• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.037 seconds

Scintigraphic Evaluation of Gastrointestinal Motility Disorders (기능성 위장관 질환에서 핵의학 검사의 역할)

  • Choe, Jae-Gol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes alter therapy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy.

  • PDF

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

A Study on the Ordered Subsets Expectation Maximization Reconstruction Method Using Gibbs Priors for Emission Computed Tomography (Gibbs 선행치를 사용한 배열된부분집합 기대값최대화 방출단층영상 재구성방법에 관한 연구)

  • Im, K. C.;Choi, Y.;Kim, J. H.;Lee, S. J.;Woo, S. K.;Seo, H. K.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.441-448
    • /
    • 2000
  • 방출단층영상 재구성을 위한 최대우도 기대값최대화(maximum likelihood expectation maximization, MLEM) 방법은 영상 획득과정을 통계학적으로 모델링하여 영상을 재구성한다. MLEM은 일반적으로 사용하여 여과후역투사(filtered backprojection)방법에 비해 많은 장점을 가지고 있으나 반복횟수 증가에 따른 발산과 재구성 시간이 오래 걸리는 단점을 가지고 있다. 이 논문에서는 이러한 단점을 보완하기 위해 계산시간을 현저히 단축시킨 배열된부분집합 기대값최대화(ordered subsets expectation maximization. OSEM)에 Gibbs 선행치인 membrance (MM) 또는 thin plate(TP)을 첨가한 OSEM-MAP (maximum a posteriori)을 구현함으로써 알고리즘의 안정성 및 재구성된 영상의 질을 향상시키고자 g나다. 실험에서 알고리즘의 수렴시간을 가속화하기 위해 투사 데이터를 16개의 부분집합으로 분할하여 반복연산을 수행하였으며, 알고리즘의 성능을 비교하기 위해 소프트웨어 모형(원숭이 뇌 자가방사선, 수학적심장흉부)을 사용한 영상재구성 결과를 제곱오차로 비교하였다. 또한 알고리즘의 사용 가능성을 평가하기 위해 물리모형을 사용하여 PET 기기로부터 획득한 실제 투사 데이터를 사용하였다.

  • PDF

Comparative study of 2-nitroimidazole-fluorophore-conjugated derivatives with pimonidazole for imaging tumor hypoxia

  • Seelam, Sudhakara Reddy;Hong, Mi Kyung;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.101-112
    • /
    • 2019
  • Herein, 2-nitroimidazole-fluorophore conjugates were synthesized by linking 2-nitroimidazole and FITC or RITC via thiourea bonds. The prepared derivatives were stable for 2 h in Dulbecco's modified Eagle's medium (DMEM) at 37 ℃. The novel conjugates were studied for their in vitro uptake under hypoxic conditions using U87MG and CT-26 cell lines, showing significantly higher uptakes in hypoxic than normoxic cells. Immunohistochemical analysis confirmed hypoxia in U87MG and CT-26 xenografted tumor tissues. Moreover, the prepared conjugates were evaluated by in vivo experiments after intravenous injection in U87MG and CT-26 xenografted mice. Hypoxia was confirmed by immunohistochemistry of the prepared derivatives with co-injected pimonidazole. Confocal microscopy of the prepared derivatives showed strong fluorescence in hypoxic tumor tissues correlated with the pimonidazole distribution. This suggested that the 2-nitroimidazole-fluorophore conjugates are promising optical imaging probes for tumor hypoxia and are promising substitutes for pimonidazole immunohistochemistry, which requires a multi-step procedure of incubation involving antibody, second antibody, dye, hydrogen peroxide, and multiple washing steps.

A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study (Kasabach-Merritt 증후군을 동반한 거대 간 혈관종: Tc-99m 적혈구 간 및 전신 혈액풀 신티그래피와 SPECT소견)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae;Kim, Dong-Wook;Yim, Chang-Yeol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.83-86
    • /
    • 2009
  • Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

Miniaturized Chromatographic Quality Control of $^{99m}Tc$ Radiopharmaceuticals (Miniaturized Chromatography에 의한 $^{99m}Tc$-표지 방사성의약품의 정도 관리)

  • Yeom, Mi-Kyoung;Jeong, Jae-Min;Jin, Kwang-Ho;Cho, Kyu-Jin;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.133-137
    • /
    • 1990
  • The general use of a number of $^{99m}Tc-labelled$ compounds makes the need for good routine quality control procedures, especially the labelling efficiency measurements. The purpose of these study were to measure the labelling efficiency of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid using miniaturized paper and instant thin layer chromatography. The chromatographic systems include whatman 3 MM paper and acetone, Gelman ITLC-SG and 0.9% sodium chloride. The chromatographic strips are miniaturized $(1\times10\;cm)$, marked and numbered. Labelling efficiencies of $^{99m}Tc-labelled$ DTPA and Tin colloid were above 98.0%. $^{99m}Tc-labelled$ Antimony sulfide colloid was 90.0%. And labelling efficiency of $^{99m}Tc-labelled$ MDP was 89.0% Coefficient variance of $^{99m}Tc-labelled$ MDP, DTPA, Tin colloid, and Antimony sulfide colloid were 5.14%, 2.06%, 1.82% and 4.90%, respectively. We found that this miniaturized chromatographic quality control was simple and reliable.

  • PDF

Radiopharmaceuticals of Cardiac SPECT Imaging (심장스펙트 영상에 사용되는 방사성의약품)

  • Chung, Yong-An
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • Ever since it was first introduced as a method of scintigraphically measuring regional myocardial perfusion, myocardial perfusion study has been widely used in patients diagnosed or suspected with coronary artery diseases, and continuously improved upon. In addition to the technological enhancement of nuclear medicine equipments, the innovation of radiopharmaceuticals used in the cardiac exams were important contributors to such improvement. Besides the cardiac perfusion studies, new radiopharmaceuticals that visualize fat metabolism or receptors of the sympathetic nervous system have successfully been applied to clinical practice. More information can be collected before diagnosing coronary vascular disease, evaluating the patient's condition, or assessing therapeutic effects. In this review article, the clinical efficacy and characteristics of radiopharmaceutical products tailored for cardiac SPECT that are commonly used in Korea currently, plus the ones not being used yet but have proven value are briefly described.

A Study on the Comparison of One Step Method and Two Step Method to Improve Reporting of CA 19-9 Results (CA 19-9 결과보고 개선을 위한 One step 방식과 Two step 방식의 비교에 관한 연구)

  • Jae-Seok An;Ji-Na Kim;Kwang-Seo Park;Eun-Bit Joo;Sang-Hyuk Yoon;Yoon-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2024
  • Purpose: CA 19-9 is the most widely used tumor marker for the diagnosis of digestive system tumor, especially pancreatic and biliary tract cancer. This study was conducted to improve the result value near reference range by comparing the reagents of CA 19-9 one step method and two step method. In addition, it was intended to establish a standard for selecting reagents. Material and Methods: 120 patients who visited the National Cancer Center in 2023 were selected as subjects for this study. The reagents used in the study were CA 19-9 IRMA kits (Shinjin, Korea) and three types of reagents were compared. Two step method reagent that is currently being used (A), one step method reagent (B) and two step method reagent improved by request (C) were compared and regression analysis was performed on their data. And we also performed recovery test, linearity test and hook effect test for each reagent. Result: There were 46 cases of reagent B in which the concentration value was lower than the result measured in reagent A that was previously used, and 77 cases of reagent C. As a result of regression analysis of reagents A, B, and C, the coefficients of determination of reagents A and B, reagents A and C, and reagents B and C were 0.653, 0.577, and 0.875. In the recovery rate test and the linearity test, the results of all reagents were good, and in the hook effect test, reagent B showed a hook effect at a low value. Conclusion: The improved reagent C appears to have been improved based on the concentration value of reagent B, which the manufacturer judged to be more stable at low concentrations. The hook effect in reagent B can be a fatal reason for disqualification when selecting reagents in general patient samples which high-concentration samples appear frequently. The first improved reagent C will be able to be used once it is confirmed that it has more stability for various concentration values.

A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT (Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Yeo, Jung-Suk;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.172-176
    • /
    • 1994
  • As the Tc-99m-MIBI myocardial SPECT demonstrated wide application in the diagnosis of myocardial function, the quantitative and severity-dependent information is currently re quired. In this study, we proposed a computerized method for scoring the fixed defects in terms of extent-weighted severity and for identifying the reversibility in ischemic regions. At the first stage of this method, the transverse slices were reconstructed with 0.4 Nyquist freq. and order 5 Butterworth filter. From the oblique/sagittal slices, maximal count per pixel circumferential profiles were extracted for each sector, and then stress/redist. polar maps were normalized and plotted. For reversibility, the stress polar map was subtracted from the de-layed image and positive-valued pixels were categorized into three grades. The extent-weight-ed severity scores were calculated using the assigned grades and their number of pixels. This procedure was done automatically and the reversibility and severity scores were produced for each of the coronary territories (LAD, RCA, LCX) or any combination of these. Clinical ap-plication has shown that the changes In reversibility scores after PTCA were correlated linearly with the pre PTCA scores(r>0.8) in postinfarct cases as well as in angina, and severity scores of persistent defects in stress/rest SPECT study matched to the regional ejection fraction and visual analysis of regional wall motion of gated blood pool scan(r>0.6). We conclude that the computerized severity scoring method for the analysis of myocardial SPECT could be useful in the assessment of the myocardial ischemia and fixed defect.

  • PDF

Development of 68Ga-human serum albumin as a PET imaging agent for diagnosis of acute inflammation

  • Lee, Ji Youn;Kim, Hoyoung;Lee, Boeun;Kim, Young Ju;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.104-108
    • /
    • 2015
  • Human serum albumin (HSA) has potential for diagnosis and therapy in clinical setting. The purpose of experiments was to develop and evaluate $^{68}Ga$-HSA as a PET agent for diagnosis of acute inflammation. NOTA-HSA was synthesized by conjugating 2-(p-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid to HSA in 0.1 M sodium carbonate buffer (pH 9.5) and then purified using a PD-10 size-exclusion column. NOTA-HSA was labeled with $^{68}Ga$ at room temperature for 10 min, and 8.4% sodium hydrogen carbonate buffer was added for neutralization. $^{68}Ga$-NOTA-HSA was purified using alumina N plus light cartridge and $0.22{\mu}m$ syringe filter. Labeling efficiency and radiochemical purity were determined by ITLC-SG with 0.1 M citric acid. Biodistribution study was performed in a male BALB/c mice model of Carrageenan-induced acute inflammation. Animal PET study was performed in acute inflammation mice model after tail vein injection of $^{68}Ga$-HSA. This radiotracer showed high labeling efficiency (>99%) around pH 7. Biodistribution study showed higher inflamed footpad uptake than control footpad uptake. Animal PET study revealed 2 times higher uptake on inflamed footpad compared to control footpad. In these experiments, we developed $^{68}Ga$-HSA for acute inflammation PET imaging and evaluated it in a mouse disease model. The results demonstrated that $^{68}Ga$-HSA has potential as a PET imaging agent for diagnosis of acute inflammation.