• Title/Summary/Keyword: Non-Newtonian

Search Result 331, Processing Time 0.023 seconds

Computation of viscoelastic flow using neural networks and stochastic simulation

  • Tran-Canh, D.;Tran-Cong, T.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.4
    • /
    • pp.161-174
    • /
    • 2002
  • A new technique for numerical calculation of viscoelastic flow based on the combination of Neural Net-works (NN) and Brownian Dynamics simulation or Stochastic Simulation Technique (SST) is presented in this paper. This method uses a "universal approximator" based on neural network methodology in combination with the kinetic theory of polymeric liquid in which the stress is computed from the molecular configuration rather than from closed form constitutive equations. Thus the new method obviates not only the need for a rheological constitutive equation to describe the fluid (as in the original Calculation Of Non-Newtonian Flows: Finite Elements St Stochastic Simulation Techniques (CONNFFESSIT) idea) but also any kind of finite element-type discretisation of the domain and its boundary for numerical solution of the governing PDE's. As an illustration of the method, the time development of the planar Couette flow is studied for two molecular kinetic models with finite extensibility, namely the Finitely Extensible Nonlinear Elastic (FENE) and FENE-Peterlin (FENE-P) models.P) models.

Element-free simulation of dilute polymeric flows using Brownian Configuration Fields

  • Tran-Canh, D.;Tran-Cong, T.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 2004
  • The computation of viscoelastic flow using neural networks and stochastic simulation (CVFNNSS) is developed from the point of view of Eulerian CONNFFESSIT (calculation of non-Newtonian flows: finite elements and stochastic simulation techniques). The present method is based on the combination of radial basis function networks (RBFNs) and Brownian configuration fields (BCFs) where the stress is computed from an ensemble of continuous configuration fields instead of convecting discrete particles, and the velocity field is determined by solving the conservation equations for mass and momentum with a finite point method based on RBFNs. The method does not require any kind of element-type discretisation of the analysis domain. The method is verified and its capability is demonstrated with the start-up planar Couette flow, the Poiseuille flow and the lid driven cavity flow of Hookean and FENE model materials.

Experimental Study on Viscous Fluid Damper for Seismic Base Isolation System (점성감쇠형 면진장치에 관한 실험적 연구)

  • 정민기;박진일;권형오;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.590-595
    • /
    • 1998
  • This study was performed to obtain a numerical model for a viscous fluid damper from an experimental testing. The input signals for displacement were chosen as two type : a triangular and a sinusoidal forms. The performing test parameters were the area of the resistant plate and the oil film thickness of the viscous fluid and the temperature effect was neglected. The numerical model was established by assuming to behavior as an non-Newtonian fluid. The test results were summarized by the equation of F = 0.0308A(V/d)$^{0.51}$25/. Using the obtainal formula, the procedure to apply the viscous damper for a real structure design was introduced..

  • PDF

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

A Study on the Color Reproduction of Halftone Image by used Factor N and Process Ink Characteristics (Factor N와 잉크특성을 고려한 망점화상의 색재현예측에 관한 연구)

  • 김성근
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.13-27
    • /
    • 1994
  • Litho printing ink vehicles based on rosin modified phenolic are faster drying, have better durability, are harder and glosser and have greater resistance to water than ones based on ester gums. Ink-Water balance and rheological properties are important in litho printing process. These physical properties is concerned with molecular weight of Resin to use vehicle. So this paper was studied about the effects of changing molecular weight of Rosin modified phenolic on surface tension, viscosity, pseudoplasticity and printablility of Litho Inks. The results were as follows. 1) The surface tension of model inks depended on the molecular weight of the resin : Dispersion componnent of ink increase but non dispersion component decrease as molecular weight of Resin increase. 2) Water pick-up of litho ink is more fast balance, using low molecular weight of Resin. 3) Viscosity, Yield value and Newtonian value of model inks increase as molecular weight of Resin increase. 4) The litho ink prepared with the modified phenolic of which molecular weight is about 20000 showed the highest printing density and gloss.

  • PDF

The Effect of Changing Molecular Weight of Rosin Modified Phenol Resin on Physical Properties of Litho Printing Inks (Rosin변성 phenol수지의 분자량 변화에 따른 평판인쇄 잉크의 물성변화에 관한 연구)

  • SungBinKim
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.145-157
    • /
    • 1994
  • Litho printing ink vehicles based on rosin modified phenolic are faster drying, have better durability, are harder and glosser and have greater resistance to water than ones based on ester gums. Ink-Water balance and rheological properties are important in litho printing process. These physical properties is concerned with molecular weight of Resin to use vehicle. So this paper was studied about the effects of changing molecular weight of Rosin modified phenolic on surface tension, viscosity, pseudoplasticity and printability of Litho Inks. The results were as follows. 1) The surface tension of model inks depended on the molecular \veight of the resin : Dispersion componnent of ink increase but non dispersion component decrease as molecular weight of Resin increase. 2) Water pick-up of litho ink is more fast balance, using low molecular weight of Resin. 3) Viscosity, Yield value and Newtonian value of model inks increase as molecular weight of Resin increase. 4) The litho ink prepared with the modified phenolic of which molecular weight is about 20000 showed the highest printing density and gloss.

  • PDF

A flow characteristic of non-newtonian fluid in coutte flow of concentric cylinder (동심원통속의 Coutte flow에 있어서 비 Newton 유체의 유동특성)

  • 권혁칠;이성노;부전유사
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.109-114
    • /
    • 1992
  • The purpose of this study is to experimentally research the effects of polymer additives on turbulent transition of Couette flow between concentric cylinders when outer one is rotating and inner one is at rest; the diameter ratio being 0.2. Aqueous polymer solution generate the degradation phenomena in machine forming work, but this is not effected in about 10 minute at 5ppm. aqueous polymer solution testing. The Reynolds number, referred to the gap distance and rotation velocity of the outer cylinder, of turbulent transition is about 20000 for water flow. In the laminer region, the torque value is as same as theoretical one in the region of low Reynolds number, but becomes high with an increase in the Reynolds number. The polymer additives reduce the Reynolds number for turbulent transtition. In the turbulent region, the torque is remarkably reduced by the polymer additives, soluble polymer take down effect of turbulent transition boundary torque.

  • PDF

The Study of FAA's certification policy for approving the ground use of deicing/anti-icing fluids on airplane (항공기용 결빙방지액의 지상 사용승인을 위한 FAA의 최근 인증정책 연구)

  • Kim, You gwang
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-57
    • /
    • 2013
  • This study describes the Federal Aviation Administration(FAA) certification policy for approving the use of Type II, III, and IV deicing/anti-icing fluids on small category airplanes. These fluids can be characterized as non-Newtonian, pseudo-plastic fluids, also known as "thickened" fluids. Deicing fluids are used before takeoff to remove frost or ice contamination, while anti-icing fluids are used before takeoff to prevent frost or ice contamination from occurring for a period of time(referred to as "holdover time") after application. Thickened deicing/anti-icing fluids can affect airplane performance and handling characteristics and their residue may cause stiff or frozen flight controls. This study also describes an approval process that may be used by type certificate holders and applicants for a type certificate under parts 23 to support operational use of these fluids on their airplanes.

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

Thin Film Elastohydrodynamic Lubrication of Nanometer Scale (나노미터 크기 유막에서의 탄성유체윤활)

  • 장시열
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.54-63
    • /
    • 1998
  • In many practical lubricated contacts such as a rough concentrated contact on the sliding of nominally flat surfaces, the fluid may be of molecular (nanometer) scale owing to the asperity interactions on the surfaces. Under this condition, there is insufficient lubricant on the concentrated contact spot to maintain a realistic continuum. Rheological behavior for this kind of concentrated contact has been studied extensively to know whether the application of viscous fluid model is appropriate. The interaction of two rough surfaces is simplified as perfectly flat-rough surfaces contact under certain conditions by "composite topography" and for a nanometer scale fluid film, three kinds of rheological fluid behavior are analyzed in elastohydrodynamic asperity point contact.t contact.