• Title/Summary/Keyword: Novel Phase State

Search Result 173, Processing Time 0.031 seconds

A Novel Three-Phase Quasi-Resonant DC Link Inverter (새로운 3상 준공진 직류링크 인버터)

  • Lee, Jin-Woo;Park, Min-Ho;Won, Jong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.5
    • /
    • pp.479-488
    • /
    • 1991
  • A novel three-phase quasi-resonant dc link inverter (QRI)with a switch connected between dc voltage source and resonant inductor is proposed. According to the state of switching and load current, the operating mode of the proposed inverter scheme is classified into free-wheeling, inverting, and rectifying mode. By examining the behavior of the circuit in each operating mode, an equivalent circuit which represents all the modes in a unified manner is derived. The operating principle of QRI at inverting mode is analyzed, and it is shown that the maximum voltage of resonant dc link is confined to twice the dc source voltage and that both the zero voltage switching of inverter and the zero current switching of inserted switch are guaranteed. An appropriate current control algorithm is suggested, and the opeating characteristics of proposed resonant inverter are verified through both simulation and experiment.

  • PDF

PMMA Coated BaF2:Er3+ Nanoparticles via a Novel One-Step Reverse-Emulsion Polymerization Process

  • Lian, Hongzhou;Fu, Lianshe;Andre, Paulo S.;Lin, Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2451-2454
    • /
    • 2013
  • Poly(methyl methacrylate) coated $BaF_2:Er^{3+}$ nanoparticles were prepared via a novel reverse-emulsion polymerization process using methyl methacrylate as continuous phase and water as dispersed phase. Preparation and coating of $BaF_2:Er^{3+}$ particles were processed in a single step. The resulting polymeric composites show the characteristic $Er^{3+}$ luminescence at excitation of 980 nm and may have potential applications in amplified optical networks.

A Novel Single Phase Soft Switched PFC Converter

  • Altintas, Nihan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1592-1601
    • /
    • 2014
  • In this study, a novel single phase soft switched power factor correction (PFC) converter is developed with active snubber cell. The active snubber cell provides boost switch both to turn on with zero voltage transition (ZVT) and to turn off with zero current transition (ZCT). As the switching losses in the proposed converter are too low, L and C size can be reduced by increasing the operating frequency. Also, all the semiconductor devices operate with soft switching. There is no additional voltage stress in the boost switch and diode. The proposed converter has a simple structure, low cost and ease of control as well. It has a simple control loop to achieve near unity power factor with the aid of the UC3854. In this study, detailed steady state analysis of the proposed converter is presented and this theoretical analysis is verified by a prototype of 100 kHz and 500 W converter. The measured power factor and efficiency are 0.99 and 97.9% at full load.

Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter (듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기)

  • Lee, Sang-Wook;Ryu, Yeoi-Joung;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

Robust Controller Design with Novel Sliding Mode Surface-Linear Optimal Control Case (새로운 스위칭 평면을 이용한 강인한 최적 제어기의 설계)

  • Park, Seung-Kyu;Ahn, Ho-Kyun;Kim, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.446-448
    • /
    • 1998
  • In this paper, a novel sliding surface is proposed by introducing a virtual state. This sliding surface has nominal dynamics of an original system and makes it possible that the Sliding Mode Control(SMC) technique is used with the various types of controllers. Its design is based on the augmented system whose dynamics have one higher order than that of the original system. The reaching phase is removed by using an initial virtual state which makes the initial switching function equal to zero.

  • PDF

A Study on the novel voltage converter for PWM control method (PWM 제어방식에 의한 새로운 전압형 컨버어터에 관한 연구)

  • Chung, Y.T.;Seo, Y.S.;Han, K.H.;Lee, S.Y.;Kim, H.W.;Lee, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.999-1001
    • /
    • 1992
  • This paper describes the voltage type PWM converter. Input AC current is to be sinusoidal and AC input voltage is determined by controlling the phase of the source and converter properly. By corresponding the phase of input voltage to that of base current, DC constant voltage Is to be output with high power factor driving. Also it is possible to be leading or lagging power factor driving. Optimum driving is performed by controlling the current instantaneously in the steady state or transient state.

  • PDF

A New Family of Cascaded Transformer Six Switches Sub-Multilevel Inverter with Several Advantages

  • Banaei, M.R.;Salary, E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1078-1085
    • /
    • 2013
  • This paper presents a novel topology for cascaded transformer sub-multilevel converter. Eachsub-multilevel converter consists of two DC voltage sources with six switches to achieve five-level voltage. The proposed topology results in reduction of DC voltage sources and switches number. Single phase low frequency transformers are used in proposed topology and voltage transformation and galvanic isolation between load and sources are given by transformers. This topology can operate as symmetric or asymmetric converter but in this paper we have focused on symmetric state. The operation and performance of the suggested multilevel converter has been verified by the simulation results of a single-phase nine-level multilevel converter using MATLAB/SIMULINK.

Improvement on transient response of a Indirect Controlled Current PWM - VSC (간접전류제어 PWM 전압형 CONVERTER의 과도응답 개선)

  • Park, Min-Ho;Lee, Jin-Woo;Park, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.245-249
    • /
    • 1989
  • From the careful analysis of the transformed dq system equations of a PWM Voltage Source Converter ( PWM - VSC ), a novel voltage control is proposed which is based on the derivative of in-phase current component of line currents and the relation between dc-link voltage and in-phase current component. A simple logical algorithm to implement the proposed scheme is also presented at transient state. The sinusoidal PWM is adopted at steady state. The simulation results show good transient characteristics.

  • PDF

Modeling and Control of Three-Phase Self-Excited Induction Generator Connected to Grid

  • Chandrasekaran, Natarajan;Karthikeyan, A
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.265-272
    • /
    • 2017
  • This paper presents the dynamic modeling, analysis, and control of an AC/DC/AC-assisted, self-excited induction generator connected to the grid. The dynamic model includes wind turbine models with pitch control, gear boxes, self-excited induction generators, excitation capacitance, inductive load models, controlled six-pulse rectifiers, and novel state-space models of a grid-connected inverter. The system has been simulated to verify its capabilities of buildup voltage, stator flux response, stator phase current, electromagnetic torque, and magnetizing inductance variation during both the dynamic and steady states with a variable-speed prime mover. The complete setup of the above dynamic models was simulated using MATLAB/SIMULINK.

Robust Decoupling Digital Control of Three-Phase Inverter for UPS (3상 UPS용 인버터의 강인한 비간섭 디지털제어)

  • Park, Jee-Ho;Heo, Tae-Won;Shin, Dong-Ryul;Roh, Tae-Kyun;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF