A Comparison of Noise Level by Noise Measuring Methods (소음측정방법에 따른 평가소음도 비교)

  • Shim, Chur Goo;Roh, Jae hoon;Park, Jung Gyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol (흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교)

  • Lee, Won-Jeong;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • The purpose of this study was to compare radiation dose and image quality between low-dose (LDP) and standard-dose protocol (SDP). LDP (120 kVp, 30 mAs, 2-mm thickness) and SDP (120 kVp, 180 mAs, 1.2-mm thickness) images obtained from 61 subjects were retrospectively evaluated at level of carina bifurcation, using multi-detector CT (Brilliance 16, Philips Medical Systems). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated at ascending aorta and infraspinatus muscle, from CT number and back-ground noise. Radiation dose from two protocols measured at 5-point using acrylic-phantom, and CT number and noise measured at 4-point using water-phantom. All statistical analysis were performed using SPSS 19.0 program. LDP images showed significantly more noise and a significantly lower SNR and CNR than did SDP images at ascending aorta and infraspinatus muscle. Noise, SNR and CNR were significantly correlated with body mass index (p<0.001). Radiation dose, SNR and CNR from phantom were significant differences between two protocols. LDP showed a significant reduction of radiation dose with a significant change in SNR and CNR compared with SDP. Therefore, exposure dose on LDP in clinical applications needs resetting highly more considering image quality.

A Follow-up Study on the Personal Noise Exposed Dose and Hearing Loss (개인 소음폭로량과 청력손실에 관한 추적조사)

  • Kim, Won-Sool;Hong, Young-Seoub;Kim, Yang-Seak;Lee, Sang-Ju;Park, Kyung-Il;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.2 s.46
    • /
    • pp.286-298
    • /
    • 1994
  • For the purpose of presenting the basic data for the establishment of control measures on the long-term noise exposed workers, this study was carried out on the relationship between personal noise exposed dose and hearing loss on the 67 male workers whose hearing threshold had exceeded 40 dB in 4,000 Hz, from 1990 to 1992. Conclusively, the level of hearing loss was significantly related to personal noise exposed dose in follow-up period. We considered that personal noise exposed dose which was measured by the personal noise dosemeter was more efficient rather than the noise level of workplace for the evaluating the long-term change of hearing acuity. And although in the case of not-diagnosed as noise induced hearing loss. it was suspected that the active control programs such as improvement of noisy environment or early transfer to proper workplace were needed on the workers who exposed with over 90 dB in personal noise exposed dose.

  • PDF

Estimation of Noise Level and Edge Preservation for Computed Tomography Images: Comparisons in Iterative Reconstruction

  • Kim, Sihwan;Ahn, Chulkyun;Jeong, Woo Kyoung;Kim, Jong Hyo;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.92-98
    • /
    • 2021
  • Purpose: This study automatically discriminates homogeneous and structure edge regions on computed tomography (CT) images, and it evaluates the noise level and edge preservation ratio (EPR) according to the different types of iterative reconstruction (IR). Methods: The dataset consisted of CT scans of 10 patients reconstructed with filtered back projection (FBP), statistical IR (iDose4), and iterative model-based reconstruction (IMR). Using the 10th and 85th percentiles of the structure coherence feature, homogeneous and structure edge regions were localized. The noise level was estimated using the averages of the standard deviations for five regions of interests (ROIs), and the EPR was calculated as the ratio of standard deviations between homogeneous and structural edge regions on subtraction CT between the FBP and IR. Results: The noise levels were 20.86±1.77 Hounsfield unit (HU), 13.50±1.14 HU, and 7.70±0.46 HU for FBP, iDose4, and IMR, respectively, which indicates that iDose4 and IMR could achieve noise reductions of approximately 35.17% and 62.97%, respectively. The EPR had values of 1.14±0.48 and 1.22±0.51 for iDose4 and IMR, respectively. Conclusions: The iDose4 and IMR algorithms can effectively reduce noise levels while maintaining the anatomical structure. This study suggested automated evaluation measurements of noise levels and EPRs, which are important aspects in CT image quality with patients' cases of FBP, iDose4, and IMR. We expect that the inclusion of other important image quality indices with a greater number of patients' cases will enable the establishment of integrated platforms for monitoring both CT image quality and radiation dose.

A Study on Noise Exposure Dose and Blood Pressure in an Automobile (모 자동차 공장의 소음폭로와 혈압에 관한 연구)

  • 김성천
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.48-53
    • /
    • 1991
  • This study was carried out to investigate age, noise intensity, work period, hearing loss at frequencies, hypertension and to examine correlation of the total quantity of noise exposure(Dose) and blood pressure (Response) in the auto industry during May 1987-December 1987. To perform this study 65 workers were tested. Results of this study were as follows: 1. In frequency analysis, the CS-dip phenomenon occurred around 4000 Hz. 2. Between under of ten years group and over of ten years group, average hearing loss value was statitically significant (P < 0.05). 3. The prevalence of hypertension of 65 workers was 7.84% . 4. At 90dB(A) over and 10 years under and workers in the 20's group, the total quantity of noise exposure (Dose) and systolic blood pressure (Response) were statistically significant (P < 0.05). 5. At under 10 years of work period group, the total quantity of noise exposure(Dose) and diastolic blood pressure (Response) were statistically significant(r =0.234, P < 0.1).

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Noise and Image Quality Analysis of Brain CT Examination (두부 CT검사에서의 노이즈 및 화질분석)

  • Choi, Seok-yoon;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.279-284
    • /
    • 2019
  • The purpose of this study was to find the best protocol for balance of image quality and dose in brain CT scan. Images were acquired using dual-source CT and AAPM water phantom, noise and dose were measured, and effective dose was calculated using computer simulation program ALARA(S/W). In order to determine the ratio of image quality and dose by each protocol, FOM (figure of merits) equation with normalized DLP was presented and the result was calculated. judged that the ratio of image quality and dose was excellent when the FOM maximized. Experimental results showed that protocol No. 21(120 kVp, 10 mm, 1.5 pitch) was the best, the organ with the highest effective dose was the brain(33.61 mGy). Among organs with high radiosensitivity, the thyroid gland was 0.78 mGy and breast 0.05 mGy. In conclusion, the optimal parameters and the organ dose in the protocol were also presented from the experiment, It may be helpful to clinicians who want to know the protocol about the optimum state of image quality and dose.

A Study of the Evaluation Scale of Traffic Noise base on Sound Quality Index (음질을 기초한 교통소음의 척도화에 관한 연구)

  • Hur, Deog-Jae;Jo, Kyoung-Sook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1280-1284
    • /
    • 2006
  • This paper describes the methodology for environmental assessments of traffic noise sources. An attempt is made to establish evaluation scale relationships between noise quality Parameters and subjective degrees annoyance. Subjective experimental was conducted to determine the subjective degrees annoyance that scaling score compare with reference and varieties noise source about modified traffic noises with $40{\sim}85dB$. Also a correlation analysis between noise rating index and satisfactory percentage of the noise dose response curves varied with response was conducted. As a result of study, subjective annoyance degree has not correlation of proportional linearity to the A weight noise level, but has correlation of proportional linearity to the index composed to loudness and tonality. It is suggested to be resonable level 4.9 (equivalence about 53dB) index on the out door noise limits for traffic noise and to be 6 step scale base on the linearity for evaluation traffic noise.

  • PDF

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Noise Reduction on Low Tube Voltage CT Images (저관전압 CT영상에서 발생되는 노이즈 제거)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • To reduce the exposure dose in head CT, the use of low tube voltage is required. However, increasing noise may cause errors in the second data processing. In this study, we proposed a method to reduce noise by using low tube voltage. Experimental results show that the noise level is high at 100kVp and lowest at 140 kVp. The dose was lower at 100 kVp and higher at 140 kVp. As a result of applying the wavelet according to the threshold value, the noise value in the wavelet Th30 decreased to 4.51. Using the parameter condition(100 kVp, rotation time 0.5 sec, dose: 40.64 mGy) and the wavelet Th 30, the dose reduction of 65.3% was possible. We believe that applying the proposed method to head CT images will help to patient safety and interpret accurate information.