• 제목/요약/키워드: Normal value

검색결과 3,440건 처리시간 0.046초

우리나라 농경지토양(農耕地土壤)의 지형별(地形別) 이화학적(理化學的) 특성(特性) (Physico-chemical Properties of Soils Developed on the Different Topographies in Korea)

  • 현근수;박창서;정석재;문준
    • 한국토양비료학회지
    • /
    • 제22권4호
    • /
    • pp.271-279
    • /
    • 1989
  • 토양환경(土壤環境) 개량(改良)의 기초자료(基礎資料)인 토양(土壤)의 입경분포(粒徑分布) 및 몇가지 화학성(化學性)에 대(對)한 대표(代表)값을 지형별(地形別)(용암류태지(熔岩流台地) 제외(除外))로 파악(把握)하기 위하여 5,216개(個)(답(畓)3.075 그리고 전(田)2,140)의 시(市) 군(郡) 대표토양(代表土壤) 분석치(分析値)를 이용(利用) 전산(電算)처리하였다. 1. 논토양(土壤) 표토(表土)에서 대표(代表)값은 점토(粘土) 20.4%, pH 5.8, 유기물(有機物) 2.6%, CEC 10.4me/100g, 치환성(置換性) K 0.26me/100g 그리고 유효린산(有效燐酸) 89ppm이었다. 밭토양(土壤)에선 각각(各各) 17.3%, 5.5, 1.8% 9.1, 0.29me/100g 그리고 103ppm이었다. 2. 토양특성(土壤特性)은 지형(地形)에 따라 큰 차리(差異)를 나타내었다. 논토양(土壤) 표토(表土)에서 하해혼성평탄지(河海混成平坦地)는 점토(粘土) 21.4%, pH 6.0, 유기물(有機物) 2.2%, CEC 10.8me/100g, 치환성(置換性) K 0.39me/100g 그리고 유효인산(有效燐酸) 57ppm, 하성평탄지(河成平坦地)는 각각(各各) 15.3%, 5.7, 2.0%, 8.6me/100g, 0.17me/100g 그리고 76ppm, 곡간(谷間).선상지(扇狀地)는 각각(各各) 18.8%, 5.9, 2.7%, 10.4me/100g, 0.19me/100g 그리고 80ppm, 홍적태지(洪積台地)는 각각(各各) 20.0%, 5.7, 2.5%, 11.5me/100g, 10.26me/100g 그리고 91ppm, 산록경사지(山麓傾斜地)는 각각(各各) 21.5%, 5.7, 3.4%, 10.6me/100g, 10.27me/100g 그리고 141ppm이었다. 3. 밭토양(土壤) 표토(表土)의 경우(境遇) 하해혼성평탄지(河海混成坪坦地)는 점토(粘土) 5.5%, pH 5.7, 유기물(有機物) 1.1%, CEC 4.7me/100g, 치환성(置換性) K 0.17me/100g 그리고 유효린담(有效燐談) 50ppm, 하성평탄지(河成平坦地)는 각각(各各) 10.3%, 5.5, 1.4%, 7.6me/100g, 0.26me/100g, 그리고 160ppm, 곡간선상지(谷間扇狀地)는 각각(各各) 13.9%, 5.4, 1.8%, 9.3me/100g, 0.34me/100g 그리고 184ppm, 홍적태지(洪積台地)는 각각(各各) 29.87%, 5.3, 2.1%, 11.2me/100g, 0.40me/100g 그리고 58ppm, 산록경사지(山麓傾斜地)는 각각(各各) 20.0%, 5.7, 2.7%, 11.4me/100g, 0.32me/100g, 그리고 116ppm, 구릉지(丘陵地)는 각각(各各) 24.6%, 5.3, 1.8%, 10.2me/100g, 0.28me/100g, 그리고 51ppm 이었다. 4. 토양중(土壤中) 점토(粘土)을 제외(除外)하고는 pH, 유기물(有機物), CEC, 치환성(置換性) K 및 유효린산(有效燐酸)의 함양(含量)은 개량목표치(改良目標値)에 미달(未達)하였고 지형(地形)에 따라 큰 차리(差異)를 보였다. 5. 토양중(土壤中) 유기물(有機物), 치환성염기(置換性鹽基) 및 유효린산(有效燐酸)의 함양(含量)은 정규분포(正規分布)하지 않았으며, 토양특성(土壤特性)이 정규분포(正規分布)한다는 가정하(假定下)에 평균(平均)값의 68 및 95% 구간(區間)이 계산(計算)되었다.

  • PDF

두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가 (Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan)

  • 서성국;권동열;박세준;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.25-32
    • /
    • 2019
  • 목 적: 두경부 방사선 치료 시 Dental Implant에 의한 Metal Artifact로 인해 보철물의 크기, 모양 및 Volume이 달라지고 이로 인해 타겟 및 주변 정상조직에 대한 방사선치료계획의 정확성이 떨어진다. 본 연구는 치아크기를 재현한 Metal을 KVCT, SMART-MAR CT, MVCT를 통해 영상을 획득 하여 Volume을 평가하고 양성자 치료계획에 적용시켜 선량분포의 차이를 분석해 보고자 한다. 대상 및 방법: 치과에서 치료하는 방법을 고려하여 인레이, 크라운, 브릿지와 비슷한 크기의 A보철물($0.5{\times}0.5{\times}0.5cm$), B보철물($1{\times}1{\times}1cm$), C보철물($1{\times}2{\times}1cm$)을 저용융점납합금(Cerrobend, $9.64g/cm^3$) 사용하여 제작하였다. In House Head & Neck Phantom 안에 보철물를 위치시키고 CT Simulator(Discovery CT 590RT, GE, USA)를 이용해 Slice thickness 1.25 mm로 KVCT 영상과 SMART-MAR 영상을 획득하였다. MVCT 영상은 $RADIXACT^{(R)}$ Series(Accuray $Pricision^{(R)}$, USA)을 이용해 동일한 방법으로 획득하였다. MVCT, SMART-MAR CT, KVCT를 통해 획득한 보철물의 형상을 전산화 치료계획장비 Pinnacle(Ver 9.10, Philips, Palo Alto, USA)의 Autocontour Thresholds Raw Values를 통해 X, Y, Z축의 크기 및 Volume을 비교하였다. 양성자 치료계획은 위의 실험에서 얻은 보철물B($1{\times}1{\times}1cm$)의 각 CT별 치아 Contour를 KVCT 상에 fusion하여 양성자 치료계획(Ray station 5.1, RaySearch, USA)을 세우고 선량의 차이를 비교 평가하였다. 결 과: 실측 사이즈 대비 A보철물(MVCT : 1.0배, SMART-MAR CT : 1.84배, KVCT : 1.92배), B보철물(MVCT : 1.02배, SMART-MAR CT : 1.47배, KVCT : 1.82배), C보철물(MVCT : 1.0배, SMART-MAR CT : 1.46배, KVCT : 1.66배)로 각 크기의 보철물에서 MVCT가 가장 실제 Volume과 유사하게 측정되었다. 양성자 치료계획에서 B보철물의 Volume을 각각 적용하여 측정한 결과 $D_{99\%}$ volume의 선량이 기준 3082 CcGE 대비 MVCT:3094 CcGE, SMART-MAR CT:2902 CcGE, KVCT:2880 CcGE로 측정되었다. 결 론: 전체적인 Volume과 X축 Z축의 크기는 MVCT에서 실제 크기와 가장 일치했고 superior-Inferior방향인 Y축은 CT에 따라 차이 없이 길이가 일정했다. 두경부 양성자 치료 시 보철물의 크기, 모양 및 Volume이 비슷한 MVCT에서 가장 실제 값과 비슷한 선량분포를 보였고 MVCT를 이용한 보철물의 contour를 KVCT에 fusion하여 양성자치료계획에 적용 시 매우 유용할 것으로 사료된다.

스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식 (A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data)

  • 김길호;최상우;채문정;박희웅;이재홍;박종헌
    • 지능정보연구
    • /
    • 제25권1호
    • /
    • pp.163-177
    • /
    • 2019
  • 스마트폰이 널리 보급되고 현대인들의 생활 속에 깊이 자리 잡으면서, 스마트폰에서 수집된 다종 데이터를 바탕으로 사용자 개인의 행동을 인식하고자 하는 연구가 활발히 진행되고 있다. 그러나 타인과의 상호작용 행동 인식에 대한 연구는 아직까지 상대적으로 미진하였다. 기존 상호작용 행동 인식 연구에서는 오디오, 블루투스, 와이파이 등의 데이터를 사용하였으나, 이들은 사용자 사생활 침해 가능성이 높으며 단시간 내에 충분한 양의 데이터를 수집하기 어렵다는 한계가 있다. 반면 가속도, 자기장, 자이로스코프 등의 물리 센서의 경우 사생활 침해 가능성이 낮으며 단시간 내에 충분한 양의 데이터를 수집할 수 있다. 본 연구에서는 이러한 점에 주목하여, 스마트폰 상의 다종 물리 센서 데이터만을 활용, 딥러닝 모델에 기반을 둔 사용자의 동행 상태 인식 방법론을 제안한다. 사용자의 동행 여부 및 대화 여부를 분류하는 동행 상태 분류 모델은 컨볼루션 신경망과 장단기 기억 순환 신경망이 혼합된 구조를 지닌다. 먼저 스마트폰의 다종 물리 센서에서 수집한 데이터에 존재하는 타임 스태프의 차이를 상쇄하고, 정규화를 수행하여 시간에 따른 시퀀스 데이터 형태로 변환함으로써 동행 상태분류 모델의 입력 데이터를 생성한다. 이는 컨볼루션 신경망에 입력되며, 데이터의 시간적 국부 의존성이 반영된 요인 지도를 출력한다. 장단기 기억 순환 신경망은 요인 지도를 입력받아 시간에 따른 순차적 연관 관계를 학습하며, 동행 상태 분류를 위한 요인을 추출하고 소프트맥스 분류기에서 이에 기반한 최종적인 분류를 수행한다. 자체 제작한 스마트폰 애플리케이션을 배포하여 실험 데이터를 수집하였으며, 이를 활용하여 제안한 방법론을 평가하였다. 최적의 파라미터를 설정하여 동행 상태 분류 모델을 학습하고 평가한 결과, 동행 여부와 대화 여부를 각각 98.74%, 98.83%의 높은 정확도로 분류하였다.

두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가 (Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer)

  • 백민규;김민우;하세민;채종표;조광섭;이상봉
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.7-15
    • /
    • 2020
  • 목 적: 현대 방사선치료기술에서 종양표적위치 및 정상장기에 정확한 선량을 전달하기 위해 여러 방법의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 사용되고 있으며 그 중 선형가속기에 장착된 CBCT(Cone Beam Computed Tomography, CBCT)와 이외 장치인 ExacTrac(ExacTrac X-ray System)이 있다. 두 시스템을 비교한 이전 연구들에서는 Offline-review 이용하여 후향적으로 팬텀 및 환자의 Set-up 오차를 분석하거나 X, Y, Z 축과 하나의 회전방향(Couch Rotation)으로만 연구되어졌다. 본 연구에서는 Head and Neck Cancer 환자를 대상으로 CBCT와 ExacTrac을 이용하여 한 치료중심센터에서 각각 6 DoF(Degree Of Freedom) IGRT를 시행한 후, 두 IGRT 장비에서 나타난 팬텀 및 환자의 Set-up 오차, 환자 Set-up에 걸리는 시간, 노출 방사선량의 비교를 통해 유용성을 평가하고자 한다. 대상 및 방법: Rando Phantom을 이용하여 환자 움직임을 배제한 상태의 Set-up 오차 평가와 Head and Neck Cancer 환자의 Set-up 오차 값 두 가지 경우로 나누어 획득하였다. 노출 방사선량 평가는 유리선량계로 하였다. 환자 Set-up 후 IGRT 시행하는데 소요되는 시간을 평가하기 위해 Head and Neck Cancer 환자 11명을 대상으로 하였다. 총 치료기간동안 환자 당 평균 10회의 CBCT와 ExacTrac 영상을 동시에 얻었고, 관심영역지정(Region Of Interest, ROI) 설정 후 6D 온라인 자동위치교정(Online Automatching) 값의 차를 6개의 축(Translation group: SI, AP, LR; Rotation group: Pitch, Roll, Rtn)으로 각각 계산하였다. 결 과: Phantom과 환자에서 Set-up 오차는 Translation group에서 1mm 미만, Rotation group에서 1.5° 미만의 차이가 보였으며, Rtn 값을 제외한 다른 모든 축의 RMS 값이 1mm, 1° 미만으로 나타났다. 각 시스템에서 최종적으로 Set-up 오차 교정까지 걸리는 시간은 CBCT를 이용한 IGRT에서는 평균 256±47.6sec, ExacTrac을 이용 시 평균 84±3.5sec로 각각 나타났다. 1회 치료 당 IGRT에 의한 방사선 노출선량은 Head and Neck 부위 7곳의 측정위치 중 Oral Mucosa에서 CBCT와 ExacTrac이 각각 2.468mGy, 0.066mGy로 상대적으로 ExacTrac에 비해 피폭선량이 37배 높게 측정되었다. 결 론: CBCT와 ExacTrac 두 시스템 간의 6D 온라인 자동위치교정을 통해 Set-up 오차는 두 시스템의 자체적인 Systematic error 뿐 아니라, 환자 움직임(Random error)를 포함한 Set-up 오차가 1mm, 1.02° 미만으로 나타났다. 이는 본원에서 Head and Neck IMRT 치료 시 PTV Margin이 3mm이라는 것을 고려했을 때, 이 오차범위는 합리적으로 사료된다. 하지만 치료기간 동안 환자체중변화로 인한 따른 표적, 손상위험장기의 변화를 고려했을 때 CBCT와 적절히 병용하여 사용하는 것이 좋을 것으로 사료된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교 (Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma)

  • 강신창;박훈희;김정열;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.3-8
    • /
    • 2010
  • $^{11}C$-Acetate PET/CT는 간에 관련된 병변을 찾아내는데 있어 유용성이 있으며, 이에 대한 예민도는 87.3%에 이른다. 이에 반해 $^{18}F$-FDG PET/CT의 예민도는 47.3%이며, $^{18}F$-FDG와 $^{11}C$-Acetate PET/CT 검사를 동시에 사용하는 경우 예민도는 100%로 보고된바 있다. 하지만 $^{11}C$-Acetate PET/CT검사에서 췌장, 비장의 정상섭취로 인해 $^{18}F$-FDG PET/CT검사에 영향을 줄 수 있어 정확한 진단에 혼란을 야기시킬 수 있다. 본 연구는 이러한 두 방사성의약품의 사용으로 인하여 영상에 얼마나 영향을 주는지에 대해 당일 검사법과 양일 검사법 간의 비교 분석을 통해 유용성을 확인하는데 목적이 있다. 본 연구는 2007년 12월부터 2009년 7월까지 본원에서 간암 진단을 받고 PET/CT 검사를 시행한 환자 46명을 대상으로 하였다(남자 35명, 여자 11명, 평균연령: $54{\pm}10.6$세, 연령 범위: 29~69세). 검사에 이용된 장비는 Biograph TruePoint 40 PET/CT이며, 당일 검사법으로 검사한 21명에게는 $^{11}C$-Acetate PET/CT 검사를 먼저 시행하고 약 1시간 후에 곧바로 $^{18}F$-FDG PET/CT 검사를 시행하였다. 양일 검사법으로 검사를 시행한 25명에게는 1일째 $^{11}C$-Acetate PET/CT검사를 시행하고, 2일째 $^{18}F$-FDG PET/CT 검사를 시행하였다. 두 검사법 간의 $^{18}F$-FDG 영상에서 췌장과 비장에 동일한 관심영역을 설정하고 표준섭취계수를 측정하여 비교 평가하였다. 통계 분석은 SPSS Ver. 17을 사용하였으며, unpaired t-test를 통하여 두 검사법 간의 통계적 유의성을 확인하였다. 각각의 검사법으로 시행한 환자의 영상을 분석한 결과, 양일 검사법으로 검사를 시행한 환자의 췌장 부분의 표준섭취계수 평균${\pm}$표준편차는 두부 $1.62{\pm}0.32$ g/mL, 체부 $1.57{\pm}0.37$ g/mL, 미부 $1.49{\pm}0.33$ g/mL, 비장은 $1.53{\pm}0.28$ g/mL였다. 당일 검사법으로 검사를 시행한 환자의 췌장은 두부 $1.65{\pm}0.35$ g/mL, 체부 $1.58{\pm}0.27$ g/mL, 미부 $1.49{\pm}0.28$ g/mL, 비장은 $1.66{\pm}0.29$ g/mL로 나타났다. 당일 검사법과 양일 검사법 간의 췌장과 비장에서의 표준섭취계수는 통계적으로 유의한 차이를 보이지 않았으며 (p<0.05), PET/CT 영상분석에서도 위양성으로 오인할 수 있는 높은 섭취는 보이지 않았다. 본 연구를 통해서 하루 동안 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사를 시행하여도 $^{18}F$-FDG 영상에서 $^{11}C$-Acetate의 영향으로 인해 표준섭취계수의 과대평가가 일어나지 않는다는 것을 알 수 있었고 이는 표준섭취계수의 측정값을 통해 통계적으로 유의성을 확인할 수 있었다. 앞으로 $^{11}C$-Acetate가 상용화될 경우 $^{18}F$-FDG와 당일 검사법을 이용하여 간질환의 진단에 있어 PET/CT 검사의 진단능을 향상시킬 수 있고 위 결과를 토대로 두 방사성의약품의 간섭영향 없이 하루에 검사를 완료할 수 있으며, 대기시간을 단축하여 환자의 만족도를 높일 수 있을 것으로 사료된다.

  • PDF

편액과 시문으로 본 요월정원림(邀月亭園林)의 입지 및 조영 해석 (The Location and Landscape Composition of Yowol-pavilion Garden Interpreted from Tablet & Poetry)

  • 이현우;김상욱;임근홍
    • 한국전통조경학회지
    • /
    • 제32권3호
    • /
    • pp.32-45
    • /
    • 2014
  • 본 연구는 편액과 시문이 과거 누정원림의 고유한 입지 및 조영 특성 추론의 중요한 준거(準據)가 된다는 전제 하에, 요월정원림(邀月亭園林)을 대상으로 과거 시점의 입지 및 조영 해석을 고구(考究)하기 위해 시도되었다. 요월정원림이 갖는 의미와 문화재적 위상과 가치의 진정성 제고 및 보존의 당위성을 논의할 목적으로 시도된 연구결과는 다음과 같다. 첫째, 요월정원림은 정원주 김경우(金景遇)를 비롯한 당대 거유들이 교유한 시율풍류의 현장이었다. "조선환여승람 호남읍지(湖南邑誌) 장성읍지(長城邑誌)" 등 고문헌을 통해 사화(士禍)를 피해 머문 은신처로서의 성격과 함께 지역정체성을 형성한 교두보로서의 장소성이 확인되었다. 또한 "요월정원운(邀月亭原韻)"을 통해 누정원림 작정(作庭) 의도 및 조영 동기를 확인한 바, 요월정원림은 세속과 탈속 그리고 현실과 이상이 뒤섞여 길항(拮抗)한 공간으로 해석된다. 둘째, 당호 요월(邀月)은 누정에서 조망했을 때의 승경적 요인 및 자연현상과 관련된 명칭으로, 마주한 '월봉산에 뜨는 달을 맞이함'을 함의하는 어휘로, 이는 자연의 섭리이자 풍류로서 탈속의 이미지와 맞닿아 있다. 즉 요월정은 세속의 희비를 벗어나 자연의 섭리를 따르려한 조영 의도를 반영한 당호로 해석된다. 셋째, 요월정원림의 입지는 "영광속수여지승람(靈光續修輿地勝覽)"을 통해 조영자가 퇴관 후 휴식을 위해 마련한 처소였으며, 월봉산을 마주하여 황룡강(黃龍江)이 굽이쳐 흐르던 승경지였음을 고문헌과 다수의 시문을 통해 확인하였다. 특히, 수호인 인터뷰에 따르면 요월정원림에서 야경의 시지각 빈도(頻度)는 수호인 거처인 고직사에서 요월정을 향해 황룡강 방향인 동쪽을 숙시각(熟視角)으로 조망했을 때가 가장 높다고 한다. 또한 시지각 강도(强度)가 가장 높고 아름다운 풍경은 요월정 좌측 배후면에서 달이 부상하여 요월정 전면(前面)의 배롱나무동산을 가로질러 요월정과 마주한 월봉산 사이에 남중한 때로 증언한 바 있다. 현재 요월정원림의 좌향은 $SE\;141.2^{\circ}$로서 거의 남동향 하고 있는데, 이와 같은 요월정 좌향 설정은 지형조건뿐 아니라 달의 궤적을 유상(遊賞)하기에 최적화된 방향과 시계(視界)를 확보하기 위한 기도(企圖)가 담겼다고 판단된다. 나아가 전면의 황룡강 수면 위로 남중한 달빛이 투영됨으로써, 하늘의 달과 황룡강 강물에 투영된 달이 동시에 감지되게끔 고려된 것으로 추론된다. 넷째, 현재 요월정원림은 요월정과 광산김씨문숙공파종회각(光山金氏文肅公派宗會閣) 및 고직사(庫直舍)로 구성된 '내원 권역'과 진입부를 아우른 배롱나무동산 및 소나무 배후림이 포함된 '외원 권역'으로 구분된다. 나아가 '용소 및 수생식물원 권역' 및 최근 조성된 '황룡정과 공원 권역'으로 외연(外緣)이 확산되면서 교란되고 변용되었다. 다섯째, 조영 당시 요월정원림은 누정에서 조망한 풍경을 안아 들여 누정을 중심으로 지근거리의 일정한 자연을 점유한 방식인 '경계 없는 산수원림'이었으나, 현재 복합경관은 과거 원형경관과는 괴리된 '이질화 분절화 파편화된' 경관으로 파악된다. 마지막으로, 요월정원림이 문화재지정보호구역임을 감안할 때, 편액과 기문에 묘사된 완전한 원형경관으로의 복원은 아니더라도 최소한 원림권역에서의 경관적 악영향과 시각적 훼손을 최소화하기 위한 대책수립이 요망된다.

내독소처치 흰쥐에서 Tumor Necrosis Factor-$\alpha$치 상승에 따른 폐손상 악화 및 35 kDa 단백질 합성 (Lung Injury Indices Depending on Tumor Necrosis Factor-$\alpha$ Level and Novel 35 kDa Protein Synthesis in Lipopolysaccharide-Treated Rat)

  • 최영미;김영균;권순석;김관형;문화식;송정섭;박성학
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권6호
    • /
    • pp.1236-1251
    • /
    • 1998
  • 연구배경 : 급성폐손상의 병태생리학적 기전에는 염증세포들이 분비하는 다양한 염증성 매개물질들이 매우 중요한 역할을 한다. 이중 특히 tumor necrosis factor-$\alpha$ (TNF-$\alpha$) 는 다른 염증세포들의 화학주성 및 각종 염증성 매개물질 분비에 영향을 미치는 proin-flammatory cytokine으로 작용하는 한편, 직접적으로 세포손상을 야기시키는 세포독성 cytokine으로도 작용하는데, 급성폐손상에서 TNF-$\alpha$와 폐조직 손상과의 직접적인 관련성에 대해서는 아직 구체적으로 확인된 바가 많지 않다. 또한, 최근에 생체내 방어기전으로 스트레스 단백질에 대한 관심이 높아지면서, 단핵구에 내독소를 처치하거나, 동물에 내독소를 투여하기 전에 미리 스트레스 단백질을 합성시킨 경우, 내독소에 의한 손상을 감소시켜 준다는 연구가 보고되었지만, 내독소 자극 자체만으로 스트레스 단백질 합성이 유도되는지는 아직 분명하지 않다. 이에 저자들은 내독소 유도성 급성 폐손상에서 TNF-$\alpha$ 분비와 폐조직 손상을 포함한 일련의 염증반응과의 관계를 분석하고, 생체내 내독소 자극에 대하여 폐포대식세포에서 스트레스 단백질을 포함한 새로운 단백질 합성이 유도되는지 여부를 분석하고자 하였다. 연구방법 : 흰쥐의 기관내로 내독소를 투여한 후 시간별로 기관지폐포세척액내 TNF-$\alpha$농도, 염증세포 백분율 변화, 병리조직학적 소견을 관찰하고, 또한 각 시간대의 폐포대식세포에서 sodium dodesyl sulfate-polyacrylamide gel electrophoresis와 inducible heat stress protein72에 대한 면역화학염색을 시행하여 단백질 합성양상을 분석하는 한편, 폐포대식세포에 다양한 농도의 내독소 자극과 열처리를 가한 후, 배양상층액에서 tumor necrosis factor-a 농도를 측정하고, 폐포대식세포의 단백질 합성양상을 분석하였다. 연구결과 : 내독소 투여 후 tumor necrosis factor-$\alpha$는 첫 1시간째부터 현저하게 증가하여 (p< 0.0001) 3시간째 최고치에 이르렀고 6시간째는 감소하기 시작하여 12시간째는 정상 대조군 수준으로 감소하였다. 내독소 투여 후 염증세포 백분율의 변화는 2시간째부터 시작하여 6시간째 최고에 이르러 12시간째까지 지속하였으며, 장시간째에 정상 대조군 수준으로 회복하였다. 병리조직학적 소견상 폐손상 지표 점수는 내독소 투여후 6시간째 최고치에 이르러 24 시간째까지 지속하였다. 내독소 투여 후 분리한 폐포대식세포에서 첫 1시간째부터 장시간째까지 정상 대조군에서는 관찰할 수 없던 35kDa의 새로운 단백질 띠가 관찰되었으며, 면역화학염색상 inducible heat stress protein72는 관찰되지 않았다. 내독소 자극을 가하지 않은 정상 대조세포군에 비해 내독소 자극을 가한 세포군의 배양상층액에서 tumor necrosis factor-$\alpha$ 농도가 유의하게 높았으며 (p<0.001), 내독소 자극만 가한 세포군에 비해 열충격 전처치후 내독소 자극을 가한 세포군의 배양상층액에서 tumor necrosis factor-$\alpha$ 농도가 10 ${\mu}g/ml$ 내독소 자극군만 제외하고 모두 유의하게 감소하였다 (p<0.05). 내독소 자극만 가한 세포군은 10 ${\mu}g/ml$의 고농도에서만 35 kDa 의 단백질 띠가 합성되었고 inducible heat stress protein72는 관찰되지 않았다. 열충격 전처치후 내독소 자극을 가한 세포군은 모두 inducible heat stress protein72가 관찰되었다. 결 론 : 기관내 내독소 투여에 의한 급성 폐손상에서 tumor necrosis factor-$\alpha$는 폐손상 정도와 밀접한 관련이 있다. 또한 내독소 자극에 의해서는 폐포대식세포에서 inducible heat stress protein72 합성이 유도되지 않으며, 35 kDa의 새로운 단백질 합성이 유도되었는데, tumor necrosis factor-$\alpha$ 농도 및 병리조직소견과의 관계를 볼 때, 급성 폐손상에 있어 35 kDa 단백질이 방어적인 역할을 담당하지는 않을 것으로 보이며, 이에 대해서는 향후 더 연구가 필요할 것으로 생각된다.

  • PDF

남자 중.고생의 흡연과 음주습관이 영양소 섭취 및 건강상태에 미치는 영향 (Effect of Smoking and Drinking Habits on the Nutrient Intakes and Health of Middle and High School Boy Students)

  • 신경옥;안창훈;황효정;최경순;정근희
    • 한국식품영양과학회지
    • /
    • 제38권6호
    • /
    • pp.694-708
    • /
    • 2009
  • 본 연구는 서울시에 거주하는 남자 중 고생을 대상으로 흡연과 음주 현황을 조사하여 흡연 유무에 따라 비흡연군 (199명), 흡연군(11명), 흡연 음주군(52명)으로 분류하였으며, 설문을 통해 흡연과 음주습관, 식생활 관련사항 및 영양섭취상태 등을 조사하여 흡연과 음주습관이 식생활 습관, 영양소 섭취상태 및 건강상태에 어떠한 영향을 미치는지를 조사하였다. 전체 조사대상자의 신장 및 체중은 각각 $173.5{\pm}6.8\;kg$, $64.83{\pm}11.8\;cm$로 신장은 한국인 체위 기준치에 비해 1.5 cm 이상 더 컸으며, 체중은 1.0 kg 정도 높게 조사되었고, 전체 조사대상자의 체질량지수의 평균값은 $21.4{\pm}3.7\;kg/m^2$정도로 나타났다. 전체 조사대상자의 89% 이상이 건강에 대해 관심이 있는 것으로 조사되었으며, 43.5%의 청소년이 자신만의 건강유지 비결로 규칙적인 운동을 가장 많이 손꼽았다. 또한 66.0%의 청소년이 실제로 운동을 하고 있었으며, 일주일에 평균 3번 정도한다고 답한 전체 응답자는 37.3%로 가장 많은 비율을 차지하였다. 1회 운동 시 평균 운동시간은 30분${\sim}$1시간 정도가 가장 많은 비율(46.3%)을 차지하였다. 흡연자 63명 중 음주를 하는 학생이 52명 82.5%이었으며, 11명 17.5%만은 흡연만 하여 본 연구결과에서 보면, 흡연을 하는 경우 음주를 동시에 하는 것으로 조사되었다. 55.6%의 남자 중 고생은 중학교 때 흡연을 시작하였으며, 흡연 동기는 38.1%가 호기심으로 시작했다고 답하였다. 특히 배고플 때 흡연욕구를 강하게 느꼈으며, 흡연 장소로는 화장실이라고 답하였다. 흡연기간은 6개월에서 1년 사이가 가장 많은 비율을 차지하였고, 하루 흡연량은 하루에 $5{\sim}10$개피를 핀다고 답한 비율이 가장 많이 차지하였다. 금연을 하기 위해 시도했던 방법으로는 그냥 참은 경우가 69.0%였으며, 금연에 실패한 이유로는 의지부족이 44.4%로 가장 많은 비율을 차지하였다. 금연의 의향을 묻는 질문에는 전체 조사대상자의 87.1%가 금연을 하고 싶다고 답하였으나, 금연 프로그램을 실시하면 참여하겠느냐는 질문에는 단지 56.7%만이 참여하길 원하였다. 흡연 음주군에서 음주 시작 시기는 50.0%가 고등학교 때 시작하였으며, 사교적 필요성에 의해서 음주를 시작하였다고 답하였다. 음주는 주로 지정된 장소에서 하였으며, 조사대상자의 반 이상의 남자 중 고생이 한 번에 마시는 술의 양은 소주 한 병이하라고 답하였다. 음주의 욕구를 강하게 느낄 때는 친구가 술을 먹을 때라고 답하였으며, 금주 의향을 묻는 질문에는 단지 40.4%만이 금주를 하겠다고 답하였다. 34.4%의 아동이 매일 아침식사를 하는 것으로 조사되었으며, 아침식사를 전혀 하지 않는 결식률도 16.4%나 되었다. 아침식사를 거르는 이유로는 47.0%가 '아침시간이 바빠 시간이 없어서'라고 답하였으며, 건강상의 문제를 고려해 볼 때 결식의 방안을 마련하는 것이 시급한 과제라고 사료된다. 과식을 하는 이유로는 전체 조사대상자의 52.5%가 좋아하는 음식이 많아서 과식을 하는 것으로 조사되었으며, 흡연 음주군에서 과식을 자주하는 것으로 나타났다(p<0.05). 간식의 경우 하루에 $1{\sim}2$회 한다는 전체 청소년의 비율이 72.6%를 차지하였으며, 간식으로 섭취하는 식품으로는 비흡연군에서는 빵류 및 감자 40.2%, 패스트푸드 및 튀김식품을 30.7%로 많이 섭취하고 있었으며(p<0.05), 흡연군에서는 탄산음료 및 빙과류를 간식으로 섭취하는 비율이 36.4%나 되었고, 흡연 음주군에서는 과일류(38.5%)와 패스트푸드 및 튀김식품(26.9%)을 간식으로 가장 많이 섭취하는 것으로 조사되었다. 남자 중 고생이 주식으로 섭취하는 탄수화물 식품의 섭취비율 중 비흡연군에서는 다른 군에 비해 잡곡과 현미를 각각 45.7%와 36.2%로 유의하게 높았다(p<0.05). 흡연 음주군에서는 과일을 자주 섭취하는 비율이 9.6%로 매우 낮았으며(p<0.05), 50.0%가 패스트푸드를 섭취하는 것으로 조사되었다. 식생활 평가에서는 흡연군에서 삼겹살, 갈비 등 지방이 많은 육류를 주 2회 이상 먹는 비율이 높았으며, 아이스크림이나 과자, 탄산음료를 주 2회 이상 간식으로 자주 먹는 비율도 54.3%로 유의하게 높았다(p<0.05). 전체적인 영양소 섭취상태는 $15{\sim}19$세 청소년의 영양섭취기준에 제시한 기준치에 비해 현저히 높았으며, 열량 섭취의 경우 비흡연군에 비해 흡연군과 음주 흡연군에서 유의하게 높았다(p<0.05). 특히 흡연 음주군에서는 다른 군에 비해 인이 유의하게 높은 것으로 조사되었으며(p<0.05), 콜레스테롤(p<0.05)과 소디움(p<0.05) 섭취량은 흡연군에서 가장 높았다. 본 연구결과 청소년들이 흡연과 음주를 하게 되는 가장 큰 이유가 친구나 학교 선 후배 등 또래 집단의 영향을 받는 것으로 조사되었으며, 충동적인 호기심에 의해 시작하는 경우가 많아 흡연과 음주가 건강에 미치는 유해성에 대한 인식이 부족하였다. 또한 흡연을 하는 경우 음주를 동시에 하는 남자 중 고생이 82%가 넘는 것으로 나타나 청소년들의 흡연과 음주 실태는 심각한 사회 문제라 할 수 있으며, 식생활 습관도 음주 흡연군에서는 과일 섭취가 낮은 반면 고열량 식품 선호 및 과식을 하는 것으로 조사되었고, 흡연군에서는 육류 및 가공식품등의 섭취가 높았다. 따라서 선행연구(6)에서도 지적했듯이 친구들의 흡연과 음주의 권유를 단호하게 거절할 수 있는 대처방법을 습득시키거나 흡연과 음주의 욕구를 느낄 때의 실질적인 대처 수단 및 금연을 하는 구체적인 방법 등의 현실적인 교육이 필요하다고 사료된다. 흡연과 음주로 인해 발생되는 편식이나 과식 등의 잘못된 식습관을 바로 잡아 청소년의 성장 발달에 도움을 줄 수 있는 균형적인 영양섭취가 중요하며, 영양적인 중요성을 인식할 수 있는 교육도 뒷받침되어야 할 것이다. 또한 청소년 시기에 먹거리의 중요성을 인식시켜 건강에 유익하고, 안전한 식품을 선택할 수 있는 감각을 습득시키는 것도 중요할 것으로 사료된다.