• Title/Summary/Keyword: OPC(optical particle counter)

Search Result 29, Processing Time 0.025 seconds

A Study of Response Characteristics and False Counts in Optical Particle Counter (광학 입자 계수기의 응답특성 및 오계수에 관한 연구)

  • 안강호;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.547-554
    • /
    • 1992
  • Response characteristics and false counts of laser and white light optical particle counters (OPC) have been studied as a function of particle size using monodisperse polystylen laterx (PSL) particles. Theoretical light scattering calculations for He-Ne laser based counter have been compared with the experimental results and thus good agreements have been found. The light scattering intensity in monochromatic light shows an oscillatory character for the transparent and spherical particles of PSL due to Mie resonance. Because of this effect, the response of the LAS-X OPC showed almost same responses in the diameter ranges of 0.4mu.m to 0.6mu.m and 0.7mu.m to 1.0mu.m for PSL particles. A laser optical particle counter with high flow rate applied for clean room has been studied to identify the noise sources. Three different manufacturer's clean room optical particle counters alos have been tested to measure the background noise level.

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC) (광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성)

  • Jung Chang-Hoon;Cho Yong-Sung;Lee Jong-Tae
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter (광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구)

  • Song, Hyunwoo;Kim, Taewook;Song, Soonho
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon (광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성)

  • Choi, B.C.;Iwasaka, Y.;Lim, J.C.;Jeong, S.B.;Kim, Y.S.;Dmitri, T.;Nagatani, T.;Yamada, M.;Kim, S.B.;Hong, G.M.;Lee, Y.G.;Yoo, H.J.
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001 (OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포)

  • 정창훈;전영신;최병철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

Diurnal Size Distributions of Black Carbon by Comparison of Optical Particulate Measurements - Part I (광학 입자 측정기 비교 측정에 의한 입경별 일평균 블랙카본 분석 - Part I)

  • Park, Da-Jeong;Lee, Kwang-Yul;Park, Kihong;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Optical particle sizer (OPS), optical particle counter (OPC), and aethalomter were deployed to measure the particle number concentrations from 0.3 to $10.0{\mu}m$ and black carbon (BC) concentrations. Comparisons of particle number concentrations measured by OPS and OPC were conducted to evaluate the performance of the each optical instrument at the Gwangju sampling site ($35.23^{\circ}N$, $126.84^{\circ}E$) for 14 days from Dec. 27 in 2014. Although a good correlation ($r^2=0.99$) between the OPS and OPC was observed for both the particle number and volume concentrations, different relationships by BC concentrations can be associated with the intensities by different light scattering angles. In addition, based on diurnal patterns of size distributions in 24 hr running correlation coefficient determination, BC concentrations were highly related to the particles less than $0.3{\mu}m$ observed in the morning traffic hour.

Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols (Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정)

  • Eun, Hee Ram;Lee, Hong Ku;Lee, Yang Woo;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

Applicability of Optical Particle Counters for Measurement of Airborne Pesticide Spray Drift (공기 중 농약 비산의 측정을 위한 광학 입자 측정기의 적용성 평가)

  • Kim, Rack-Woo;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.5
    • /
    • pp.79-87
    • /
    • 2019
  • With desires for safe food, there is growing concern that pesticide spray drift will expose people, plants, and the environment to pesticide residue and potential negative effects thereof. For highly efficient, safe spray application, technologies for measuring the spray drift should be developed and improved with some urgency. This study investigated the applicability of two optical particle counters (OPCs), which are mostly used to measure airborne particle mass concentration, for measurement of airborne pesticide spray drift. Experiments were conducted in a controlled laboratory and an ash tree orchard to evaluate the handiness and accuracy of two OPCs, OPC 1 and OPC 2. The experimental results indicated that the OPC 1 was better applicable to the measurement of spray drift in the field while the use of the OPC 2 was limited due to its narrow range of measurable droplet sizes. The readings of the OPC 1 produced highly accurate results ($R^2=0.9637$) compared to the actual spray drift. For better application of OPCs, this study suggests the OPCs should be positioned properly to inhale spray droplets of the appropriate size and concentration.