• 제목/요약/키워드: Nusselt-Reynolds correlations

검색결과 36건 처리시간 0.02초

미세유로의 단상 유동 및 열전달에 대한 실험적 연구 (Experimental Studies on Single Phase Flow and Heat Transfer in Microchannels)

  • 김병주;김건일
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.795-801
    • /
    • 2008
  • An experimental study has been performed on the single phase flow and convective heat transfer in trapezoidal microchannels. The microchannel was about $270{\mu}m$ wide, $800{\mu}m$ deep. and 7 mm long, which might ensure hydrodynamically fully-developed laminar flow at a low Reynolds number. The experiments were conducted with R1l3 and water, with the Reynolds number ranging from approximately 30 to 5000 for friction factor and 30 to 700 for the Nusselt number. Friction factors in laminar are found to be in good agreement with the predictions of existing correlation suggesting that a conventional analysis approach can be employed in predicting flow friction behavior in microchannels. However turbulent friction factors are hardly predictable by the existing correlations. The experimental results show that the Nusselt number is not a constant but increases almost linearly with the Reynolds number even the flow is fully developed (Re < 100). The dependence of the Nusslet number on the Reynolds number is contradictory to the conventional theory. At a Reynolds number greater than 100, the Nusselt number increases slowly with the Reynolds number, where thennally developing flow is responsible for the increase of the Nusselt number with the Reynolds number.

미세유로를 갖는 납작관의 열·유동 해석 (Thermal and Flow Analysis of the Flat Tube with Micro-Channels)

  • 정길완;이관수;김우승
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.978-986
    • /
    • 1999
  • In this study, the general thermal and flow characteristics of flat tube with micro-channels has been studied and the correlation of Nusselt number and friction factor is proposed. The optimal flat tube geometry is determined by optimal design process. It is assumed to be a three dimensional laminar flow in the analysis of thermal and flow characteristics. The periodic boundary condition is applied since the geometry of flat tube with micro-channels shows uniform cross-section in primary flow direction. Local Nusselt number is examined for thermal characteristics of each membrane, and module average Nusselt number and friction factor are calculated to determine the characteristics of the heat transfer and pressure drop in overall flat tube with microchannels. The correlations between Nusselt number and friction factor are given by Reynolds number, aspect ratio of membranes, and the width of flat tube. ALM (Augmented Lagrangian Multiplier) method is applied to the correlations to determine an optimal shape of flat tube. It is shown that the optimal aspect ratio of flat tube is approximately 1.0, irrespective of the width of flat tube and Reynolds number.

경사진 벽부착 제트의 열전달 특성에 대한 연구 (An Investigation on Heat transfer Characteristics of Inclined Wall Attaching Offest jet)

  • 심재경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.200-209
    • /
    • 1998
  • Experiments have been conducted to determine heat transfer characteristics for a two-dimen-sional turbulent wall attaching offset jet at different oblique angles to a flat surface. The local Nusselt number distributions were measured using liquid crystal as a temperature sensor. Wall static pressure coefficient profiles were measured at the Reynolds number Re 53200(based on the nozzle width, D) the offset ratio H/D from 2.5 to 10 and the oblique angle a from $0^{\circ}$, to $40^{\circ}$ It is observed that the maximum Nusselt number point occurs slightly upstream of time-averaged reattachment point for all oblique angles. The correlations between the maximum Nusselt number and Reynolds number offset ration and oblique angle are presented.

  • PDF

2차원 난류 벽부착제트의 대류열전달 특성 (Convective heat transfer characteristics of a two-dimensional turbulent wall attaching offset jet)

  • 윤순현;이대희;송흥복;김대성
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3304-3312
    • /
    • 1996
  • An experimental study on the convective heat transfer characteristics was performed for a two-dimensional wall attaching offset jet(WAOJ). Thermochromic liquid crystal was used to measure the plate wall temperature. The Nusselt number was measured for Reynolds numbers from 6, 500 to 39, 000, and the offset ratios from 0.5 to 15. The maximum Nusselt number point coincides with the time-averaged reattachment point and Nusselt number decreases monotonically after the jet reattaches on the wall. In the recirculation region Nusselt number minimize near the upstream corner and then increases as X/D decreases to vanishes. This suggests the existence of secondary vortices, causing an additional mixing of the flow in the corner. The correlations between the local Nusselt number and Reynolds number, Re, offset ratio, H/D, and streamwise distance, X/D are presented.

직접분사식 디젤엔진 실린더헤드의 온도 및 열응력 분포해석(PART I) (Analysis of Temprature and Thermal Stress Distribution of a DI Diesel Engine Cylinder Head(PART I))

  • 이진호;이교승;장경준
    • 한국자동차공학회논문집
    • /
    • 제4권5호
    • /
    • pp.187-196
    • /
    • 1996
  • In this study, 3-dimensional finite element model of a diesel engine cylinder head was made to accomplish heat transfer analysis and also thermal stress and deformation analysis. Heat release analysis and Nusselt-Reynolds correlations were applied to determine the convective boundary conditions which are required for heat transfer analysis to calculate temperature distribution. Thermal stress distribution was also investigated from heat transfer analysis results. Steady state temperature and heat flux were measured by using K-type thermocouples and then compared with numerical results to give a guarantee for the propriety of numerical analyses.

  • PDF

관군 배열에서의 종간 간격이 열전달에 미치는 영향에 대한 수치 해석적 연구 (NUMERICAL ANALYSIS FOR LONGITUDINAL PITCH EFFECT ON TUBE BANK HEAT TRANSFER)

  • 이동균;안준;신승원
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.39-44
    • /
    • 2012
  • In this study, a longitudinal pitch effect on in-line tube bank heat transfer has been analyzed numerically. To verify the accuracy of the solver model and boundary conditions, global Nusselt number(Nu) and pressure drop across the 2 row tube bank are compared with the existing experimental correlations under 500 ~ 2,000 Reynolds number(Re) range. By changing transverse pitch($S_T$) or longitudinal pitch($S_L$) separately in tube bank, we're trying to identify the each effect on heat transfer. We found that the effect of transverse pitch can be accounted for Reynolds number evaluated with maximum velocity($V_{max}$) at the smallest flow area similar to most existing correlations. Variation of the longitudinal pitch($S_L$) has a greater impact on the heat transfer compared to the transverse pitch($S_T$). Overall Nusselt number increases with larger longitudinal pitch($S_L$), however individual Nusselt number of the tube row has significant difference after the first row.

평판 핀 튜브 열교환기의 공기측 강제대류 열전달계수에 대한 실험 및 수치계산 (Experimental Measurement and Numerical Computation on the Air-Side Forced Convective Heat Tranfer Coefficient in Plate Fin-Tube Exchangers)

  • 윤영환;팽진기;윤건식
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.729-737
    • /
    • 2006
  • Air-side forced convective heat transfer of a plate fin-tube heat exchanger is investigated by experimental measurement and numerical computation. The heat exchanger consists of staggered arrangement of refrigerant pipes of 10.2 m diameter and the pitch of fins is 3.5 m. In the experimental study, the forced convective heat transfer is measured at Reynolds number of 1082, 1397, 1486, 1591 and 1649 based on diameter of refrigerant piping and mean velocity. Average Nusselt number for the convective heat transfer coefficient is also computed for the same Reynolds number by commercial software of STAR-CD with standard $k-{\varepsilon}$ turbulent model. It is found that the relative errors of average Nusselt numbers between experimental and numerical data are less than 6 percentage in Reynolds number of $1082{\sim}1649$. The errors between experiment and other correlations are ranged from 7% to 32.4%. But the correlation of Kim at al is closest to the experimental data within 7% of the relative error.

마이크로휜관 내 단상 냉각 유동 열전달 및 압력 강하 특성에 관한 실험적 연구 (Experiments on Single Phase Cooling Heat Transfer and Pressure Drop Characteristics in Microfin Tubes)

  • 이규정;한동혁
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.231-239
    • /
    • 2002
  • Experiments on the single phase cooling heat transfer and pressure drop with microfin tubes were performed using water as a test fluid. Experimental data were obtained in the range of Reynolds number 3000 ~40000 and Prandtl number 4-6. The data of microfin tubes presented the characteristics of rough surface tube in pressure drop and heat transfer Experimental data were compared with the heat transfer and friction factor correlations of smooth tubes. Heat transfer enhancements of microfin tubes were lower than pressure drop penalty factors. The helix angle is more significant parameter in both of the pressure drop and heat transfer than the relative roughness. The correlations of Nusselt number and friction factor were suggested for the tested microfin tubes. Maximum deviations between correlations and experimental data were within $\pm15$% for Nusselt number and $\pm10$% for friction factor.

과도액정 기법을 이용한 오목표면 경사각도에 따른 난류 충돌 제트의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Turbulent Round Jet Impinge on the Inclined Concave Surface Using Transient Liquid Crystal Method)

  • 임경빈;이창희;이상훈
    • 대한기계학회논문집B
    • /
    • 제30권7호
    • /
    • pp.656-662
    • /
    • 2006
  • The effects of concave hemispherical surface with inclined angle on the local heat transfer from a turbulent round jet impinging were experimentally investigated using transient liquid crystal method. This method suddenly exposes a preheated wall to an impinging jet and then the video system records the response of liquid crystals for the measurement of the surface temperature. The Reynolds numbers were used 11000, 23000 and 50000, nozzle-to-surface distance ratio from 2 to 10 and the surface angles $\alpha=0^{\circ},\;15^{\circ},\;30^{\circ}\;and\;40^{\circ}$. Correlations of the stagnation point Nusselt number according to Reynolds number, jet-to-surface distance ratio and dimensionless surface angle are investigated. In the stagnation point, in term of $Re^n$, n ranges from 0.43 in case of $2{\leq}L/d\leq6$ to 0.45 in case of $6. The maximum Nusselt number occurs in the direction of upstream. The displacement of the maximum Nusselt number from the stagnation point increases with increasing surface angle or decreasing nozzle-to-surface distance. The maximum displacement is about 0.7 times of the jet nozzle diameter.

Heat Transfer Correlation to Predict the Evaporation of a Water Droplet in Superheated Steam during Reflood Phase of a LOCA

  • Kim, Yoo;Ban, Chang-Hwan
    • 에너지공학
    • /
    • 제9권3호
    • /
    • pp.261-268
    • /
    • 2000
  • A heat transfer correlation to predict the vaporization of a water droplet in highly superheated steam during a loss-of-coolant accident(LOCA) of a nuclear power plant is provided. Vaporization of liquid fuel or water droplets in superheated air or steam and subsequent interface heat transfer between a liquid droplet and superheated gas is typically correlated by way of a Nusselt number as a function of Reynolds number, Prantl number, and in some cases including mass transfer number. Presently available correlations and experimental data of the evaporation of liquid droplets in air or steam are analyzed and a new Nusselt number correlation is proposed taking Schmidt number into consideration in order to account for binary diffusion of the vapor as well, Nu$\_$f/(1+B)$\^$0.7/=2+0.53Sc$\_$f/$\^$-1/5/Re$\_$M/$\^$$\sfrac{1}{2}$/Pr$\_$f/$\^$$\sfrac{1}{3}$/ for which properties are evaluated at film condition except the density of Reynolds number evaluated at ambient condition. Diverse correlations for various combinations of liquid and gas species are put into single equation. The blowing correction factor of (1+B)$\^$0.7/ is confirmed appropriate, and a criterion to distinguish so-called high- and low-temperature condition of ambient gas is set forth.

  • PDF