• Title/Summary/Keyword: Nuclear medicine study

Search Result 2,876, Processing Time 0.03 seconds

Effects of Attenuation and Scatter Corrections in Cat Brain PET Images Using microPET R4 Scanner (MicroPET R4 스캐너에서 획득한 고양이 뇌 PET 영상의 감쇠 및 산란보정 효과)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Jong-Jin;Lee, Byeong-Il;Park, Min-Hyun;Lee, Hyo-Jeong;Oh, Seung-Ha;Kim, Kyeong-Min;Cheon, Gi-Jeong;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.40-47
    • /
    • 2006
  • Purpose: The aim of this study was to examine the effects of attenuation correction (AC) and scatter correction (SC) on the quantification of PET count rates. Materials and Methods: To assess the effects of AC and SC $^{18}F$-FDG PET images of phantom and cat brain were acquired using microPET R4 scanner. Thirty-minute transmission images using $^{68}Ge$ source and emission images after injection of FDG were acquired. PET images were reconstructed using 2D OSEM. AC and SC were applied. Regional count rates were measured using ROIs drawn on cerebral cortex including frontal, parietal, and latral temporal lobes and deep gray matter including head of caudate nucleus, putamen and thalamus for pre- and post-AC and SC images. The count rates were then normalized with the injected dose per body weight. To assess the effects of AC, count ratio of "deep gray matter/cerebral cortex" was calculated. To assess the effects of SC, ROIs were also drawn on the gray matter (GM) and white matter (WM), and contrast between them ((GM-WM)/GM was measured. Results: After the AC, count ratio of "deep gray matter/cerebral cortex" was increased by $17{\pm}7%$. After the SC, contrast was also increased by $12{\pm}3%$. Conclusion: Relative count of deep gray matter and contrast between gray and white matters were increased after AC and SC, suggesting that the AC would be critical for the quantitative analysis of cat brain PET data.

An Experimental Study on the Change of Bone Mineral Metabolism After Irradiation (방사선 조사후 골무기질 함량의 변화에 관한 실험적 연구)

  • Hong, Sung-Woon;Lim, Sang-Moo;Jang, Ja-June;Lee, Jhin-Oh;Kang, Tae-Woong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.307-316
    • /
    • 1990
  • Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of Cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absorptiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before the presentation of the osteoradionecrosis can be diagnosed early with the dual photon absorptionmetry and bone scintigraphy.

  • PDF

Diagnostic Criteria to Differentiate Medial Meniscal Injury from Degenerative Changes on $^{99m}Tc-MDP$ Knee SPECT in Patients with Chronic Knee Pain (만성 무릎관절 통증환자에서 내측 반월상연골 손상과 관절 퇴행성 변화의 감별을 위한 $^{99m}Tc-MDP$ 무릎관절 SPECT의 진단기준)

  • Paeng, Jin-Chul;Chung, June-Key;Jeong, Hwan-Jeong;Yoo, Jae-Ho;Kang, Won-Jun;So, Young;Lee, Dong-Soo;Lee, Myung-Chul;Seong, Sang-Cheol;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.103-109
    • /
    • 2003
  • Purpose: In patients with chronic knee pain, the diagnostic performance of $^{99m}Tc-MDP$ knee SPECT for internal derangement of knee is deteriorated due to degenerative changes. In this study, we tried to establish diagnostic criteria to differentiate medial meniscal injury (MMI) from degenerative change (DC) when the uptake is increased in medial compartment. Materials and Methods: A total of 49 knee SPECT of the patients with chronic (more than 3 months) knee pain, which showed increased $^{99m}Tc-MDP$ uptake in the medial compartment, were included in this study. The diagnosis was confirmed by arthroscopy. On knee SPECT, 3 diagnosic criteria for MMI were investigated. In Criterion I, MMI was diagnosed when crescentic uptake was observed in the medial tibial plateau. In Criterion II, crescentic uptake was further classified into anterior, mid, posterior, and diffuse patterns, according to the location of maximal uptake; and only crescentic mid, posterior, and diffuse patterns were diagnosed as MMI. In Criterion III, MMI was diagnosed when medial tibial plateau showed higher activity then medial femoral condyle. The diagnostic performance of the 3 criteria was compared. Results: The sensitivity and specificity were 93% and 14% in Criterion I, 89% and 38% in Criterion II, and 75% and 67% in Criterion III, respectively. Criterion III had significantly improved diagnostic performance, especially, specificity. Conclusion: In this study, we established a practical diagnostic criterion to differentiate MMI from DC on knee SPECT. The result is helpful to improve the diagnostic value of knee SPECT as a screening test for chronic knee pain.

Radionuclide (Tc-99m) Hysterosalpingography for Evaluation of Fallopian Tube Patency (동위원소(Tc-99m HAM)를 이용한 난관 조영술)

  • Park, Won;Kim, Chong-Soon;Park, Chang-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.207-211
    • /
    • 1987
  • A prospecitive study was performed to evaluate the efficacy of Radionuclide Hysterosalpingography (RNHSG), that was modified by McCalley, et al. for the evaluation of fallopian tube. Using spontaneous migration of Tc99m labelled human albumin microsphers (HAM) and images got with Gamma camera, the study was made in 20 gynecological patients (44 tubes) in an effort to confirm the anatomical patency or obstruction as well as functional one at the Department of Obstetrics and Gynecology, National Medical Center from January 1, 1986 to July 31, 1986. The efficacy was also compared with that of contrast hysterosalpingography and surgical observation. Results obtained were as follows; 1) The Radionuclide Hysterosalpingography appeared to be a simple and accurate procedure as a mean with which anatomical tubal patency, as well as functional patency can be detected, although it's some limit in showing anatomical details of uterine cavity and tubes in comparison with contrast hysterosalpingography. 2) The predicted value of tubal obstruction was 82.4%. and that of tubal patency was 88.9% respectively. Overall efficacy (percent of tube correctly classified) of Radionuclide Hysterosalpingography was 88.6%. 3) There was no nuclide related complication during and after the procedure.

  • PDF

Therapeutic Feasibility Study and Clinical Trial of Intrahepatic $I^{-131}-Lipiodol$ on Patients with Hepatocellular Carcinoma ($Lipiodol-I^{-131}$의 경간동맥 주입에 의한 간암치료의 가능성에 관한 연구)

  • Yoo, Hyung-Sik;Suh, Jung-Ho;Lee, Jong-Tae;Kim, Dong-Ik;Park, Chang-Yun;Kim, Byung-Soo;Park, Chan-H.;Thakur, M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.61-71
    • /
    • 1986
  • An iodized oil such as Ethiodol or Lipiodol was selectively retained in the tumor vessels of the large hepatomas as well as in the small daughter hepatomas for long periods following the intra-arterial hepatic injection of such contrast material. The specific aim of the study is to deliver a high internal radiation dose to hepatocellular carcinoma (HCC) in an attempt to control the disease. We were able to replace a small fraction of the stable iodine (I-127) of the 37% iodine in Lipiodol by the $I^{-131}$ with 100% exchange efficiency. $I^{-131}$ labeled Lipiodol was injected through the super-selected tumor feeding artery under superselection or into the proper hepatic arterial level of patients who have malignant hepatomas confirmed by aspiration cytology serum AFP and various imaging modalities. Clinical traial was performed on 43 cases during recent 6 months and follow-up observation was carried out. No severe complications or other adverse reactions were encountered until nowdays. $I^{-131}-Lipiodol$ was stable in vivo and no significant activity was noted in the thyroid, stomach, blood and urine after the injection. Only small fraction of radioisotope activity was noticed in the both side of lungs. Tumor to normal liver radio was very high. Therefore, $I^{-131}-Lipiodol$ (or P-32-Lipiodol) will be effective delivering high internal radiation dose to the tumor while delivering small radiation doses to normal tissues. Labeling, tumor dose calculation and preliminary findings will be presented.

  • PDF

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

First Report on External Quality Assurance Study of Radioassay of Thyroid Related Hormones - First One Year of Operation From 1989. 9 To 1990. 8- (갑상선 호르몬의 외부정도 관리 분석 -1989년 9월부터 1990년 8월까지 첫해 시행 결과-)

  • Lee, Dong-Soo;Cho, Bo-Youn;Kwark, Cheol-Eun;Seo, Il-Taek;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.266-279
    • /
    • 1991
  • 1989년 9월부터 1990년 8월까지 국제 원자력기구의 지역 계획에 의해 국내 26개 (후반부 31개)의 기관이 참가하여 T3, T4, TSH를 측정하여 결과를 모으고, 외부정도관적를 시행한 결과가 다음과 같다. 1) 외부정도관리를 위한 컴퓨터 소프트웨어를 작성하였다. 데이타의 입력, 정도 분석, 월별 보고, 분기별 보고 및 수행 분석 프로그램을 만들되 전체 검사실결과에서 추린 평균값(all laboratories trimmed mean: ALTM)으로 모집단평균을 삼아 편차, 편이, 편이평균 그리고 이들의 경시적 변화를 분석하도록 하였다. 2) 전후반 2회에 나누어 만든 및치 사이의 편차는 유의하지 않았다. T3값의 변이계수는 7.2%이하(정상 T3 값) 또는 9.2%와 13.4%사이 (높은 T3 값), 74 값의 변이계수는 4.6%이하(정상 또는 높은 T4값), 5.4%와 9.5%사이(낮은 T4값)이었다. TSH는 정상범위 값에서 21.7%이하의 변이 계수를 보였고 정상보다 낮거나 높은 TSH의 풀은 8 7%와 21.2%사이의 변이제수를 보였다. 3) 전체 검사실 추린 평균값(ALTM)에 따른 변이계수의 변동은, ALTM이 정상 T4값범위일 때 변이계수는 15%이하이었고, 낮은 T4값일 때는 중간값이 15%이고 분포범위는 50%까지이었다. T3값의 변이계수는 대체로 20%이하이었다. TSH의 변이계수는 1mU/L를 전후로 급격히 상승하여 200%에 달하였다. 4) 3표준편차보다 높거나 낮은 값을 보인 검사실들의 분포는 전체 검사실결과에서 추린 평균값(ALTM)과 상관없었다. 5) 첨가한 T3, T4, TSH에 대한 회수율은 T4는 104, 106%, T3는 67%, 74%, TSH는 87%, 86%이었다. 이상과 같이, 저자들이 만든 소프트웨어 프로그램으로 외부정도관리를 위하여 쉽게 데이터를 분석하고 보고서를 작성하여 갑상선호르몬의 경사신뢰도를 평가할 수 있게 되었으며, 위에 요약한 첫 해의 외부정도관리 결과를 바탕으로 참가기관의 동의하에, 앞으로 정도관리 항목의 확대와 외부정도관리의 지속적인 시행이 바람직하다고 생각하였다.

  • PDF

Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy (Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가)

  • Seo, Young-Deok;Jeong, Jae-Hun;Moon, Jong-Woon;Yun, Sang-Hyeok;Kim, Yeong-Seok;Kang, Se-Hun;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

The Study of RIA Development Direction using Suggestion System (제안제도를 활용한 RIA 발전 방향에 관한 연구)

  • Shin, Young-Kyun;Chun, Jun-Hong;Kim, Yeon-Ok;Lee, Seon-Ho;Kim, Seong-Ho;Yoo, Seon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.106-112
    • /
    • 2011
  • Purpose: Until now, the process was improved by the needs of experimenters personally. But recently, suggestion system in hospital has been activated in various ways. So the department of nuclear medicine laboratory is also aware of the need of operation improvement using suggestion system. It is intend to assist in the development by sharing excellent suggestion cases with other hospitals. Material & Method: A total of 124 suggestion cases from January 2007 to March 2010 were analyzed. Suggestion cases were divided into customer satisfaction, cost reduction, improved testing methods, equipment, environmental improvement, and computational system. Result: Suggestion cases of environmental improvement and computational system were accounted for 26.6% as 33 cases, respectively. Suggestion for customer satisfaction is 25.8% as 32 in a total of 124 cases. Conclusion: Activation of the awareness of operation improvement is induced by suggestion system. By securing system of operation improvement, employees' ideas can lead to the production and systematization. Furthermore, it enhances hospital competitiveness and promotes the development of the hospital.

  • PDF

Biological Dosimetry of In Vitro Irradiation with Radionuclides : Comparison of Whole Blood, Lymphocyte and Buffy Coat Culture (전혈, 림프구와 백혈구 연층 각각의 방사성 동위원소 체외 조사 후 배양을 이용한 생물학적 선량측정)

  • Kim, Jong-Ho;Lee, Dong-Soo;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kim, Chong-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.125-132
    • /
    • 1995
  • The purpose of this study was to establish mononuclear cell cultures such as lymphocytes or buffy coat for the biological dosimetry of in vitro Irradiation of the radionuclide Tc-99m in order to exclude the effect of residual doses seen in the cultures of whole blood. Biological do simetry of Tc-99m on cultured mononuclear cells at doses ranging from 0.05 to 6.00 Gy, by scoring unstable chromosomal aberrations(Ydr) observed in cultured lymphocytes, were performed using peripheral venous blood of healthy normal person. The results showed that; (1) In vitro irradiation of radioisotope in separated lymphocyte or buffy coat showed trace amount of residual doses of isotope after washing. Residual doses of isotopes are increased in proportion to exposed time and irradiated dose without difference between I-131 and Tc-99m. (2) We obtained these linear-quadratic dose response equations in lymphocyte and buffy coat culture after in vitro irradiation of Tc-99m, respectively (Ydr = 0.001949 $D^2$ +0.006279D + 0.000185; Ydr= 0.002531 $D^2$-0.003274 D+0.003488). In conclusion, the linear quadratic dose-response equation from in vitro irradiation of Tc-99m with lymphocyte and buffy coat culture was thought to be useful for assessing Tc-99m induced biological effects. And mono-nuclear cell cultures seem to be the most appropriate experimental model for the assessment of biological dosimetry of internal irradiation of radionuclides.

  • PDF