A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.

Evaluation of Surgical Outcome with Pre-and Post-operative Rest/Acetazolamide Tc-99m HMPAO SPECT in Children with Moyamoya Disease (어린이 모야모야병에서 휴식/아세타졸아미드 Tc-99m-HMPAO SPECT를 이용한 수술결과 평가)

  • Lee, D.S.;Hyun, I.Y.;Wang, K.C.;Cho, B.K.;Chung, J.K.;Lee, M.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.314-324
    • /
    • 1998
  • Purpose: This study was performed to evaluate the outcome of encephalo-duro-arterio-synangiosis (EDAS) surgery with rest/acetazolamide Tc-99m HMPAO SPECT in moyamoya disease. Materials and Methods: Rost/acetazolamide subtraction SPECT with consecutive acquisition were done before and 2 months after 21 EDAS surgeries in 18 patients. Perfusion decrease was graded visually for 14 areas of each hemisphere as 0 (normal) to 3 (defect) using 4 point scoring system. Postoperative rest perfusion or perfusion reserve was compared with preoperative ones. Results: Among 294 areas of 21 hemispheres, rest perfusion abnormality was found in 91 areas of 15 hemispheres. Decrease of perfusion reserve was found in 146 areas of 18 hemispheres. Six hemispheres having normal rest perfusion and 12 of 15 hemispheres having rest perfusion abnormality showed reserve decrease. Three having rest perfusion defect did not change after acetazolamide in preoperative SPECT. After operation, 16 patients (89%) demonstrated clinical improvement. Fifteen among 18 hemispheres (83%) with decreased reserve improved. Rest perfusion abnormality improved in 6 among the 15 hemispheres (40%). The areas having rest perfusion and/or reserve decrease improved in 87 among 146 areas (60%). Decrease of reserve, improved in 85% (68/80). However, areas without reserve decrease also improved in 29% (19/66). The better was preoperative rest perfusion in involved areas or the more decreased vascular reserve, the more improved perfusion and reserve after operation. Conclusion: We conclude that assessment of perfusion and Perfusion reserve using rest/acetazolamide brain perfusion SPECT predict the surgical outcome in patients with moyamoya disease.

  • PDF

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Study UBC Inspection of the Over Result (UBC 검사의 이상결과에 대한 연구)

  • Park, Jun Mo;Yoo, Hye Jung;Kim, Han Chul;Han, Geul Soon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.101-106
    • /
    • 2013
  • Purpose: As UBC IRMA is being tested, patients out of the reference value are reacting within the value again a few days later the urine collection tested, which causes the reliability of the test to decrease as a result. In this study, we can assume that the physiological changes in the factors would affect the results. The purpose of the study is to find out whether hematuria and proteinuria in the sample as well as the interval time (3 hours or more recommended) have affected the results. As a result, we could discover the changes in factors and increase the reliability of the test. Materials and Methods: 468 people (female: 249, male: 219) who came for the check-up were presented herein for medical examination from 2013.3.15 to 2013.1.2. Some people out of 468 who have reacted onto the reference value were divided into group low titer zone, ow-middle titer zone, and middle-high titer zone and tested for hematuria and proteinuria. During that period, 48 outpatients were asked to fill in a questionnaire regarding the urination interval time. The reagents used were (IDL Biotech AB, Sweden) and UBC IRMA. Results: Of the patients that are formed in the reference value of ($0.1-34.0{\mu}g/L$) turn out to be 52.7 years average age in their low concentration, ($mean{\pm}SD$) of the value of $0.10{\pm}0.02{\mu}g/L$. Among 80 people (50.8%, female: 49.2%), 16 patients (20%) have shown reaction to microscopic hematuria and 10 patients (12.5%) responded to proteinuria. In the average low concentration under 52.5 years of average age, 43 people (53%) have shown reaction to microscopic hematuria and 21 people (26.3%) are proteinuric patients out of 80 patients (male: 50.8%, female: 51.3%). In the middle high concentration of $11.8{\pm}4.82{\mu}g/L$ under the average age 51.7 years, 35 patients (53%) have responded to the microscopic hematuria and proteinuric patients are 26 people (39.3%) out of 66 people (men: 44%, women: 56%). In addition, in the concentration of $51.7{\pm}43.5{\mu}g/L$, some patients who get out of the reference value are observed as the average age of 52.0. 11 patients (78.6%) out of 14 (male: 35.7%, female: 64.3%) react to the microscopic hematuria. There show 6 people (42.8%) who turn out to be as proteinuric patients. As for the interval time, $1.67{\pm}3.71{\mu}g/L$ was the average value among 48 patients (female: 45.8%, male: 54.2%). Conclusion: We cannot see if proteinuria and hematuria directly affect abnormal results of inspection of 8,18 cytokeratin; however, we can find out that they statistically have an influence on highly generating UBC among several mechanisms. Also, although urination interval time was various every 15 minutes, we it does not affect these results.

  • PDF

A Study on How Height and Weight Affects Glomerular Filtration Rate (신장과 체중의 변화가 사구체 여과율에 미치는 영향)

  • Park, A Rang;Choi, Jong Sook;Lee, Young Hee;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Purpose Glomerular filtration rate (GFR) is an important index for evaluation of renal function, renal disease diagnosis and progress monitoring. Therefore, accurate measurement of GFR is clinically important. Among the factors that affect the GFR result, there have been many discussions on the methods such as the correction of the kidney depth, net syringe count, and the method of setting the ROI. However there has been no consideration of counting in the most basic factors like height and weight measurement. In this study, we investigate how height and weight changes affects the result of GFR and review the importance of standardized body measurements. Materials and Methods Fifty patients who underwent GFR test were randomly sampled and examined for changes in height and body weight within one month. From the normal patients without renal disease to the patients with severely decreased GFR, we applied the GFR formula of Gate with varying height and weight. Results: The result showed variation of the height at maximum three centimeters and six kilograms of weight. The first calculation of GFR was done with fixed height value and control variable as weight. Weight was incremented by one kilogram each time up to six kilograms. The GFR showed increased result with increasing weight. The result of GFR showed ten percent increase with six kilograms of weight increase. On the other hand, when height value was incremented by one centimeter up to three centimeters showed decreased GFR result with fixed weight value. Up to three centimeters of height increase showed two percent of decreased GFR with fixed weight. Conclusion This study showed varying GFR result when height and weight changes. Therefore it is clinically crucial not only to maintain and manage body measuring instrument but also to have a standardized measurement methods to derive accurate measured values and to achieve reproducibility.

A Comparative Pharmacokinetic and Biodistributional Study of $^{131}I$ OIH and $^{99m}Tc-MAG_3$ ($^{131}I$ OIH와 $^{99m}Tc-MAG_3$의 약물동력학 및 체내 분포에 관한 비교 연구)

  • Jeong, Jae-Min;Yeom, Mi-Kyoung;Kim, Mun-Hye;Park, Kyung-Ho;Song, Sae-Heum;Lee, Bum-Woo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.74-79
    • /
    • 1990
  • $^{99m}Tc-MAG_3$ was synthesized, and biodistribution and blood clearance rate were compared with those of $^{131}I-OIH$ in mice and rats respectively. Finally renal image was obtained from a normal male volunteer before and after prescription of probenecid. The results obtained were as follows: 1) The uptake of $^{99m}Tc-MAG_3$ by kindey was higher than that of $^{131}I-OIH$ in mice 10 mins after injection (n=6, p<0.05), but slightly lower uptakes were found in all organs (kindney, blood, stomach, intestinge and liver) 2 hrs after injection. 2) For $^{99m}Tc-MAG_3$ $4\frac{1}{2}\;\alpha=2.4{\pm}0.0\;min,\;t\frac{1}{2}\;\beta=44.3{\pm}7.4\;min$, and blood clearance=$3.4{\pm}0.5ml/min$, and for $^{131}I-OIH\;t\frac{1}{2}\;\alpha=1.8{\pm}0.2\;min,\;\beta=69.1{\pm}9.5\;min$, and blood clearance=$1.3{\pm}0.1\;min$ were found in rats. 3) From the renogram of normal male volunteer, we could find that tmax=130 sec and $t\frac{1}{2}=430\;sec$ before probenecid prescription, and $tmax=150\sim170$ sec and $t\frac{1}{2}=810\sim1,170$ sec after probenecid prescriprion. From these results we concluded that $^{99m}Tc-MAG_3$ can be used instead of $^{131}I-OIH$ for obtaining renal image.

  • PDF

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

A Study on Optimal Myocardium Perfusion SPECT According to Possible Myocardial Infarct Sites (8) 예측성 경색 부위별 최적의 심근관류 단층촬영술 시행에 관한 연구)

  • Song Jae Beom;Lee Wan Kyu;Shu Myung Duk;Jang Sang Sup
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.234-252
    • /
    • 1999
  • Purpose : Physical properties of radiophamaceuticals of technetium($^{99m}Tc$) and thallium($^{201}Tl$) have early been used for clinical diagnostics. The studies of those radiophamaceuticals have been contributed to the efficient to

  • PDF

Standardization of Thyroidal Radioiodine ($^{131}I$) Uptake Study in Korea (한국(韓國)에서의 방사성옥소(放射性沃素)($^{131}I$)의 갑상선(甲狀腺) 섭취율(攝取率) 검사(檢査)의 표준화(標準化)에 관(關)한 연구(硏究))

  • 대한핵의학회 학술부
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.1
    • /
    • pp.71-76
    • /
    • 1971
  • 7 laboratories located in Seoul were surveyed for the standardization of radioiodine thyroid uptake test in Korea. The result revealed that the currently utilized methods are almost standardized now, when the reference standard is IAEA recommendation method, 1962. Mean 24 hour uptake of thyroidal $^{131}I$ in Korean euthyroids is $31.6{\pm}8.80%$, and no significant interlaboratory differences are noticed. These results were caused probably by the late introduction of detector facilities into Korea after the appearance of publication of IAEA recommendations.

  • PDF

Scintillation Proximity Assay (섬광근접측정법)

  • Choi, Chang-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.461-465
    • /
    • 1999
  • Scintillation proximity assay (SPA) is a unique type of radioimmunoassay and makes it possible to use radioisotopes for monitoring binding reactions continuously without separation procedure. Microbeads containing a fluorophor are covalently linked to antibody or receptor. When a radiolabeled antigen or ligand is added it binds to the beads and the emitted short range electrons, excite the fluorophor in the beads. The light emitted can be measured in a scintillation counter. $^3H$ or $^{125}I$ has been used for SPA. The sensitivities achieved with SPA are comparable to the sensitivities of other procedures. SPA is applicable to immunology, receptor binding, monitoring interactions of biomolecules and study for the kinetics of interaction between receptors and ligands.