• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,892, Processing Time 0.03 seconds

Ultrastructural observation of human neutrophils during apoptotic cell death triggered by Entamoeba histolytica

  • Sim, Sco-Bo;Kim, Kyeong-Ah;Yong, Tai-Soon;Park, Soon-Jung;Im, Kyung-Il;Shin, Myeong-Heon
    • Parasites, Hosts and Diseases
    • /
    • v.42 no.4
    • /
    • pp.205-208
    • /
    • 2004
  • Neutrophils are important effector cells against protozoan extracellular parasite Entamoeba histolytica, which causes amoebic colitis and liver abscess in human beings. Apoptotic cell death of neutrophils is an important event in the resolution of inflammation and parasite's survival in vivo. This study was undertaken to investigate the ultrastructural aspects of apoptotic cells during neutrophil death triggered by Entamoeba histolytica. Isolated human neutrophils from the peripheral blood were incubated with or without live trophozoites of E. histolytica and examined by transmission electron microscopy (TEM). Neutrophils incubated with E. histolytica were observed to show apoptotic characteristics, such as compaction of the nuclear chromatin and swelling of the nuclear envelop. In contrast, neutrophils incubated in the absence of the amoeba had many protrusions of irregular cell surfaces and heterogenous nuclear chromatin. Therefore, it is suggested that Entamoeba-induced neutrophil apoptosis contribute to prevent unwanted tissue inflammation and damage in the amoeba-invaded lesions in vivo.

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Relationship between Brain Perfusion SPECT and MMSE Score in Dementia of Alzheimer's Type: A statistical Parametric Mapping Analysis (알쯔하이머형 치매환자에서 SPM 방법을 이용한 뇌 관류 SPECT와 정신-인지기능 수행성능의 상관)

  • Kang, Hye-Jin;Lee, Dong-Soo;Kang, Eun-Joo;Lee, Jae-Sung;Yeo, Seong-Seok;Kim, Jin-Yeong;Lee, Dong-Woo;Cho, Maeng-Je;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.91-101
    • /
    • 2002
  • Purpose : The aim of this study was to identify the brain areas in which reductions of regional cerebral blood flow (rCBF) were correlated with decline of general mental function, measured by Mini-Mental State Examination (MMSE). Materials and Methods : Tc-99m HMPAO brain SPECT was peformed in 9 probable AD patients at the initial and follow-up periods of 1.8 years (average) after the first study. MMSE scores were also measured in both occasions. The mean MMSE score of the initial study 16.4 (range: 5 - 24) and the mean MMSE score of the follow-up was 8.1 (range: 0 - 17). Each SPECT image was normalized to the cerebellar activity and a correlation analysis was peformed between the level of rCBF in AD patients and the MMSE scores by voxel-based analysis using SPM99 software. Results : Significant correlation was found between the blood-flow decrease in left inferior prefrontal region (BA 47) and left middle temporal legion (BA 21) and the MMSE score changes. Additional areas such as anterior and posterior cingulate cortices, precuneus, and bilateral superior and middle prefrontal regions showed the similar trends. Conclusions : A relationship was found between reduction of regional cerebral blood flow in left prefrontal and temporal areas and decline of cognitive function in Alzheimer's disease(AD) patients. This voxel-based analysis is useful in evaluating the progress of cognitive function in Alzheimer's disease.

Parametric Images of Standardized Uptake Values using P-18-FDG Attenuation Corrected Whole Body PET (F-18-FDG감쇠보정 전신 PET을 이용한 표준섭취계수 추정과 매개변수 영상의 구성)

  • Kim, Kyeong-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Yong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.560-569
    • /
    • 1996
  • Background and Purpose : Standardized uptake value(SUV) has been used as a quantitative index for differentiating benign and malignant tumors with F-18-FDG PET In this study, we produced whole body parametric images of SUV(WBPIS) by body weight normalization, and validated the values by comparison with SUV's calculated with regional scans. Subjects and Methods : Whole body scans were followed by regional scans sequentially on 23 patients. In whole body study, transmission and emission scans were acquired for 2 minutes and 6 minutes for each bed position, respectively. In regional study, transmission and emission scans were acquired for 20 minutes. Measured and segmented/ smoothed attenuation correction were applied using these 2 min transmission scans in whole body studies. The effects of attenuation correction on SUVs were evaluated quantitatively using F-18 filled cylindrical phantom. The mean and peak SUVs obtained from WBPIS were compared with SUVs of the regional scans. Results : In phantom studies, with any method of attenuation correction using regional or whole body studies of phantom, SUVs were nearly consistent. In whole body scan, SUV obtained using measured attenuation correction method was a little higher than SUV of regional scan. SUV obtained using segmented/smoothed attenuation correction method was a little lower. In patient studies, WBPIS using segmented/smoothed attenuation correction method was much smoother and more readable. SUVs of WBPIS obtained with both methods of attenuation correction were well correlated with SUVs of regional scans(r=0.9). SUVs of WBPIS with measured attenuation correction method were 5% lower than SUVs of regional scans. SUVs of WBPIS with segmented/smoothed attenuation correction method were 10% lower than SUVs of regional scans. The differences of SUVs of WBPIS by the two attenuation correction methods were relatively small compared with the possible differences derived from biological characteristics of tumors. Conclusion : We concluded that WBPIS could be useful in the quantification of tumor as well as in localization of whole body lesions, which were often outside the field of view in regional scan. WBPIS made using segmented/smoothed attenuation correction method could be used in clinical routines and SUVs from attenuation corrected F-18-FDG PET could be used interchangeably with SUVs of regional studies.

  • PDF

Predictive Factors of Renal Scarring in Children with Acute Urinary Tract Infection (급성 요로감염 환아의 신장 반흔 예측요인)

  • Baik, Jun-Hyun;Park, Young-Ha;Hwang, Sung-Su;Jeon, Jung-Su;Kim, Sung-Hoon;Lee, Seong-Yong;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.245-253
    • /
    • 2003
  • Puorpose: The purpose of this study was to evaluate the usefulness of $^{99m}Tc$ DMSA scintigraphy on the dignosis of a renal scar in children with urinary tract infections. Materials and Methods: Eighty three patients were included in this study, who were diagnosed as the urinary tract infection on the basis of symptom, urinalysis and urine culture. $^{99m}Tc$ DMSA scintigraphy and voiding cystoureterography were peformed within 7days before the treatment in all patients. We classified the scintigraphic findings as follow s : 1 ; a large hypoactive upper or lower pole. 2 ; a small hypoactive area. 3 ; single defect resulting in localized deformity of the outlines. 4 ; deformed outlines in a small or normal sized kidney. 5 ; multiple defects. 6 ; diffuse hypoactive kidney without regional impairment. Follow-up scintigraphy was done at least 6 months after the initial study. When the abnormality on the initial scintigraphy was not completely resolved on the follow-up scan, the lesion was defined as containing a scar. Results: One hundred and fifteen renal units of 166 units(69.3%) showed abnormal findings on the DMSA scintigraphy. 65 units(56.5%) was diagnosed as containing renal scars on follow-up scintigraphies. Incidences of renal scar among renal units showing pattern 3, 4 and 5 on the initial scan was 75%, 78% and 78%, respectively. Whereas many of renal units showing 1, 2 and 6 pattern were recovered(65%, 76%, 50%). Sensitivity, specificity and accuracy of pattern-based DMSA scintigraphic findings on the diagnosis of renal scar was 76.9%, 85.1% and 81.9%, respectively. VUR was significantly associated with the renal scar when the initial DMSA shows unrecoverable findings(pattern 3, 4, 5). Odds ratio of the renal scar in a kidney showing unrecoverable initial scintigraphic findings was 19.1. Odds ratio in a kidney with mild or moderate-to-severe VUR was 3.5 and 14.4 respectively. Conclusion: In the urinary tract infection, renal scar was significantly developed in a kidney showing unrecoverable findings on the initial DMSA scan and VUR on voiding cystoureterography.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor

  • Kim, Tae Hoon;Lee, Sangmin;Kim, Dong Geon;Jeong, Jae Young;Yang, Hye Jeong;Schaarschmidt, Thomas;Choi, Sang Hyoun;Cho, Gyu-Seok;Kim, Yong Kyun;Chung, Hyun-Tai
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3018-3025
    • /
    • 2021
  • The authors developed a volumetric dosimetry detector system using in-house 3D-printable plastic scintillator resins. Three tumor model scintillators (TMSs) were developed using magnetic resonance images of a tumor. The detector system consisted of a TMS, an optical fiber, a photomultiplier tube, and an electrometer. The background signal, including the Cherenkov lights generated in the optical fiber, was subtracted from the output signal. The system showed 2.1% instability when the TMS was reassembled. The system efficiencies in collecting lights for a given absorbed energy were determined by calibration at a secondary standard dosimetry laboratory (kSSDL) or by calibration using Monte Carlo simulations (ksim). The TMSs were irradiated in a Gamma Knife® IconTM (Elekta AB, Stockholm, Sweden) following a treatment plan. The energies absorbed to the TMSs were measured and compared with a calculated value. While the measured energy determined with kSSDL was (5.84 ± 3.56) % lower than the calculated value, the energy with ksim was (2.00 ± 0.76) % higher. Although the TMS detector system worked reasonably well in measuring the absorbed energy to a tumor, further improvements in the calibration procedure and system stability are needed for the system to be accepted as a quality assurance tool.

Evaluating internal exposure due to intake of 131I at a nuclear medicine centre of Dhaka using bioassay methods

  • Sharmin Jahan;Jannatul Ferdous;Md Mahidul Haque Prodhan;Ferdoushi Begum
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2050-2056
    • /
    • 2024
  • Handling of radioisotopes may cause external and internal contamination to occupational workers while using radiation for medical purposes. This research aims to monitor the internal hazard of occupational workers who handle 131I. Two methods are used: in vivo or direct method and in vitro or indirect method. The in vivo or direct method was performed by assessing thyroid intake with a thyroid uptake monitoring machine. The in vitro or indirect method was performed by assessing urine samples with the help of a gamma-ray spectroscopy practice using a High-Purity Germanium (HPGe) Detector. In this study, fifty-nine thyroid counts and fifty-nine urine samples were collected from seven occupational workers who were in charge of 131I at the National Institute of Nuclear Medicine and Allied Sciences (NINMAS), Dhaka. The result showed that the average annual effective dose of seven workforces from thyroid counts were 0.0208 mSv/y, 0.0180 mSv/y, 0.0135 mSv/y, 0.0169 m Sv/y, 0.0072 mSv/y, 0.0181 mSv/y, 0.0164 mSv/y and in urine samples 0.0832 mSv/y, 0.0770 mSv/y, 0.0732 mSv/y, 0.0693 mSv/y, 0.0715 mSv/y, 0.0662 mSv/y, 0.0708 mSv/y.The total annual effective dose (in vivo and in vitro method) was found among seven workers in average 0.1039 mSv/y, 0.0950 mSv/y, 0.0868 mSv/y, 0.0862 mSv/y, 0.0787 mSv/y, 0.0843 mSv/y, 0.0872 mSv/y. Following the rules of the International Commission on Radiological Protection (ICRP), the annual limit of effective dose for occupational exposure is 20 mSv per year and the finding values from this research work are lesser than this safety boundary.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.