DOI QR코드

DOI QR Code

Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC)

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성

  • Jung Chang-Hoon (Department of Environmental Health, Kyungin Women's College) ;
  • Cho Yong-Sung (Indoor Environmental Research Board, National Institute of Environmental Research) ;
  • Lee Jong-Tae (Department of Health Management, Hanyang University)
  • 정창훈 (경인여자대학 환경보건과) ;
  • 조용성 (국립환경연구원 실내환경연구사업단) ;
  • 이종태 (한양대학교 보건관리학과)
  • Published : 2005.06.01

Abstract

The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

Keywords

References

  1. 전영신, 김지영, 최재천, 신도식, 1999, 황사시 서울과 안면도의 대기 중 에어로졸 수농도 특성, 한국대기환경학회지, 15(5), 575-586
  2. 김지영, 최병철, 2002, 한반도에서 측정된 에어러솔의 크기 분포와 지역별 특성, 한국기상학회지, 38(2), 95-104
  3. Seinfeld, J. H. and S. N. Pandis, 1998, Atmospheric Chemistry and Physics, Wiley, New York, USA
  4. Merill, J. T., M. Uematsu and R. Bleck, 1989, Meteorological analyses of long-range transport of mineral aerosol over the North Pacific, J. Geophys. Research, 94, 8584-8598 https://doi.org/10.1029/JD094iD06p08584
  5. 정용승, 김태군, 1991, 대기오염의 장거리 이동 사례연구: 황사, TSP, Sulphate의 발원지 추적, 한국대기보전학회지, 7(3), 197-202
  6. 윤용황, 1990, 한반도에 수송되는 황사의 특징에 관한 연구, 한국기상학회지, 26(2), 111-120
  7. Laden, F., L. M. Neas, D. W. Dockery and J. Schwartzm, 2000, Association of fine particulate matter from different sources with daily mortality in six US cities, Environ. Health Perspect., 108, 941-947 https://doi.org/10.2307/3435052
  8. Pekkanen, J., K. L. Timonen, J. Ruuskanen, A. Reponen and A. Mirme, 1997, Effects of ultrafine and fine particles in urban air on peak expiratory flow among children with asthmatic symptoms, Environ. Res., 74, 24-33 https://doi.org/10.1006/enrs.1997.3750
  9. Peters, A., H. E. Wichmann, T. Tuch, J. Heinrich and J. Heyder, 1997, Respiratory effects are associated with the number of ultrafine particles, Am. J. Respir. Crit. Care Med., 155, 1376-1383 https://doi.org/10.1164/ajrccm.155.4.9105082
  10. Whitby, K. T., 1978, The physical characteristics of sulfur aerosols, Atmos. Environ., 12, 135-159 https://doi.org/10.1016/0004-6981(78)90196-8
  11. Schutz, J. and R. Jaenicke, 1982, Particle number and mass distributions above 10-4cm radius in sand and aerosol of the Sahara desert, J. Appl. Meteor., 13, 863-870 https://doi.org/10.1175/1520-0450(1974)013<0863:PNAMDA>2.0.CO;2
  12. Wang, G., J. Huang, S. Gao and J. Wang, 2002, Measurements of PM10 and PM2.5 in urban area of Nanjing, China and the assessment of pulmonary deposition of particle mass, Chemosphere, 48, 689-695 https://doi.org/10.1016/S0045-6535(02)00197-2
  13. Zaizen, Y., M. Ikegami, K. Okada and Y. Makino, 1995, Aerosol concentration observed at Zhangye in China, J. Meteorological Society in Japan, 73, 891-897 https://doi.org/10.2151/jmsj1965.73.5_891
  14. 조희구, 1980, 서울의 대기 aerosol 입자 크기 분포에 관한 연구, 한국기상학회지, 16, 1-9
  15. 김필수, 김윤장, 이양호, 조숙현, 안승태, 1986, 도시대기 Aeroslo의 입자직경 0.01-1.0 ${\mu}$m 범위의 농도변화 특성, 한국대기보전학회지, 2, 41-50
  16. Chun, Y., J. Kim, J. C. Choi, K. O. Boo, S. N. Oh and M. Lee, 2001, Characteristic number size distribution of aerosol during Asian dust period in Korea, Atmos. Environ., 35, 2715-2721 https://doi.org/10.1016/S1352-2310(00)00404-0
  17. 유인경, 조석연, 2004, 인천 지역 미세언지의 입경 분포 특성에 관한 연구, 한국대기환경학회추계학술대회 논문집, 176-177
  18. 김영준, 이병욱, 정현록, 김민정, 김경원, 김신도, 한진석, 2004, 서울.인천 지역 시정장애 에어로졸의 광.화학적 특성, 한국대기환경학회 추계학술대회 논문집, 217-218
  19. 환경부, 2004, 대기환경 월보
  20. Chow, J. C., 1995, Measurement methods to determine compliance with ambient air quality standards for suspended particles, J. Air & Waste Manage. Assoc., 45, 320-382 https://doi.org/10.1080/10473289.1995.10467369
  21. 조용성, 이종태, 김윤신, 홍승철, 김호, 하은희, 박혜숙, 이보은, 2003, 서울시 대기오염과 일별 사망의 상관성에 관한 시계열적 연구(1998-2001년), 한국대기환경학회지, 19(6), 625-637
  22. 조용성, 이홍석, 김윤신, 이종태, 박진수, 2003, 서울 성동구 지역 미세먼지의 화학적 조성에 관한 연구, 한국환경과학회지, 12(6), 665-676 https://doi.org/10.5322/JES.2003.12.6.665
  23. 정창훈, 전영신, 최병철, 2003, OPC(광학적 입자계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포, 한국대기환경학회지, 19(5), 515-528
  24. Bohren, G. F. and D. R. Hoffman, 1983, Absorption and Scattering of Light by Small Particles, Wiley, New York, 296pp
  25. Friehmelt, R. and S. Heidenreich, 1999, Calibration of a white-light/$90^{\circ}$optical particle counter for 'Aerodynamic' size measurements-Experiments and calculations for spherical particles and quartz dust, J. Aerosol Sci., 30, 1271-1279 https://doi.org/10.1016/S0021-8502(99)00044-0
  26. Liu, Y. and H. Daum, 2000, The effect of refractive index on size distributions and light scattering coefficients derived from optical particle counters, J. Aerosol Sci., 31, 945-957 https://doi.org/10.1016/S0021-8502(99)00573-X

Cited by

  1. in Jeju Area vol.23, pp.3, 2014, https://doi.org/10.5322/JESI.2014.23.3.447