• Title/Summary/Keyword: Nonlinear optical microscopy

Search Result 22, Processing Time 0.027 seconds

Third-Harmonic Generation Microscopy for Material Characterization

  • Royon, Arnaud;Bousquet, Bruno;Canioni, Lionel;Treguer, Mona;Cardinal, Thierry;Fargin, Evelyne;Kim, Dae-Geun;Park, Seung-Han
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.188-195
    • /
    • 2006
  • Third harmonic generation microscopy is described in the frame work of the theory of harmonic generation with Gaussian focused beams inside a bulk material as well as at the vicinity of an interface. This model is then applied to characterize different types of materials in terms of electronic third-order susceptibility. Examples of bulk glasses, poled glasses, laser-induced modifications in glasses and nanoparticles in solution are given in order to give a survey of the broad application field of THG microscopy in material characterization.

Multimodal Nonlinear Optical Microscopy for Simultaneous 3-D Label-Free and Immunofluorescence Imaging of Biological Samples

  • Park, Joo Hyun;Lee, Eun-Soo;Lee, Jae Yong;Lee, Eun Seong;Lee, Tae Geol;Kim, Se-Hwa;Lee, Sang-Won
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.551-557
    • /
    • 2014
  • In this study, we demonstrated multimodal nonlinear optical (NLO) microscopy integrated simultaneously with two-photon excitation fluorescence (TPEF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) in order to obtain targeted cellular and label-free images in an immunofluorescence assay of the atherosclerotic aorta from apolipoprotein E-deficient mice. The multimodal NLO microscope used two laser systems: picosecond (ps) and femtosecond (fs) pulsed lasers. A pair of ps-pulsed lights served for CARS (817 nm and 1064 nm) and SHG (817 nm) images; light from the fs-pulsed laser with the center wavelength of 720 nm was incident into the sample to obtain autofluorescence and targeted molecular TPEF images for high efficiency of fluorescence intensity without cross-talk. For multicolor-targeted TPEF imaging, we stained smooth-muscle cells and macrophages with fluorescent dyes (Alexa Fluor 350 and Alexa Fluor 594) for an immunofluorescence assay. Each depth-sectioned image consisted of $512{\times}512$ pixels with a field of view of $250{\times}250{\mu}m^2$, a lateral resolution of $0.4{\mu}m$, and an axial resolution of $1.3{\mu}m$. We obtained composite multicolor images with conventional label-free NLO images and targeted TPEF images in atherosclerotic-plaque samples. Multicolor 3-D imaging of atherosclerotic-plaque structural and functional composition will be helpful for understanding the pathogenesis of cardiovascular disease.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

Azimuthal Angle Scan Distribution, Third Order Response, and Optical Limiting Threshold of the Bismarck Brown Y:PMMA Film

  • Fadhil Abass Tuma;Hussain Ali Badran;Harith Abdulrazzaq Hasan;Riyadh Chassib Abul-Hail
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.721-731
    • /
    • 2023
  • This paper studies various roughness parameters, besides waviness, texture, and nonlinear parameters of Bismarck brown Y (BBY)-doped Poly(methyl methacrylate) (PMMA) films based on the computed values of optical limiting (OL) threshold power and nonlinear refractive index. The films' morphology, grain size, and absorption spectra were investigated using atomic force microscopy in conjunction with ultraviolet-visible (UV-Vis) spectrophotometer. The particle size of the films ranged between 4.11-4.51 mm and polymer films showed good homogeneity and medium roughness, ranging from 1.11-4.58 mm. A polymer film's third-order nonlinear optical features were carried out using the Z-scan methodology. The measurements were obtained by a continuous wave produced from a solid-state laser with a 532 nm wavelength. According to the results, BBY has a nonlinear refractive index of 10-6 cm2/W that is significantly negative and nonlinear. The optical limiting thresholds are roughly 10.29, 13.52, and 18.71 mW, respectively. The shift of nonlinear optical features with the film's concentration was found throughout the experiment Additionally, we found that the polymer samples have outstanding capabilities for restricting the amount of optical power that may be transmitted through them. We propose that these films have the potential to be used in a wide variety of optoelectronic applications, including optical photodetectors and optical switching.

Construction of Langmuir trough and optical properties of phenylhydrazone dye LANGMUIR-BLODGETT films by attenuated total reflection (LANGMUIR-BLODGETT 박막 증착장치 제작 및 전반사감쇠법에 의한 Phenylhydrazone)

  • 고해석
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.193-198
    • /
    • 1990
  • We constructed Langmuir trough for the ultra-thin films (from a few tens {{{{ ANGSTROM }}) of nonlinear optical organic materials. Surface pressure - area isotherm for the tetracosanoic acid which is a fatty acids, was recorded and Langmuir -Blodgett films was deposited using it. The homogenity was investigated using scanning electron microscopy (SEM).

  • PDF

Identification and Correction of Microlens-array Error in an Integral-imaging-microscopy System

  • Imtiaz, Shariar Md;Kwon, Ki-Chul;Alam, Md. Shahinur;Hossain, Md. Biddut;Changsup, Nam;Kim, Nam
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.524-531
    • /
    • 2021
  • In an integral-imaging microscopy (IIM) system, a microlens array (MLA) is the primary optical element; however, surface errors impede the resolution of a raw image's details. Calibration is a major concern with regard to incorrect projection of the light rays. A ray-tracing-based calibration method for an IIM camera is proposed, to address four errors: MLA decentering, rotational, translational, and subimage-scaling errors. All of these parameters are evaluated using the reference image obtained from the ray-traced white image. The areas and center points of the microlens are estimated using an "8-connected" and a "center-of-gravity" method respectively. The proposed approach significantly improves the rectified-image quality and nonlinear image brightness for an IIM system. Numerical and optical experiments on multiple real objects demonstrate the robustness and effectiveness of our proposed method, which achieves on average a 35% improvement in brightness for an IIM raw image.

Synthesis and Properties of Novel T-type Nonlinear Optical Polyurethane Containing Tricyanovinylthienyl Group with Enhanced Thermal Stability of Dipole Alignment

  • Cho, You-Jin;Kim, Mi-Sung;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.424-430
    • /
    • 2011
  • A novel T-type polyurethane 7 containing 1-(2,5-dioxyphenyl)-2-(5-(1,2,2-tricyanovinyl)-2-thienyl)ethenes as NLO chromophores, which constitute part of the polymer backbone, was prepared. Polyurethane 7 is soluble in common organic solvents such as DMF and DMSO. It shows a thermal stability up to $270^{\circ}C$ from TGA thermogram with $T_g$ value obtained from DSC thermogram near $155^{\circ}C$. The second harmonic generation (SHG) coefficient ($d_{33}$) of poled polymer film at 1560 nm fundamental wavelength is $3.56{\times}10^{-9}$ esu. Polymer 7 exhibits a thermal stability even at $5^{\circ}C$ higher than $T_g$, and no significant SHG decay is observed below $160^{\circ}C$, which is acceptable for nonlinear optical device applications.

Near Infrared Femtosecond Laser and Its Two-photon Bio-imaging Technology (근적외선 펨토초 레이저 및 이광자 바이오 영상 기술)

  • Song, D.H.;Seo, H.S.;Lee, S.K.;Huh, C.;Park, S.J.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • Over the last three decades, the development of Ti:sapphire femtosecond lasers has led to advancements in scientific and industrial fields. In particular, these advanced lasers show great potential for applications with bio-imaging and medical surgery, such as two-photon microscopy, nonlinear Raman microscopy, optical coherence tomography, and ophthalmic surgery. Herein, we present a detailed description of the theoretical and experimental physics of Kerr-lens mode-locked femtosecond Ti:sapphire lasers and its two-photon microscopy.