• 제목/요약/키워드: Noise regulation

검색결과 212건 처리시간 0.032초

도시철도 운행소음 저감용 훼어링시스템 연구 (A study on Fairing System for Traveling Noise Reduction in Urban Subway)

  • 최상춘;장원락;호경찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.659-666
    • /
    • 2009
  • As the density and height of the buildings nearby subway lines get higher, the unprecedented residents' appeals for noise are on the rise. Furthermore, in accordance with the revision of enforcement regulations on the Noise and Vibration Control Act, the night time noise standards have been reinforced by 5dB effective on January 1st 2010 and the appropriate measures shall be taken accordingly. For the settlement of the public grievances against noise and vibration generated on tracks in at-grade and elevated section, the installation of continuously-welded-rail, rail lubrication system, improved fastening system and higher noise barrier is currently executed. Nevertheless, the noise and vibration levels in some areas are still exceeding the limits required in the regulation. Among the measures, an installation of higher noise barrier or noise tunnel seems to be the most effective way; however, it has limitations owing to the structural stability of existing elevated structures. The paper in consideration of the local conditions and foreign practices discusses the installation of fairing system under the train body as an noise insulation panel in order to reduce the rolling noise and under-carriage noise. Based on the result of this study, a performance verification test during actual train operation is in progress for further study.

  • PDF

마이크로버스트를 통과하는 비행기의 안전착륙을 위한 자동조종장치 (Autopilot for Safe Landing in the Microburst)

  • 박기홍
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.605-612
    • /
    • 1997
  • A state feedback controller and an observer have been developed and analyzed for an aircraft's safe landing in the windshear called microburst. The observer estimates the ambient wind field as well as the full-order longitudinal state vector. The controller uses the wind and state estimates for guiding the control inputs for safe landing. For the observer and controller gains, the design methodologies of linear quadratic estimation and linear quadratic regulation have been exploited. Analysis shows that some of the microburst-induced aircraft accidents in the past might have been avoided with the designed autopilot.

  • PDF

A Potential Value of Noise Control in Construction Sites for Real Estate Developers

  • Zheng, Guo;Kim, Youngchul
    • KIEAE Journal
    • /
    • 제14권4호
    • /
    • pp.5-10
    • /
    • 2014
  • Since construction work is an indispensable part of daily lives, complaints of noise are unavoidable. Noise control in construction sites is normally known as a regulation by a government and self-motivated noise controls rarely occur. In this paper, a marketing strategy is proposed to provide a potential value of noise control for real estate developer. First, people's perception to construction noise was examined in means of collecting and analyzing media reports between 2005 to 2011. Then decibel test was done in order to test noise generated by different devices in a construction site in various distances. According to the theory of core competency, a conceptual model was raised to illustrate profit and loss situation of the real estate developers in the case they invest more in noise control. The construction noise is discussed that it will ruin people's perception to the company's brand image and reputation. Also, the investment in the creation of silent site is discussed that it will not only bring benefit to the brand image work but also have value of profit in the market.

공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구 (An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom)

  • 이태강;고광필;김항;송국곤;김선우
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

부유식 석유생산.저장.하역선박의 소음해석 (A Noise Prediction of Floating, Production, Storage and Offloading(FPSO))

  • 김영현;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

공동주택의 소음 저감재 설치로 인한 바닥 충격음에 관한 연구 (A Study on Floor Impact Sound due to Resilient Materials in Apartment Buildings)

  • 김병길;김수련;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.5-10
    • /
    • 2004
  • Apartment Buildings have particularity to cluster together, especially, floor is close to resident, it is subject to dissatisfaction about impact noise between up and down floors. However, we require standard for counterplan to reduce the impact noise of floor. In point of fact, it difficult to objective evaluate for performance sound insulation that not physical sound volume but orignal form, means and effect of sound caused to complex noise in apartment house. Unique type of dwelling and structure pattern cause to noise of floor impact which is established by law for standard regulation. It is object to analysis and compare the result of performance sound insulation of upper floor impact and sample construct the subject resilient material of sound insulator

  • PDF

고성능 바닥충격음 차단구조 개발에 관한 연구 (A Study on the Development of High Performance Floor Impact Noise Insulation System)

  • 장재희
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.71-76
    • /
    • 2007
  • For the many years the children's running noise has caused perpetual frictions between neighbors in apartment houses. For this reason the government established a regulation to reduce the floor impact noise, as a result almost all apartment houses have been enforced to use the floor structure with 210mm thickness concrete slab and 120mm thickness of floor heating system since July 2005. If do not want to apply this kind of system, a system which obtain the certification from the institution appointed by government must be applied. In this reason a lot of construction material companies and construction companies have been trying to develop the system with 180mm thickness concrete slab for the purpose of reducing the cost. To develop the optimized floor system, actual size test building were constructed and the materials related with reducing floor impact noise were composited and tested in the test building. Through this procedure the most effective system was found.

헤드셋 내부의 소음 감쇄를 위한 강인 제어기의 설계 (Design a Robust Controller to Attenuate Residual Noise in a Headset)

  • 정태진;박용식;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.555-557
    • /
    • 1999
  • This paper implements an active noise controller in a headset by solving Robust $H_{\infty}$ control problem. In the $H_{\infty}$ control framework, we can suppose the noise in a headset as disturbance and the noise control problem is cast on the well-known $H_{\infty}$ regulation problem. By representing the system as LFT(Linear Fractional Transformaion) form, the controller is obtained using D-K iteraitons. The designed controller was implemented with operational amplifiers and it produced the desired noise reduction performance.

  • PDF

방음벽 안전을 위한 기준 조사 및 분석 (Investigation and Analysis of Regulations for the Safety of the Noise Barrier)

  • 허영;김흥식
    • 한국소음진동공학회논문집
    • /
    • 제13권9호
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.