• 제목/요약/키워드: Noise measurement

검색결과 3,217건 처리시간 0.03초

급수기구 발생음의 실험실 측정방법 제1부 : 측정방법 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement)

  • 양관섭;정갑철;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.845-850
    • /
    • 2003
  • Noise caused by water installations may lead to annoyance in adjacent rooms, for example in dwellings. hospitals and hotels. This part of standard describes a method of measurement allowing comparable results to be obtained in laboratory measurements. The test conditions described herein constitute the standard reference conditions essential for comparisons between laboratories.

  • PDF

A Comparative Study of the Methods to Assess Occupational Noise Exposures of Fish Harvesters

  • Burella, Giorgio;Moro, Lorenzo
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.230-237
    • /
    • 2021
  • Background: Noise-induced hearing loss is a well-known occupational disease that affects many fish harvesters from many fisheries worldwide, whose risk factor is prolonged exposure to hazardous noise levels. To date, academic research activities and regulatory bodies have not provided any comparative analysis among the existing methods to assess noise exposure levels of fish harvesters. This paper provides a comparison of four relevant assessment methods of noise exposure, examining the results of a measurement campaign performed onboard small fishing vessels from Newfoundland and Labrador. Methods: We traveled onboard 11 vessels engaged in multiple fisheries from Newfoundland and Labrador and performed extensive noise exposure surveys using the simplified International Maritime Organization method, the full-day measurement method, and the two methods provided by ISO 9612:2009, the task-based method and job-based method (JBM). Results: The results showed that the four methods yield similar values when the noise components are dominated by the engine and auxiliaries (steady-state sources); when noise components are dominated by the fishing gear, task-based method and the simplified International Maritime Organization method estimates are less accurate than JBM, using full-day measurements as baseline. Conclusion: The JBM better assesses noise exposure in small-scale fisheries, where noise exposure has significant variance and uncertainties on the exposure levels are higher.

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

크로스 스펙트럼 기법을 이용한 저레벨 소음의 측정 (Measurement of low level sound noise using cross spectrum method)

  • 박창규;강경일
    • 한국정보통신학회논문지
    • /
    • 제2권2호
    • /
    • pp.241-248
    • /
    • 1998
  • 실내 소음의 정확한 측정은 환경소음 관리상에 요구되어 지는 것이나 측정계 자체의 잡음으로 인하여 소음원이 가지는 원래의 잡음이 항상 영향을 받게되는 문제가 있다. 본 연구에서는 새로운 소음레벨 측정기술로서 크로스 스펙트럼법을 사용하여 측정된 신호로부터 측정계가 가지는 잡음을 효과적으로 제거하는 방법을 제안하였다. 두 개의 측정용 마이크로폰으로부터 받아들인 신호는 각각의 전치 증폭기를 통하여 A/D 변환기에 의해 디지털 신호화하여 크로스 스펙트럼을 이 디지털화 된 신호로부터 계산하고 측정계가 가지는 잡음과 소음 원의 잡음은 서로 무상관이므로 우리가 원하는 정확한 소음레벨을 측정할 수 있는 것이다. 제안된 기술의 성과는 염가의 상용 마이크로폰으로도 사용할 수 있었기 때문에 실험적으로 그 유효성과 경제성이 입증되었다.

  • PDF

외부교통소음 측정 및 평가방법에 따른 소음특성 비교 연구 (A Comparative Study on Noise Characteristics for Measuring and Evaluating Method of Exterior Traffic Noise)

  • 양재훈;김경우;최현중;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.480-483
    • /
    • 2007
  • Recently, many apartment houses were built in nearby road and railway. Road traffic noise level and railroad traffic noise level are important factors on apartment houses inhabitant's acoustic comforts. The measurement methods which noted by Ministry of Construction & Transportation, Ministry of Environment and Korean Industrial Standard are used for measurement of exterior noise at apartment houses. The purpose of this study compare the noise level characteristic by the measuring methods and evaluating methods. The results show that road traffic noise in the daytime appeared by not greatly noise level difference by the measuring method and evaluating methods. But railroad traffic noise appeared by greatly the noise level difference by the equivalent noise level(1hour) and continuous time.

  • PDF

OLE 기반 엔진 구동 부품의 자동 소음 검사 장비 개발 (The Development of an Automatic Noise Inspection System of a Rotating Engine Part Using OLE)

  • 이상철;한성복;최성배
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.968-974
    • /
    • 2004
  • Automakers have been forcing their suppliers to guarantee qualities of parts. Then, the suppliers have met the fundamental quality requirements such as dimensions and functions, but they could not sufficiently satisfy the automakers' noise requirements yet because automatic noise inspection systems were little successfully adopted In mass-production lines. This study tried to develop a system for automatically checking noise radiated from a rotating engine part and filtering parts emitting noise higher than criteria: the upper limits of a overall noise level or a noise spectrum. A commercial noise measurement system was used for measuring noise, and then the noise data was transmitted to a governing program through OLE(object, linking and embedding) functions. The governing program, belonging to a total noise inspection system managed the noise measurement and analysis. This system was successfully adapted for distinguishing bad parts according to the noise criteria.

TIME-DOMAIN TECHNIQUE FOR FRONT-END NOISE SIMULATION IN NUCLEAR SPECTROSCOPY

  • Neamintara, Hudsaleark;Mangclaviraj, Virul;Punnachaiya, Suvit
    • Nuclear Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.717-724
    • /
    • 2007
  • A measurement-based time-domain noise simulation of radiation detector-preamplifier (front-end) noise in nuclear spectroscopy is described. The time-domain noise simulation was performed by generating "noise random numbers" using Monte Carlo's inverse method. The probability of unpredictable noise was derived from the empirical cumulative distribution function via the sampled noise, which was measured from a preamplifier output. Results of the simulated noise were investigated as functions of time, frequency, and statistical domains. Noise behavior was evaluated using the signal wave-shaping function, and was compared with the actual noise. Similarities between the response characteristics of the simulated and the actual preamplifier output noises were found. The simulated noise and the computed nuclear pulse signal were also combined to generate a simulated preamplifier output signal. Such simulated output signals could be used in nuclear spectroscopy to determine energy resolution degradation from front-end noise effect.

고감도 SQUID 냉각을 위한 저잡음 듀아의 설계 및 특성 조사 (Design and Characterization of Low-noise Dewar for High-sensitivity SQUID Operation)

  • 유권규;이용호;김기웅;권혁찬;김진목
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.152-157
    • /
    • 2010
  • We have fabricated the low noise liquid helium(LHe) dewar with a different shape of thermal shield to apply the 64-channel SQUID(Superconducting Quantum Interference Device) gradiometer. The first shape of thermal shield was made of an aluminum plate with a wide width of 100 mm slit and the other shape was modified with a narrow width of 20 mm slit. The two types of dewars were estimated by comparing the thermal noise and the signal-to-noise ratio(SNR) of magnetocardiography(MCG) using the $1^{st}$ order SQUID gradiometer system cooled each dewar. The white noise was different as a point of the dewar. The noise was increased as close as the edge of dewar, and also increased at the thermal shield with the more wide width slit. The white noise of the dewar with thermal shield of 100 mm slit was 6.5 fT/$Hz^{1/2}$ at the center of dewar and 25 fT/$Hz^{1/2}$ at the edge, and the white noise of the other one was 3.5 - 7 fT/$Hz^{1/2}$. We measured the MCG using 64-channel SQUID gradiometer cooled at each LHe dewar and compared the SNR of MCG signal. The SNR was improved of 10 times at the LHe dewar with a modified thermal shield.

한국형 고속철도의 소음 전파특성에 관한 연구 (A Study on Propagation Characteristic of Noise Sources for Korea Train Express)

  • 유충준;김재철
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.224-229
    • /
    • 2004
  • In order to control the railway noise, the radiation characteristic of the noise when the train passes by should be analyzed. Generally, the major noise sources of the Korea Train Express are the rolling noise and power unit noise up to 300km/h. In this paper, a train model that is considered to be a row of point sourcesis introduced to analyze the radiation characteristic. The analysis results are compared with the measurement ones. It is shown that the propagation characteristic of the rolling noise is a dipole type and the noise generated by the power unit is radiated as a cosine type. With increasing of the train speed, the noise level at a receiving point is increased in the direction of motion and reduced in the direction opposite to the motion. The analysis results including the moving effect of the noise source at 300km/h show good agreement with the measurement results.

실내 충격소음 측정시스템 구현에 관한 연구 (A study of the measurement systems implementation for the interior impulse noise)

  • 송기혁;정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.93-100
    • /
    • 2014
  • 본 연구의 목적은170dB 이상의 고충격 소음원에서 실내 충격소음을 측정 평가 할 수 있는 측정시스템 구축 방법을 제안하는데 있다. 이러한 목적을 달성하기 위하여 실내충격소음 측정시스템용 시험장을 설계 및 구현하고, 충격소음 측정용 마이크로폰, Head & Torso Simulator, Ear Simulator를 구성하였다. 충격소음 측정 시 정확한 측정을 위하여 3가지 측정방법을 동시에 측정할 수 있도록 구현하였으며, 정확성과 신뢰성을 위하여 3가지의 실내충격소음 측정값을 상호 비교하였다. 3가지 측정방법에 따른 최대 음압레벨과 옥타브 밴드 결과를 비교 분석함으로써 실내 충격소음의 주파수 특성에 따른 차이점을 확인하였다. 이러한 결과는 반사파의 영향에 의한 것으로 판단된다. 이에, 시험장의 크기를 변형하면서 측정할 수 있도록 실내 충격소음 측정시스템을 구현하였다. 본 시스템 구현을 통하여, 충격 소음원의 특징분석과 해당 주파수별 스펙트럼의 반사파 영향들을 파악할 수 있을 것이며, 향후, 실내 충격소음에 대한 데이터 획득 및 분석을 위하여 유용하게 활용될 수 있을 것으로 판단된다.