 10% OPC replacement rate met the target strength at 1 day and 28 days for permanent tunnel support usage. Particularly, the mixture designed with OPC replacement by blast furnace slag and anhydrite at rates of 5% showed the highest compressive strength. Rebound measurements revealed that this mixture exhibited excellent performance with 23% reduction in the rebound compared to the shotcrete that was produced with only OPC binder.

Strength Development of Fly ash Substituted Concrete due to Blast Furnace Slag Powder and Gypsum Addition (고로슬래그 미분말 및 석고혼입에 따른 플라이애시 치환 콘크리트의 강도발현 특성)

  • Han, Cheon-Goo;Han, Min-Cheol;Jeon, Kyu-Nam
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • In this study, the effect of blast furnace slag and gypsum addition on strength development of fly ash substituted concrete is investigated experimentally. As a result, the fluidity represented a similar or larger level than that of OPC but showed a tendency to decrease the fluidity according to the increase in the replacement level of BS and GS for the FA replacement concrete. In the case of the air content, although it showed a larger decrease compared to that of OPC, it also represented that BS and GS did not affect the air content significantly. Regarding the compressive strength in the case of the replacement of BS and GS for the FA 10% replacement concrete, it showed a higher early strength than OPC. Whereas, in the case of the BS 5% replacement and GS 1% incorporation for the FA 10% replacement concrete showed the most excellent performance due to its high strength. In the correlation of the compressive strength according to the kinds of admixtures, it was evident that the GS incorporation played an important role in high strength gain.

  • PDF

Mechanical Properties of Early Strength Mortar with Ground Granulated Blast Furnace Slag and Expansive Additive (고로슬래그미분말 및 팽창재를 혼입한 조강형 모르타르의 역학적 특성)

  • Koo, Kyung-Mo;Choi, Jae-Won;You, Byeong-Know;Cha, Wan-Ho;Kang, Bong-Hee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.177-184
    • /
    • 2021
  • In this study, the effects of ground granulated blast furnace slag(GGBFS) and expansive additive(EA) on early strength mortar were examined for the purpose of reducing carbon and improving cement performance. As a result, ealry strength Portland cement(EPC) tended to decrease in flow compared to ordinary Portland cement(OPC), but binder with EPC and GGBFS was possible to obtain higher liquidity than OPC. EPC showed higher compressive strength and shrinkage than OPC. The compressive strength of specimen with EPC and GGBFS was reduced proportionally to the replacement ratio of GGBFS. The replacement ratio of GGBFS above the compressive strength equivalent to OPC was higher under low temperature conditions. The use of GGBFS resulted in high shrinkage compared to OPC, and this characteristic was even greater under low temperature conditions. The shrinkage of specimen with EA was decreased in early ages, but was higher than the OPC in long-term ages.

Material Properties of Concrete Produced with Limestone Blended Cement (석회석 혼합 시멘트로 제조된 콘크리트의 기초 물성)

  • Bang, Jin-Wook;Kwon, Seung-Jun;Shin, Kyung-Joon;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 2015
  • This paper presents an experimental investigation in order to evaluate fresh and hardened properties of LP (Limestone Powder) blended cement concrete. The cement contents of the mixtures are replaced by LP in the range of 10%, 15%, 25%, and 35%, while a control mixture is prepared with only OPC (Ordinary Portland Cement). The fresh concrete properties like slump and air content are similar to those of control mixture up to 35% of replacement ratio of LP, however a delay in setting time is evaluated. The hardened properties including compressive strength, flexural strength, and rapid freezing and thawing resistance shows similar results of control mixture up to 15% of replacement. Relatively lower strength development is evaluated over 25% replacement of LP. For accelerated carbonation test, resistance to carbonation rapidly decreases with increasing LP replacement ratio due to the limited amount of $Ca(OH)_2$. From the study, LP replacement under 15% can be adopted considering reduction of strength and resistance to carbonation.

The Properties of OPC-Slag Cement Mixed with Nano-Silica Solution by Mixing Water Weight Replacement Method (나노실리카 졸을 배합수 중량치환 방법으로 혼합한 OPC-slag cement의 특성)

  • Seo, Ki-Young;Kim, Taewan;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.24-34
    • /
    • 2020
  • This research is a study on the characteristics of OPC-slag cement using nano-silica solution (NSS) with water-weight substitution method. The new replacement method is a fundamental step to study the behavior of cement with higher NSS replacement rates than previous studies. NSS was replaced by 10%, 20%, 30%, 40%, and 50% of the mixing water weight. As a result, the mechanical and microstructural characteristics were improved. This can be summarized in two ways. First, when the NSS is replaced with mixing water, the homogeneous dispersion action of the nano-silica particles is improved. This promotes initial hydration. Second, substitution of NSS with higher density than mixing water reduces w / b. This forms a dense hydration reaction material. The new substitution method did not show any degradation of mechanical and microstructural properties as compared with the results using the powdered nano-silica particles revealed in the previous study. Therefore, it is considered that the method of weight substitution of NSS used in this study can be applied to the formulation of OPC-slag cement.

Properties of Shrinkage and Strength of Concrete Incorporating Blast-furnace Slag (고로슬래그 치환율 변화에 따른 고강도 콘크리트의 강도 및 수축 특성)

  • Son, Ho Jung;Noh, Sang-Kyun;Kim, Seoung Hwan;Han, Min Cheol;Baek, Joo Hyun;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.99-102
    • /
    • 2008
  • This study investigates the properties of the flow, air content, strength, hydration heat, and the autogenous shrinkage, and the results are summarized as following. As a properties of fresh concrete, the flow increased and the air content decreased as the replacement ratio of BS increased. The time of set delayed as the replacement ratio of BS increased by latent hydraulicity. The compressive strength of hardening concrete was smaller than OPC as the replacement ratio of BS increased at young concrete, however it was more than equal after 28th day and from then on. The rising temperature ratio which occurs by simplicity insulation decreased as the replacement ratio of BS increased, but it increased by latent hydraulicity reaction at the latter half. The length ratio of autogenous shrinkage of OPC was 319×10-6, however it was shorter when the replacement ratio was 40% as showing 290×10-6.

  • PDF

A Study for Microstructure and Durability of Metakaolin Concrete (메타카올린 콘크리트의 미세 공극구조 및 내구성에 관한 연구)

  • Kim, Myung-Yu;Yang, Eun-Ik;Yang, Joo-Kyoung;Park, Hae-Geun;Chun, Sang-Eun;Lee, Myeong-Sub
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.417-420
    • /
    • 2008
  • The requirement for durability of concrete is increasing recently as a large-scale concrete structure is built. For this reason, the concern about high-durable concrete is being high. Recently, metakaoline to be profitable in economical aspect as well as to have strength and durability of level similar to silica fume is evaluated highly as new admixture. In this study, the scaling, the drying shrinkage, the chloride resistance and the air-void structure are compared for both metakaolin and silica fume concrete. According to the results, the replacement of metakaoline improved the resistance of chloride penetration, freezing and thawing in concrete. On the other hand, as metakaolin was replaced to 10%, it was similar level with OPC in the property of scaling. It was showed that replacement of only metakaoline was similar with OPC in the drying shrinkage. However, MS5 reduced the drying shrinkage about 10%. In conclusion, replacement of the metakaoline 10% is the most excellent performance in terms of durability of concrete.

  • PDF

Effect of Types of Accelerators and Replacement Levels of GGBFS on the Performance of Shotcrete Mortars (숏크리트 모르타르의 성능에 대한 급결제 종류 및 고로슬래그 미분말 대체율의 영향)

  • Lee, Seung Tae;Kim, Seong Soo;Kim, Dong Gyu;Park, Kwang Pil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.76-84
    • /
    • 2013
  • In this study, some engineering properties of OPC and GGBFS shotcrete mortars with alkali-free or aluminate accelerator were experimentally examined. As a result, GGBFS mortars with alkali-free accelerator were significantly similar to OPC mortars with same accelerator with respect to both setting time and compressive strength. Comparatively, GGBFS mortars with aluminate accelerator showed a good performance with an increased replacement of GGBFS. Furthermore, when replaced with GGBFS over 50%, the mortars exhibited superior performances of electrical resistivity and chloride ions penetration resistance. Accordingly, it is suggested that GGBFS has a beneficial effect as shotcreting materials in the condition of proper replacement levels.

Chloride Penetration of Concrete Mixed with High Volume Fly Ash and Blast Furnace Slag (FA 및 BFS를 다량 혼입한 콘크리트의 염분침투성)

  • Park, Ki-Cheul;Lim, Nam-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • This study examined dynamic and characteristics and chloride penetration of concrete mixed with large amount of FA and BFS, which are considered for positive application to construction fields with purpose of long-tern durability of concrete structures. As a result of strength test on FA and BFS, FA concrete showed higher increase of strength compared to OPC, when FA4000 and FA5000 were mixed 30%, respectively. For BFS concrete, those mixed with 30% and 50% of BFS8000, respectively, showed higher or equivalent strength compare to OPC. As a result of test of chloride penetration on FA and BFS, diffusion coefficients of concrete mixed with 30% FA4000 and FA5000, respectively, showed to restrain average 6.5% of diffusion coefficient compared to OPC. And in case of BFS concrete, those mixed with BFS6000 and BFS8000, restrained diffusion of chloride ions 253% and 336%, respectively, compared to OPC. Therefore, Mixing 50% of BFS was most efficient in order to maximize restraint of chloride penetration according to metathesis of large amount. For relation between compression strength and diffusion coefficient of FA and BFS concrete, as strength increased, diffusion coefficient decreased. In this study, when mixing FA and BFS to concrete for long-run durability and restraint against chloride penetration, for FA, mixing it to concrete with less or equivalent 30% of replacement rate was most efficient. And for BFS, as fineness was higher and mixing it to concrete with less or equivalent 50% of replacement rate, there were results of higher strength compared to OPC and more efficient restraint of chloride ions.

The Self-healing and Ageing Effect of OPC-GGBFS Cement in Sea-water and Tap-water (해수와 담수에서 OPC-GGBFS 시멘트의 자기치유와 재령효과)

  • Kim, Tae-Wan;Kang, Choonghyun
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.11-21
    • /
    • 2017
  • The paper presents experimental results of self-healing effects of OPC-GGBFS paste with cracked and uncracked specimens. The self-healing of cracked specimens is processes of crack closing with re-hydration of unhydrated in crack surface. The OPC paste with GGBFS replacement ratios of 0%, 10%, 20% and 30% were prepared having a constant water-binder ratios of 0.5. The OPC-GGBFS paste specimens immersed in tap-water and sea-water. The temperature of tap and sea-water was $5^{\circ}C$, $15^{\circ}C$ and $25^{\circ}C$. The cracked specimens after deterioration were immersed for 60 days. The relationship between self-healing effect and age-effect was calculate based upon the experimental results. The self-healing effect was measured in ultrasonic pulse velocity (UPV) before and after loading. When the relative change rate of UPV is increases with the increase in GGBFS replacement ratios. Moreover, the self-healing effect is increased with the temperature of tap-water is increase. But the cracked specimens immersed in sea-water was unclear effects of different temperature. Furemore, most of the healing for OPC-GGBFS specimens immersed in tap-water and sea-water occurred during the first 30 days. The self-healing effect until 30 days is higher than that the age-effect. After 30 days, self-effect and age-effect was largely decreases. SEM/EDS analysis of crack on the surface of the specimens in tap-water were covered with aragonite, and sea-water were covered with brucite.