• Title/Summary/Keyword: OCT(Optical Coherence Tomography)

Search Result 140, Processing Time 0.031 seconds

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain

  • Lee, Sang-Won;Song, Hyun-Woo;Kim, Bong-Kyu;Jung, Moon-Youn;Kim, Seung-Hwan;Cho, Jae-Du;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2011
  • In this study, we demonstrated Fourier-domain/swept-source optical coherence tomography (FD/SS-OCT) at a center wavelength of 800 nm for in vivo human retinal imaging. A wavelength-swept source was constructed with a semiconductor optical amplifier, a fiber Fabry-Perot tunable filter, isolators, and a fiber coupler in a ring cavity. Our swept source produced a laser output with a tuning range of 42 nm (779 to 821 nm) and an average power of 3.9 mW. The wavelength-swept speed in this configuration with bidirectionality is 2,000 axial scans per second. In addition, we suggested a modified zero-crossing method to achieve equal sample spacing in the wavenumber (k) domain and to increase the image depth range. FD/SS-OCT has a sensitivity of ~89.7 dB and an axial resolution of 10.4 ${\mu}m$ in air. When a retinal image with 2,000 A-lines/frame is obtained, an acquisition speed of 2.0 fps is achieved.

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.

Early caries detection using optical coherence tomography: a review of the literature (광간섭단층촬영술을 이용한 치아우식증의 발견)

  • Park, Young-Seok;Cho, Byeong-Hoon;Lee, Seung-Pyo;Shon, Won-Jun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.367-376
    • /
    • 2011
  • Early detection of carious lesions increases the possibility of treatment without the need for surgical intervention. Optical coherence tomography (OCT) is an emerging three-dimensional imaging technique that has been successfully used in other medical fields, such as ophthalmology for optical biopsy, and is a prospective candidate for early caries detection. The technique is based on low coherence interferometry and is advantageous in that it is non-invasive, does not use ionizing radiation, and can render threedimensional images. A brief history of the development of this technique and its principles are discussed in this paper. There have been numerous studies on caries detection, which were mostly in vitro or ex vivo experiments. Through these studies, the feasibility of OCT for caries detection was confirmed. However, further research should be performed, including in vivo studies of OCT applications, in order to prove the clinical usefulness of this technique. In addition, some technological problems must be resolved in the near future to allow for the use of OCT in everyday practice.

Development of The Intraoperative Surgical Optical Coherence Tomography Probe (실시간 광단층 모니터링 안구 수술용 현미경 프로브 개발)

  • Kim, Kyung-Un;Lee, Chang-Ho;Jeong, Hyo-Sang;Han, Seung-Hoon;Kim, Hong-Kyun;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • Intraoperative surgical microscope is an essential surgical equipment. However, it has a restriction to classify the retina layers because of the contrast differences. To solve this problem, operators use surgical instrument such as an intraocular mirror. In this case, it has to amputate the patient's eye. In this study, we developed a probe the intraoperative surgical optical coherence tomography. We expect that the developed OCT probe can overcome the limit of OCT and be applied as a real-time surgical tool. In this paper, we demonstrate applicability of the probe through rabbit's experimentation.

Treatment of immune-mediated keratitis (IMMK) in dogs with immunosuppressants observed with spectral domain optical coherence tomography (SD-OCT)

  • Hyelin Kim ;Youngseok Jeong ;Eunji Lee;Kangmoon Seo ;Seonmi Kang
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.66.1-66.7
    • /
    • 2023
  • Two dogs presented with bilateral pattern-forming corneal opacity. Treatment with topical immunosuppressants was initiated after a complete ophthalmic examination. The response to treatment was assessed by analyzing serial images using slit-lamp biomicroscopy and spectral domain optical coherence tomography (SD-OCT). Both dogs responded to topical immunosuppressants; however, the lesions recurred once the treatment was abated or withdrawn. The most effective immunosuppressant in both dogs was 0.03% tacrolimus ointment. Early and continuous treatment with topical immunosuppressants may be necessary to improve corneal clarity and prevent scarring. SD-OCT could provide useful structural information regarding presumed immune-mediated keratitis and aid in monitoring treatment response.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

In vivo Optical Coherence Tomography Imaging of the Mesothelium Using Developed Window Models

  • Ahn, Yeh-Chan;Chae, Yu-Gyeong;Hwang, Sang Seok;Chun, Bong-Kwon;Jung, Maan Hong;Nam, Sung Jin;Lee, Hae-Young;Chung, Jae Min;Oak, Chulho;Park, Eun-Kee
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.69-73
    • /
    • 2015
  • The mesothelium is an essential lining for maintaining the normal homeostasis of the closed body cavity and a central component of pathophysiologic processes. The mesothelium has been known as the end target for asbestos which induces asbestos-related lung diseases. Malignant mesothelioma (MM) is a rare and fatal neoplasm predominantly due to asbestos exposure. Adaptation of an advanced and reliable technology is necessary for early detection of MM because it is difficult to diagnose this disease in its early stages. Optical coherence tomography (OCT) provides cross-sectional images of micro-tissue structures with a resolution of $2-10{\mu}m$ that can image the mesothelium with a thickness of ${\sim}100{\mu}m$ and, therefore, enable investigation of early development of MM. The mesothelium is typically located at the pleura and tunica vaginalis of the scrotum. In this study, we developed animal window models in the above two anatomical sites to visualize mesothelial layers within the mesothelium. OCT images at the two locations were also acquired.

The Development of Double Clad Fiber and Double Clad Fiber Coupler for Fiber Based Biomedical Imaging Systems

  • Ryu, Seon-Young;Choi, Hae-Young;Ju, Myeong-Jin;Na, Ji-Hoon;Choi, Woo-June;Lee, Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.310-315
    • /
    • 2009
  • We report the fabrication of double clad fiber (DCF) and DCF coupler, suitable for fiber based imaging systems requiring the dual-channel transmission. Unlike the conventional DCF which uses silica for both cladding layers, the proposed DCF uses a low-index polymer for its outer-cladding layer coated over the conventional silica inner-cladding layer. The DCF is drawn with a conventional SMF preform but a low-index polymer coating is used for both jacket and outercladding of the fiber. To achieve the cladding mode coupling, a DCF coupler is fabricated by simply twisting two pieces of the proposed DCF after removing the polymer-coating at contacting regions. A cladding mode coupling ratio of 30% was achieved with a contact length of 16 cm. The proposed DCF and DCF coupler were employed in a composite optical coherence tomography (OCT) and fluorescence spectroscopy (FS) system, and both OCT images and FS signal from a plant tissue are measured simultaneously.

A Case Report of Acute Angle Closure Glaucoma Patient Treated with Go-bang (고방(古方)을 통한 급성 폐쇄성 녹내장의 한방치험 1례)

  • Han gioen;Kang Eunjeong
    • The Journal of Korean Medicine
    • /
    • v.44 no.2
    • /
    • pp.170-180
    • /
    • 2023
  • Objectives: This is a case report on the treatment of one patient with acute angle-closure glaucoma using traditional Korean medicine. Methode: We assessed the progression of acute angle-closure glaucoma by analyzing Optical Coherence Tomography(OCT) results. Results: Acute angle closure glaucoma did not progress to OCT after treatment. Conculsion: We obtained results from OCT examinations indicating that the progression of acute angle-closure glaucoma had ceased after Korean herbal medicine treatment.