• Title/Summary/Keyword: Normal Condition

Search Result 3,198, Processing Time 0.028 seconds

A Study on the Survey of Production Condition of Jeans in Casual Brands (캐주얼 브랜드의 청바지 생산 실태 조사에 관한 연구)

  • Uh, Mi-Kyung;Suh, Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.4
    • /
    • pp.702-712
    • /
    • 2007
  • The purpose of this study was to understand the current trend with regard to the material of jeans and the making method of jeans pattern and the characteristics of washing processing through the overall production status of jeans in casual brands and to offer the basic data for producing the high efficient jeans. The results were as follows. According to the survey of production status of jeans in casual brands, the fabric mixture was highest in the order of non-stretch denim 100% cotton, stretch denim cotton/spandex mix and denim with $1{\sim}2%$ weft direction spandex mix. The most frequently used processing method for denim was in the order of normal finishing, mercerization finishing, soft finishing and pigment finishing. The most frequently used method of washing finishing for jeans was in the order of forming by embossing washing, bio stone washing, normal washing, bio washing, and bio stone bleach washing. The average shrinkage was higher on waist circumference and pants length of warp direction rather than hips circumference, thigh circumference, hem circumference of weft direction.

  • PDF

Differentiation of tidal volume & mean airway pressure with different Bag-Valve-Mask compression depth and compression rate (Bag-Valve-Mask의 사용방법에 따른 일회호흡량과 평균기도압의 변화 연구)

  • Jo, Seung-Mook;Jung, Hyung-Keon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.67-74
    • /
    • 2012
  • Purpose : The purpose of this study is to get basal user guidelines of safer bag-valve-mask application on patient with normal pulmonary patho-physiologic condition. Methods : This study was accomplished by pre-qualified 25 EMS junior grade students. Participants were instructed randomly compress bag to one-third, half and total and also with differesnt compression speed. Resultant tidal volumes and mean airway pressures obtained in RespiTrainer were analysed in relation to the each compression depth and rate. Results : Demographic difference does not affect tidal volume with any compression depth and rate change. Increasing compression depth is correlated with tidal volume increasement at any compression rate and also with mean airway pressure. If the compression depth is same, compression rate change did not affect significantly the resultant tidal volume or mean airway pressure. Conclusion : Hand size, Experience, BMI dose not affect tidal volume. Compress the 1600 ml bag half to total amount is safe way to offer sufficient tidal volume without risky high airway pressure delivery to patient airway who with normal lung patho-physiologic condition.

Target Altitude Extraction for Multibeam Surveillance Radar in Normal Environmental Condition (정상 환경 상태에서 다중 빔 탐색 레이다의 표적 고도 추출)

  • Chung, Myung-Soo;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.9
    • /
    • pp.1090-1097
    • /
    • 2007
  • The multibeam surveillance radar is a state-of art of 3D radar technology. It applies the stacked beam-on-received realized by a digital beamformer. In this paper, a design concept of beamformer and a method of target altitude extraction for multibeam surveillance radar in the normal environmental condition considering no multipath situations are proposed and investigated. The extraction algorithm based on antenna sine space coordinated system in a FFT digital beamformer is described. The proposed algorithm is simulated by 1 look-up table data and confirmed to have consistent results in accordance with a variety of target altitudes and a full radar frequency range.

A Study on Stability of Ag sheathed Bi-2229 tape and Cylindrical Stacking Conductor for HTS Cable (고온초전도 케이블용 은시스 Bi-2223 테이프 및 적층 도체의 안정성연구)

  • Lee, B.S.;Kim, Y.S.;Jang, H.M.;Back, S.M.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1554-1556
    • /
    • 2000
  • Normal zone propagation(NZP) characteristics were investigated on Ag sheathed multi filamentary Bi-2223 tape and cylindrical stacking conductor. The critical current($I_c$) of Ag sheathed Bi-2223 tape and cylindrical stacking conductor were 12 A, 63 A at 77 K, 0 T. Normal zone propagation(NZP) experiments with tape were conducted with refrigerator in temperature from 45 K to 77 K, 0 T. Cylindrical stacking conductor was molding with epoxy and experiments were conducted with adiabatic condition in $LN_2$. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. Temperature ($T_1$) of tape with distance of 0.5 cm from heater was strongly climbed up to 95K and slowly decreased. NZP velocities of cylindrical stacking conductor were 1.9-2.4 cm/sec in $LN_2$.

  • PDF

The Study Trend and Problems of Propulsion System in a Zero-gravity Environment (무중력 환경에서 추진기관의 문제점 및 연구 동향)

  • Kil, Gyoung-Sub;Lim, Ha-Young;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.573-576
    • /
    • 2010
  • The propulsion systems such as upper stages of launch vehicles, orbiters, spacecrafts have to operate in the zero gravity environment. Because the flight condition where the vehicle undergoes is different from the normal gravity state, many studies have been being in progress. Fluid behavior in the zero gravity condition is differently shown in the normal gravity state because the importance of the intermolecular force, such as adhesion, cohesion, and surface tension is enlarged. In this paper, we investigate the characteristic of fluid behavior and describe effects and problems on the liquid propulsion system due to these fluid behavior. We also check which studies are in progress in order to solve these problems.

  • PDF

A Study on the Friction Characteristics of Vulcanized Natural Rubber Plate (가황된 천연고무 판재의 마찰특성에 관한 연구)

  • Kim, D.J.;Nah, C.;Lee, Y.S.;Kim, W.D.
    • Elastomers and Composites
    • /
    • v.36 no.2
    • /
    • pp.121-129
    • /
    • 2001
  • The friction characteristics of natural rubber plates under various conditions including sliding speed, normal force, hardness, lubrication conditions and thickness of plate are analyzed experimentally. The frictional force and normal force are measured by a tester pin and a load ceil with strain gages. Experimental results suggest that the coefficient of friction decreases with increasing the hardness of rubber and decreasing the thickness of plate. The effect of sliding speed is not significant over the speed range employed. The coefficient of friction is found to be about 0.1 under oil lubrication condition and varies from 0.9 to 3.9 under no lubrication condition.

  • PDF

Two-dimensional speckle-tracking of antral contraction in dogs

  • Park, Junghyun;An, Soyon;Hwang, Tae Sung;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.2
    • /
    • pp.55-59
    • /
    • 2020
  • This study was purposed to make the referenced range of stomach antral contraction strain in 50 dogs using 2-dimensional speckle tracking. In addition, the strain results were compared among body condition scores to reveal the correlations of obesity among the subjects of the study. Finally, the medetomidine group that was comprised of 10 dogs was compared with the normal group to identify the medetomidine pharmacologic effect in the stomach antral contraction. Clinically healthy 50 dogs were recruited for the study. In an ultrasonographic examination, the stomach antrum region was scanned, and at least one cycle of antral contraction was recorded. The peak strain of antral contraction in healthy dogs was 58.2 ± 20.47% (mean ± SD). The obesity group showed a high strain result and there were significant correlations between the body condition score (BCS) 2, BCS 3 groups and BCS 8 group. The medetomidine group revealed a low strain result and was significantly correlated with normal group. Two-dimensional speckle tracking was useful to the evaluation of stomach motility disorders.

The Performance & Operation Analysis of a Steam Reformer for MCFC (MCFC용 Steam Reformer 개질성능 분석 및 운전평가)

  • Seo, Hai-Kung;Koh, Joon-Ho;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.4
    • /
    • pp.149-159
    • /
    • 2000
  • This paper is concerned with the performence of a steam reformer for 25kW class MCFC, which is compared with the theoretically calculated results at various operating conditions. The theoretical $H_2$ production amount and $CH_4$ conversion rate are calculated with variations of temperature and steam/carbon (S/C) ratio using fortran program, and the actual values are measured from flowmeter and gas chromatography. As a result of the comparison of theoretical and actual values, the theoretical $H_2$ production amount is calculated by $24.4m^3/hr$ at the normal operating condition(LNG $9m^3/hr$, S/C ratio 5, absolute pressure $2.77kg/cm^2$, $610^{\circ}C$), but the actual production amount is only $19.4m^3/hr$, which is 79.5% of the theoretical value. Nevertheless, at the normal operating condition, the reformer for 25kW class MCFC performed well for a 2,100 hr long run operation, constantly producing $H_2$.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE REMOVING EFFICIENCY OF SMEAR LAYER BY K-FILE AND ULTRASONIC INSTRUMENT (K-FILE과 초음파 기구의 도말층제거효과에 대한 주사전자 현미경적 연구)

  • Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.97-105
    • /
    • 1994
  • The purpose of this study was to evaluate the smear layer removing efficiency of two root canal preparation techniques. Twelve single-rooted teeth were used in two groups of six each. Group 1 was biomechanically prepared by hand using a K-file with a high volume of normal saline irrigation. Group 2 was. prepared by using ultrasonically activated K-file with a constant high volume of normal saline irrigation. After the experimental procedures, each root was split saggitally. The removing efficiency of the preparation methods were assessed in terms of surface condition of the canal walls at three levels, those coronal, middle, and apical thirds. On the basis of remaining debris, presence of smear layer, and patency of dentinal tubules, each canal was evaluated according to a scale form 0 to 2. A statistical analysis was used to indicated any significant differences in surface condition between the two methods. There was no statistical significance between hand instrumentation and ultrasonic instrumentation at the cervical third but removing efficiency of ultrasonic instrumentation was superior. No statistically significant differences were obhserved for middle or apical third.

  • PDF

A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours (부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, In-Soo;Bae, Seok-Myung;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF