• Title/Summary/Keyword: Nu-A

Search Result 818, Processing Time 0.028 seconds

W Chemical Mechanical Polishing (CMP) Characteristics by oxidizer addition (산화제 첨가에 따른 W-CMP 특성)

  • Park, Chang-Jun;Seo, Yong-Jin;Lee, Kyoung-Jin;Jeong, So-Young;Kim, Chul-Bok;Kim, Sang-Yong;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.46-49
    • /
    • 2003
  • Chemical mechanical polishing (CMP) is an essential dielectric planarization in multilayer microelectronic device fabrication. In the CMP process it is necessary to minimize the extent of surface defect formation while maintaining good planarity and optimal material removal rates. The polishing mechanism of W-CMP process has been reported as the repeated process of passive layer formation by oxidizer and abrasion action by slurry abrasives. Thus, it is important to understand the effect of oxidizer on W passivation layer, in order to obtain higher removal rate (RR) and very low non-uniformity (NU%) during W-CMP process. In this paper, we compared the effects of oxidizer or W-CMP process with three different kind of oxidizers with 5% hydrogen peroxide such as $Fe(NO_3)_3$, $H_2O_2$, and $KIO_3$. The difference in removal rate and roughness of W in stable and unstable slurries are believed to caused by modification in the mechanical behavior of $Al_3O_3$ particles in presence of surfactant stabilizing the slurry.

  • PDF

Anticachexic Effects of Kwibi-tang on Non-small Cell Lung Carcinoma, NCI-H520 Xenograft Mice (귀비탕(歸脾湯)이 비소세포 폐암세포(NCI-H520) 이식 마우스에서 악액질 억제에 미치는 영향)

  • Son, Ji-young;Kim, Kyung-soon;Choi, Hae-Yun;Kim, Jong-Dae
    • Journal of Korean Traditional Oncology
    • /
    • v.20 no.2
    • /
    • pp.23-36
    • /
    • 2015
  • Purpose : The object of this study was to observe anti-cachexic effects of Kwibi-tang extracts (KBTe) on non-small cell lung carcinoma (squamous epithelial carcinoma), NCI-H520, xenograft Balb/c nu-nu nude mice. Methods : Three different dosages of KBTe, 50, 100 and 200 mg/kg were orally administered once a day for 42 days from 11 days after tumor cell inoculation. Six groups, each of 8 mice per group were used in the present study. Changes on the body weight, the epididymal fat weight and serum IL-6 levels were detected with the thicknesses of deposited cervical brown adipose tissue and their mean diameters to monitor the tumor-related anticachexic effects. Results : Deceases on the body weight and gains were also demonstrated in tumor-bearing control with increases of serum IL-6 levels, decreases of epididymal fat pad weight, atrophic changes of cervical brown adipose tissues. These are means that tumor-related cachexia are induced by tumor cell inoculations in the present study. However, these tumor-related cachexia were markedly inhibited by all three different dosages of KBTe treatment as compared with tumor-bearing control. 5-FU showed somewhat deteriorated the tumor-related cachexia in the present study. Conclusion : The results obtained in this study suggest that over 50 mg/kg of KBTe showed favorable anticachexic effects on the NCI-H520 cell xenograft. However, detail mechanism studies should be conducted in future with the screening of the biological active compounds in this herb.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Evaluating the prediction models of leaf wetness duration for citrus orchards in Jeju, South Korea (제주 감귤 과수원에서의 이슬지속시간 예측 모델 평가)

  • Park, Jun Sang;Seo, Yun Am;Kim, Kyu Rang;Ha, Jong-Chul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.3
    • /
    • pp.262-276
    • /
    • 2018
  • Models to predict Leaf Wetness Duration (LWD) were evaluated using the observed meteorological and dew data at the 11 citrus orchards in Jeju, South Korea from 2016 to 2017. The sensitivity and the prediction accuracy were evaluated with four models (i.e., Number of Hours of Relative Humidity (NHRH), Classification And Regression Tree/Stepwise Linear Discriminant (CART/SLD), Penman-Monteith (PM), Deep-learning Neural Network (DNN)). The sensitivity of models was evaluated with rainfall and seasonal changes. When the data in rainy days were excluded from the whole data set, the LWD models had smaller average error (Root Mean Square Error (RMSE) about 1.5hours). The seasonal error of the DNN model had the similar magnitude (RMSE about 3 hours) among all seasons excluding winter. The other models had the greatest error in summer (RMSE about 9.6 hours) and the lowest error in winter (RMSE about 3.3 hours). These models were also evaluated by the statistical error analysis method and the regression analysis method of mean squared deviation. The DNN model had the best performance by statistical error whereas the CART/SLD model had the worst prediction accuracy. The Mean Square Deviation (MSD) is a method of analyzing the linearity of a model with three components: squared bias (SB), nonunity slope (NU), and lack of correlation (LC). Better model performance was determined by lower SB and LC and higher NU. The results of MSD analysis indicated that the DNN model would provide the best performance and followed by the PM, the NHRH and the CART/SLD in order. This result suggested that the machine learning model would be useful to improve the accuracy of agricultural information using meteorological data.

Natural Cconvection in a Vertical Channel with Thermal Blocks (장방형 발열체가 부착된 채널에서 자연대류 연구)

  • 최용문;박경암
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.438-444
    • /
    • 1993
  • The circuit board of an electronic equipment were simulated with a vertical channel which had thermal blocks protruded from one of the channel walls. A rought front plate was made of a circuit board attached with short wires to simulate the back side of a printed circuit board. Natural convection experiments were carried out to study the effects of channel space and rough front plate and to find the suitable characteristic value after the fourth row. The effect of a rough front plate was negligble. There were negligible effects of the channel space on the first and second heaters. Heat transfer coefficients after the third row decreased as the channel space decreased. Heat transfer coefficients were almost constant for larger than 20 mm channel space. A characteristic length was suggested to non-dimensionalize Nu and Ra numbers in a vertical channel with protruded heaters. A correlation was obtained using the new characteristic lengths.

An Experimental Study on Swirling Flow in a Sudden Expansion Tube using 3D PIV Technique (3D PIV 기법을 이용한 선회유동의 급팽창에 관한 실험적 연구)

  • Chang, Tae-Hyun;Kil, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.272-281
    • /
    • 2009
  • The effect of swirl on the flow characteristics in a sudden expansion tube was examined experimentally by using 3D PIV(particle image velocimetry) to capture the velocity profiles. The swirling flow of water through a sudden 1:2 axisymmetric expansion has previously been studied experimentally within a horizontal round tube. A kind of tangential slot is used as a swirl generator for swirling flow and a honey comb is used for without swirl flow. The work with the swirl and without swirl results are compared to each other at the same Reynolds number. Liquid crystal was employed to measure temperature profiles and heating coil used for heat transfer with and without swirl flow. And then the Nusselt number ratoes(Nu/Nudb) are calculated along the test section.

DIFFERENCE CORDIALITY OF SOME SNAKE GRAPHS

  • Ponraj, R.;Narayanan, S. Sathish
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.3_4
    • /
    • pp.377-387
    • /
    • 2014
  • Let G be a (p, q) graph. Let f be a map from V (G) to {1, 2, ${\ldots}$, p}. For each edge uv, assign the label ${\mid}f(u)-f(\nu){\mid}$. f is called a difference cordial labeling if f is a one to one map and ${\mid}e_f(0)-e_f(1){\mid}{\leq}1$ where $e_f(1)$ and $e_f(0)$ denote the number of edges labeled with 1 and not labeled with 1 respectively. A graph with admits a difference cordial labeling is called a difference cordial graph. In this paper, we investigate the difference cordial labeling behavior of triangular snake, Quadrilateral snake, double triangular snake, double quadrilateral snake and alternate snakes.

A Study on the Heat Transfer of a Liquid Droplet on Heated Surface at the Transitional Boiling Region (가열면상 의 단일액적 의 천이비등영역 에서의 열전달 에 대한 연구)

  • 최인규;남궁규완;이동진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.18-25
    • /
    • 1984
  • The transition boiling of a liquid droplet on a heated flat surface was studied utilizing Kotake's model with the effects of viscosity of a thin vapor layer between the droplet and the hot plate taken into account. This problem was analyzed considering the process of the droplet evaporation which resulted in hydrodynamic instability at the liquid-vapor interface. The results of the study are as follows; (1)The effect of the viscosity in the vapor layer at the interface appears as a dimensionless number N, namely .sigma. .delta.$_{0}$ /.rho.nu.$^{2}$ (2)The time required for evaporation at the transitional region increases with the temperature difference ratio .DELTA. T$_{r}$. The rate of increase of the total evaporation time becomes larger as increasing of N$_{m}$(N number at maximum heat flux) increases.s.

Local heat transfer measurement inside microchannel (마이크로채널에서의 국소 열전달 측정)

  • Cho, Dae-Gwan;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1902-1907
    • /
    • 2008
  • The current work presents a design and fabrication technique for a microchannel system to measure the local temperature distribution inside microchannel. This micro channel system fabricated by MEMS technique is integrated with a heater and an array of temperature sensors so that detailed heat transfer phenomena inside micro-scale channel can be studied. Materials widely used in semiconductor process were selected to fabricate a heater and temperature sensors on a silicon wafer. On these heater and sensors a channel wall was fabricated with SU-8. The friction constant and the local Nusselt number distribution measured for the deionized water flow in the microchannel is presented.

  • PDF

Successful ankle replantation in two cases with different presentations

  • Wen, Adzim Poh Yuen;Jusoh, Mohd Hanifah;Saad, Arman Zaharil Mat;Halim, Ahmad Sukari;Faisham, Nu'man Wan Ismail Wan;Azman, Wan Sulaiman Wan
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.182-186
    • /
    • 2020
  • We report our experience of treating two patients with ankle amputation with different presentations. The first case was a clean-cut sharp amputation. The second case was an avulsion injury following a motor vehicle accident in a patient who arrived 8 hours after the injury. Replantation was successful in both cases. In avulsion injuries, a secondary operation for wound coverage is required at a later stage. With good strategy and a support team, encouraging limb survival outcomes are possible post-replantation.