• Title/Summary/Keyword: Nyquist Sampling Theorem

Search Result 9, Processing Time 0.029 seconds

Characteristics of One Step Advanced Discrete Time D-Control with Time Delay in Noncolocated Flexible System (비병치 유연계의 시간지연 이산제어에서 한스텝선행 미분제어기의 특성)

  • Kang, Min-Sig
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1678-1685
    • /
    • 1993
  • This paper considers a time delay control of noncolocated flexible mechanical systems in discrete time domain. A stability criterion suggested in the previous paper is,extended in the consideration of infinite mode property of flexible systems and finite control sampling frequency. Based on the stability criterion, the one step advanced discrete time derivative control is suggested, which can stabilize infinite number of modes of a flexible system. The sensitivity analysis shows the robustness of the one step advanced control to the system parameter uncertainties and time delay errors. Application to a simply supported beam verifies the extended stability criterion and the effectiveness of the one step advanced D-control.

Real-Time All-Optical Three-Dimensional Image Projector

  • Jang, Ju-Seog;Javidi, Bahram
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.285-288
    • /
    • 2002
  • We propose the use of synchronously moving micro-optics (lenslet arrays) for image pickup and display in three-dimensional integral imaging to overcome the upper resolution limit imposed by the Nyquist sampling theorem. With the proposed technique, we present an all-optical three-dimensional integral imaging projector. An optically addressed spatial light modulator is used, which potentially provides better image resolution than the conventional CCD and liquid crystal display pair. We present experimental results using a liquid crystal light valve.

  • PDF

A Derivation of the Accuracy Relationship between the Reconstruction of 3D Object Coordinates and the Number of Closed Curves (폐곡선의 수에 따른 3차원 물체의 좌표 복원 정확도 관계 도출)

  • Lee, Deokwoo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1004-1013
    • /
    • 2017
  • This paper presents a relationship between the number of curves and geometric parameters of a 3D object. Once the relationship is established, the number of closed curves that can reliably represent 3D object is derived. Inspired by Shannon-Nyquist Sampling Theorem, in this paper, approach for sampling rate (defined as the minimum number of curves) for 3D reconstruction is proposed. The relationship is straightforward, is suitable for application to 3D object overlaid with closed-continuous curves, and can achieve efficient 3D reconstruction system in practice. To substantiate the proposed approach, simulation results are provided and the results show that the number of curves can be decreased without loss of generality of characteristics of a target 3D object.

Compressive Sensing: From Theory to Applications, a Survey

  • Qaisar, Saad;Bilal, Rana Muhammad;Iqbal, Wafa;Naureen, Muqaddas;Lee, Sungyoung
    • Journal of Communications and Networks
    • /
    • v.15 no.5
    • /
    • pp.443-456
    • /
    • 2013
  • Compressive sensing (CS) is a novel sampling paradigm that samples signals in a much more efficient way than the established Nyquist sampling theorem. CS has recently gained a lot of attention due to its exploitation of signal sparsity. Sparsity, an inherent characteristic of many natural signals, enables the signal to be stored in few samples and subsequently be recovered accurately, courtesy of CS. This article gives a brief background on the origins of this idea, reviews the basic mathematical foundation of the theory and then goes on to highlight different areas of its application with a major emphasis on communications and network domain. Finally, the survey concludes by identifying new areas of research where CS could be beneficial.

Application of Biosignal Data Compression for u-Health Sensor Network System (u-헬스 센서 네트워크 시스템의 생체신호 압축 처리)

  • Lee, Yong-Gyu;Park, Ji-Ho;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.352-358
    • /
    • 2012
  • A sensor network system can be an efficient tool for healthcare telemetry for multiple users due to its power efficiency. One drawback is its limited data size. This paper proposed a real-time application of data compression/decompression method in u-Health monitoring system in order to improve the network efficiency. Our high priority was given to maintain a high quality of signal reconstruction since it is important to receive undistorted waveform. Our method consisted of down sampling coding and differential Huffman coding. Down sampling was applied based on the Nyquist-Shannon sampling theorem and signal amplitude was taken into account to increase compression rate in the differential Huffman coding. Our method was successfully tested in a ZigBee and WLAN dual network. Electrocardiogram (ECG) had an average compression ratio of 3.99 : 1 with 0.24% percentage root mean square difference (PRD). Photoplethysmogram (PPG) showed an average CR of 37.99 : 1 with 0.16% PRD. Our method produced an outstanding PRD compared to other previous reports.

Front-End Design for Underwater Communication System with 25 kHz Carrier Frequency and 5 kHz Symbol Rate (25kHz 반송파와 5kHz 심볼율을 갖는 수중통신 수신기용 전단부 설계)

  • Kim, Seung-Geun;Yun, Chang-Ho;Park, Jin-Young;Kim, Sea-Moon;Park, Jong-Won;Lim, Young-Kon
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.166-171
    • /
    • 2010
  • In this paper, the front-end of a digital receiver with a 25 kHz carrier frequency, 5 kHz symbol rate, and any excess-bandwidth is designed using two basic facts. The first is known as the uniform sampling theorem, which states that the sampled sequence might not suffer from aliasing even if its sampling rate is lower than the Nyquist sampling rate if the analog signal is a bandpass one. The other fact is that if the sampling rate is 4 times the center frequency of the sampled sequence, the front-end processing complexity can be dramatically reduced due to the half of the sampled sequence to be multiplied by zero in the demixing process. Furthermore, the designed front-end is simplified by introducing sub-filters and sub-sampling sequences. The designed front-end is composed of an A/D converter, which takes samples of a bandpass filtered signal at a 20 kHz rate; a serial-to-parallel converter, which converts a sampled bandpass sequence to 4 parallel sub-sample sequences; 4 sub-filter blocks, which act as a frequency shifter and lowpass filter for a complex sequence; 4 synchronized switches; and 2 adders. The designed front-end dramatically reduces the computational complexity by more than 50% for frequency shifting and lowpass filtering operations since a conventional front-end requires a frequency shifting and two lowpass filtering operations to get one lowpass complex sample, while the proposed front-end requires only four filtering operation to get four lowpass complex samples, which is equivalent to one filtering operation for one sample.

Reducing Power Consumption of Wireless Capsule Endoscopy Utilizing Compressive Sensing Under Channel Constraint

  • Saputra, Oka Danil;Murti, Fahri Wisnu;Irfan, Mohammad;Putri, Nadea Nabilla;Shin, Soo Young
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2018
  • Wireless capsule endoscopy (WCE) is considered as recent technology for the detection cancer cells in the human digestive system. WCE sends the captured information from inside the body to a sensor on the skin surface through a wireless medium. In WCE, the design of low-power consumption devices is a challenging topic. In the Shannon-Nyquist sampling theorem, the number of samples should be at least twice the highest transmission frequency to reconstruct precise signals. The number of samples is proportional to the power consumption in wireless communication. This paper proposes compressive sensing as a method to reduce power consumption in WCE, by means of a trade-off between samples and reconstruction accuracy. The proposed scheme is validated under channel constraints, expressed as the realistic human body path loss. The results show that the proposed scheme achieves a significant reduction in WCE power consumption and achieves a faster computation time with low signal error reconstruction.

Modeling of the friction in the tool-workpiece system in diamond burnishing process

  • Maximov, J.T.;Anchev, A.P.;Duncheva, G.V.
    • Coupled systems mechanics
    • /
    • v.4 no.4
    • /
    • pp.279-295
    • /
    • 2015
  • The article presents a theoretical-experimental approach developed for modeling the coefficient of sliding friction in the dynamic system tool-workpiece in slide diamond burnishing of low-alloy unhardened steels. The experimental setup, implemented on conventional lathe, includes a specially designed device, with a straight cantilever beam as body. The beam is simultaneously loaded by bending (from transverse slide friction force) and compression (from longitudinal burnishing force), which is a reason for geometrical nonlinearity. A method, based on the idea of separation of the variables (time and metric) before establishing the differential equation of motion, has been applied for dynamic modeling of the beam elastic curve. Between the longitudinal (burnishing force) and transverse (slide friction force) forces exists a correlation defined by Coulomb's law of sliding friction. On this basis, an analytical relationship between the beam deflection and the sought friction coefficient has been obtained. In order to measure the deflection of the beam, strain gauges connected in a "full bridge" type of circuit are used. A flexible adhesive is selected, which provides an opportunity for dynamic measurements through the constructed measuring system. The signal is proportional to the beam deflection and is fed to the analog input of USB DAQ board, from where the signal enters in a purposely created virtual instrument which is developed by means of Labview. The basic characteristic of the virtual instrument is the ability to record and visualize in a real time the measured deflection. The signal sampling frequency is chosen in accordance with Nyquist-Shannon sampling theorem. In order to obtain a regression model of the friction coefficient with the participation of the diamond burnishing process parameters, an experimental design with 55 experimental points is synthesized. A regression analysis and analysis of variance have been carried out. The influence of the factors on the friction coefficient is established using sections of the hyper-surface of the friction coefficient model with the hyper-planes.

Design of a SQUID Sensor Array Measuring the Tangential Field Components in Magnetocardiogram (심자도용 접선성분자장 측정방식 스퀴드 센서열 설계)

  • Kim K.;Lee Y. H;Kwon H;Kim J. M;Kim I. S;Park Y. K;Lee K. W
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.56-63
    • /
    • 2004
  • We consider design factors for a SQUID sensor array to construct a 52-channel magnetocardiogram (MCG) system that can be used to measure tangential components of the cardiac magnetic fields. Nowadays, full-size multichannel MCG systems, which cover the whole signal area of a heart, are developed to improve the clinical analysis with high accuracy and to provide patients with comfort in the course of measurement. To design the full-size MCG system, we have to make a compromise between cost and performance. The cost is involved with the number of sensors, the number of the electronics, the size of a cooling dewar, the consumption of refrigerants for maintenance, and etc. The performance is the capability of covering the whole heart volume at once and of localizing current sources with a small error. In this study, we design the cost-effective arrangement of sensors for MCG by considering an adequate sensor interval and the confidence region of a tolerable localization error, which covers the heart. In order to fit the detector array on the cylindrical dewar economically, we removed the detectors that were located at the corners of the array square. Through simulations using the confidence region method, we verified that our design of the detector array was good enough to obtain whole information from the heart at a time. A result of the simulation also suggested that tangential-component MCG measurement could localize deeper current dipoles than normal-component MCG measurement with the same confidence volume; therefore, we conclude that measurement of the tangential component is more suitable to an MCG system than measurement of the normal component.

  • PDF