• 제목/요약/키워드: OCS

검색결과 188건 처리시간 0.03초

강체전차선로 이행구간 Heavy Simple Catenary 적용을 위한 압상량 고찰 (A Study on the Uplift for Applying of Heavy Simple Catenary System in a Overhead Rigid Conductor Rail Transition Section)

  • 김완일;박원찬;이재봉;김재문
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.688-694
    • /
    • 2018
  • The transition section of the overhead rigid conductor rail (ORCR) consists of a direct induction device and a limit point to prevent the power supply failure and failure of the electric railway vehicle pantograph due to the difference of the uplift in the catenary line. In T-Bar transition section, a twin simple catenary is mostly installed between the overhead catenary system (OCS) in the ground section and the ORCR in the underground section. In this paper, we compare and analyze the possibility of replacing the twin simple catenary with heavy simple catenary. The reliability of numerical analysis results was confirmed by comparing field test with numerical results. Comparing the numerical results of the twin simple catenary with the heavy simple catenary in the transition section, the difference uplift is 5.9[mm] on average. When applying heavy simple catenary instead of twin simple catenary, the slight difference of uplift can be compensated by adjusting the height of hanger-ear or support bracket.

u-Healthcare 서비스 환경에서의 통합의료정보시스템 구축방안 연구 (Integrated Medical Information System Implementation for the u-Healthcare Service Environment)

  • 석윤영;김석훈
    • 한국콘텐츠학회논문지
    • /
    • 제14권5호
    • /
    • pp.1-7
    • /
    • 2014
  • 최근 병원은 ICT기술을 접목한 고품질의 의료서비스를 제공하는 허브병원으로서의 기능을 수행하기 위해 병원의 정보화를 통하여 직무능력을 향상하고 경영자의 의사결정지원시스템을 통하여 고도화된 통합의료정보시스템을 구축하고 있다. 본 연구에서는 환자정보와 진료정보의 신속한 조회로 진료편의성을 극대화 할 수 있도록 통합의료정보시스템에 OCS(Order Communication System)시스템과 HIS(Hospital Information System)시스템을 연동하여 최적화된 맞춤형 모바일 헬스케어 진료환경을 설계하여 환자의 치료 및 진료를 신속하고 정확하게 수행할 수 있는 체계적인 의료시스템을 연구하였다.

임상간호사의 영상표시단말기 증후군 및 영향요인 (Factors influencing Video Display Terminal Syndrome in Clinical Nurses)

  • 권윤희
    • 한국간호교육학회지
    • /
    • 제22권4호
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

Novel Robust Structure and High k Dielectric Material for 90 nm DRAM Capacitor

  • Park, Y.K.;Y.S. Ahn;Lee, K.H.;C.H. Cho;T.Y. Chung;Kim, Kinam
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권2호
    • /
    • pp.76-82
    • /
    • 2003
  • The robust stack storage node and sufficient cell capacitance for high performance is indispensable for 90 nm DRAM capacitor. For the first time, we successfully demonstrated MIS capacitor process integration for 90 nm DRAM technology. Novel cell layout and integration technology of 90 nm DRAM capacitor is proposed and developed, and it can be extended to the next generation DRAM. Diamond-shaped OCS with 1.8 um stack height is newly developed for large capacitor area with better stability. Furthermore, the novel $Al_2O_3/HfO_2$ dielectric material with equivalent oxide thickness (EOT) of 25 ${\AA}$ is adopted for obtaining sufficient cell capacitance. The reliable cell capacitance and leakage current of MIS capacitor is obtained with ~26 fF/cell and < 1 fA/ceil by $Al_2O_3/HfO_2$ dielectric material, respectively.

250 km/h급 강체전차선로 설계파라미터 제시 (A Propose of Design Parameters for the Max. Speed of 250 km/h of Overhead Rigid Conductor System)

  • 이기원;조용현
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.740-744
    • /
    • 2017
  • Overhead Line is divided by two systems which are OCS (Overhead Catenary Line) and R-Bar (Overhead Rigid Conductor system). R-Bar has an advantage of maintenance and economic aspect comparing with OCS. R-Bar in Korea has developed for the max. speed of 120km/h, but it is evaluated up to the max. speed of 250 km/h in Europe. There are lots of mountains and underground sections in korea, it is really necessary to develop the R-Bar for a high-speed line. In the study, design parameters for the max. speed of 250 km/h of R-Bar was proposed. A bracket space, stiffness, and especially an installation tolerance of contact wire height at a bracket were considered as a parameter, and a dynamic behavior between a contact wire and pantograph was predicted by evaluated FEM simulation tool. The installation tolerance and bracket space are more important for the high-speed system. The proposed parameters was decided very conservative. Because the aerodynamic characteristics of a pantograph in tunnel is more severe than an open route and the simulation tool is not considered the such kind of aerodynamic characteristics.

Computed Radiography의 방사선종양학과로의 적용 (Computed Radiography applied to the Department of Radiation Oncology)

  • 홍성일;송종남;김영재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.547-550
    • /
    • 2011
  • 본 논문에서는 의료용 선형가속기를 이용하여 현재 시행하고 있는 정도관리 중 Gantry, Collimator Star Shot, Light vs. Radiation Field Accuracy, HDR QA(Dwell position accuracy)를 시행하여 PACS 상에 구현하였고 모니터 상에서 디지털 영상을 통한 QA가 가능한지 확인하였다. 또한, 현재 본원에서 사용 중인 OCS system과 연동하여 치료에 필요한 코드를 각각의 치료에 부과하여 네트워크로 연결, CR상에 입력한 Order가 나타나도록 하였으며, Planning System인 Pinacle과 PACS상의 지원 data 오류를 해결하여 PACS 상에서도 Planning 영상을 볼 수 있도록 하였다.

  • PDF

GIS용 광전류센서의 실시간 센서링 연구 (A study on the real time sensing of optical current sensor for GIS)

  • 김영민;지승욱;이광식;김민수;김정배;박원주
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.422-425
    • /
    • 2006
  • 본 연구는 도체주변에 감겨진 광섬유 코일에 따라 선형편광축이 자기장에 의해 회전하는 Faraday Effect를 이용한 GIS(Gas Insulated Switchgear,이하 GIS) 용 광 전류센서의 구성과 DAQ(Data Acquisition,이하 DAQ)보드를 장착한 PC를 이용하여 실시간 데이터 취득, 분석 그리고 저장을 동시에 수행하였다 광원은 1310[nm]의 레이저 다이오드를 이용하였다. 센서부는 GIS에 맞게 원형으로 제작하였고 $9/125[{\mu}m]$규격 단일모드의 일반 통신용 광섬유를 지름 31[cm]의 센서부 코어에 20[회] 감아 설치하였다. PC기반의 실시간 데이터 분석 프로그래밍은 NI사의 Labview를 이용하여 코딩하였으며 PD(Photo Diode,이하 PD)의 전기적인 신호는 터미널 블록을 거쳐 NI사의 16bit DAQ M시리즈를 이용하여 수집되어진다. 직접 코딩한 프로그램을 이용하여 $700A\sim1400A$ 측정한 출력값 선형적인 증가추세를 보여주었다. 또한 OCS(Oscilloscope,이하 OCS)를 이용한 측정시스템과의 출력신호 및 정밀도를 비교 검토하였다. 그리고 Labview에서 지원하는 Web Tool기능을 이용하여 Web기반의 원거리 측정에서도 안정된 출력을 보여주었다.

  • PDF

고분자 표면 배향을 이용한 광학 보상 퍼짐 셀의 특성 향상 연구 (Study on Electro-optical Characteristics in the Optically Compensated Splay Cell using Polymer Surface Alignment)

  • 김성수;황성진;황성한;이명훈;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.424-425
    • /
    • 2007
  • We have studied the optically compensated splay mode using reactive mesogen (RM) monomer to reduce setting voltage and phase transition time from initial bend to splay state. When the OCS cell has low pretilt angle close to $45^{\circ}C$, OCS state can be formed easily. The low pretilt angle was formed through the polymerization of UV curable reactive RM monomer at the surfaces. In this way, reorientation of the LC is well defined and thus the device shows better performances in setting voltage and phase transition time.

  • PDF

Histological classification of canine ovarian cyst types with reference to medical history

  • Knauf, Yvonne;Kohler, Kernt;Knauf, Sascha;Wehrend, Axel
    • Journal of Veterinary Science
    • /
    • 제19권6호
    • /
    • pp.725-734
    • /
    • 2018
  • Ovaries of 21 bitches presented with gynecopathies were surgically removed and histologically examined. Standard histological, as well as immunohistochemical, classification of 193 cystic structures resulted in the classification of 72 cysts of subsurface epithelial structures (SES), 61 follicular cysts (FCs), 38 cystic rete ovarii (CRO), 13 lutein cysts (LCs), and 9 non-classifiable cysts (NCCs). In addition to the histological classification, results were interpreted according to subject medical history, clinical examination outcome, and macroscopic observations during ovariohysterectomy. Dogs with ovarian cysts (OCs) and associated reproductive perturbations were mostly nulliparous, of large breed, and had an average of $9.5{\pm}3$ years. Prolonged or shortened inter-estrus intervals of past heats, however, seemed to be relatively low-risk factors for the development of OCs in dogs. Furthermore, we provide histological observations of a rarely seen canine LC including a degenerated oocyte in the central cavity.

Osteoclasts in the Inflammatory Arthritis: Implications for Pathologic Osteolysis

  • Youn-Kwan Jung;Young-Mo Kang;Seungwoo Han
    • IMMUNE NETWORK
    • /
    • 제19권1호
    • /
    • pp.2.1-2.13
    • /
    • 2019
  • The enhanced differentiation and activation of osteoclasts (OCs) in the inflammatory arthritis such as rheumatoid arthritis (RA) and gout causes not only local bone erosion, but also systemic osteoporosis, leading to functional disabilities and morbidity. The induction and amplification of NFATc1, a master regulator of OC differentiation, is mainly regulated by receptor activator of NF-κB (RANK) ligand-RANK and calcium signaling which are amplified in the inflammatory milieu, as well as by inflammatory cytokines such as TNFα, IL-1β and IL-6. Moreover, the predominance of CD4+ T cell subsets, which varies depending on the condition of inflammatory diseases, can determine the fate of OC differentiation. Anti-citrullinated peptide antibodies which are critical in the pathogenesis of RA can bind to the citrullinated vimentin on the surface of OC precursors, and in turn promote OC differentiation and function via IL-8. In addition to adaptive immunity, the activation of innate immune system including the nucleotide oligomerization domain leucine rich repeat with a pyrin domain 3 inflammasome and TLRs can regulate OC maturation. The emerging perspectives about the diverse and close interactions between the immune cells and OCs in inflammatory milieu can have a significant impact on the future direction of drug development.