• 제목/요약/키워드: Noise Standard

검색결과 1,475건 처리시간 0.027초

소음지도를 이용한 도로교통소음에 관한 연구 - 시화멀티테크노밸리 개발사업을 중심으로 - (A Study on the Road Traffic Noise Effect Using a Noise Map - Development of Sihwa Multi Techno Valley -)

  • 정재훈;김흥만;권우택;김형철
    • 환경영향평가
    • /
    • 제18권2호
    • /
    • pp.89-97
    • /
    • 2009
  • Korean society is faced with various new problems arising from the development projects of new towns, industrial cities, large-scale residential complexes, etc. started from the 1970s. Particularly with the construction of residential and industrial complexes by the roadsides, they are openly exposed to road traffic noise and vibration. Thus, the objective of this study is to examine using noise maps how increasing traffic volume affects road traffic noise and what problems it causes in areas where new towns or complexes are constructed by development projects. According to the results of this study, in areas around the sites of development projects, the noise level increased by road traffic noise compared to that before development and was 1.16~6.92 times higher than the environmental noise standard, but measures to reduce road traffic noise was lukewarm. In addition, areas with soundproof facilities showed a noise level 1~3 step lower than other areas, and in individual buildings, the noise level on the side facing the road was 1~2 step higher than that on the rear side.

항공 및 도로 교통 소음권내 초등학교의 소음실태분석 (An analysis of Noise Conditions in Elementary Schools Located near Airport and Roads)

  • 최윤정
    • 대한가정학회지
    • /
    • 제43권4호
    • /
    • pp.31-47
    • /
    • 2005
  • This study is a preliminary investigation into improving the environmental quality of schools. The purpose was to clarify the present conditions and reasons of noise in elementary schools located near airports and roads by noise level measurements and questionnaire surveys of subjective responses. fold measurements on equivalent and instantaneous noise levels, indoor and outdoor, were carried out in 3 schools during the periods 11th~ 13th of February and 2nd~ 7th of July,2003. The respondents were 94 teachers working in the 3 schools. The results were as follows. 1) Indoor noise levels of the 3 schools were 36.g~73 dB(A) in winter, and 46.9~ 91 dB(A) in summer. These values were higher than the indoor noise standard of 50 dB(A), except for the average of equivalent noise levels in winter.2) Outdoor noise levels of the schools were 41.1 ~ 101 dB(A) in winter, and 52.4~ 102 dB(A) in summer. These values were generally inappropriate relative to the standard for environmental noise of 65 dB(A). 3) The respondents showed relatively non- positive responses during school hours for interruptions by environmental noise.4) The frequently checked types of environmental noise of the schools were 'airplane noise','surrounding facilities', and 'traffic noise'. The frequently checked types of damage by environmental noise were 'Interrupting school hours' and 'Interrupting business'.

Noise Reduction Using the Standard Deviation of the Time-Frequency Bin and Modified Gain Function for Speech Enhancement in Stationary and Nonstationary Noisy Environments

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • The Journal of the Acoustical Society of Korea
    • /
    • 제26권3E호
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper we propose a new noise reduction algorithm for stationary and nonstationary noisy environments. Our algorithm classifies the speech and noise signal contributions in time-frequency bins, and is not based on a spectral algorithm or a minimum statistics approach. It relies on calculating the ratio of the standard deviation of the noisy power spectrum in time-frequency bins to its normalized time-frequency average. We show that good quality can be achieved for enhancement speech signal by choosing appropriate values for ${\delta}_t\;and\;{\delta}_f$. The proposed method greatly reduces the noise while providing enhanced speech with lower residual noise and somewhat higher mean opinion score (MOS), background intrusiveness (BAK) and signal distortion (SIG) scores than conventional methods.

학교부지의 방음벽 설계를 위한 소음지도 해석 (Noise Map Analysis for the Design of Noise Barrier at School Site)

  • 윤준호;김원진
    • 대한환경공학회지
    • /
    • 제34권4호
    • /
    • pp.232-238
    • /
    • 2012
  • 소음지도 모의시험을 이용하여 학교부지의 소음저감을 위한 방음벽 설계에 대한 연구를 수행하였다. 해석모델은 학교부지의 지형적 특성에 따른 감쇠와 소음전파 경로상의 건축물에 의한 회절 감쇠 효과를 고려하여 모델링하고, 주요 소음원인 고속도로의 음향파워레벨은 학교부지의 지점에서 측정한 소음도를 기준으로 평가하였다. 방음벽 효과분석을 위한 소음지도 모의시험은 ISO 9613 규격을 기반으로 하는 환경소음 예측프로그램 ENPro를 이용하여 수행하였다. 모의시험의 결과로부터 소음환경기준을 만족하는 방음대책을 수립하고, 비용과 안전을 고려한 방음벽을 설계하였다.

Direction Information Concerned Algorithm for Removing Gaussian Noise in Images

  • Gao, Yinyu;Kim, Nam-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제9권6호
    • /
    • pp.758-762
    • /
    • 2011
  • In this paper an efficient algorithm is proposed to remove additive white Gaussian noise(AWGN) with edge preservation. A function is used to separate the filtering mask to two sets according to the direction information. Then, we calculate the mean and standard deviation of the pixels in each set. In order to preserve the details, we also compare standard deviations between the two sets to find out smaller one. Corrupted pixel is replaced by the mean of the filtering window's median value and the smaller set's mean value that the rate of change is faster than the other one. Experiment results show that the proposed algorithm outperforms with significant improvement in image quality than the conventional algorithms. The proposed method removes the Gaussian noise very effectively.

표준실험동에서 중량충격음의 방사 특성 (Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building)

  • 유승엽;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

표준실험동의 구조별 소음 진동 특성 (Noise and Vibration Characteristics of Construction structures in Standard Laboratory)

  • 정영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.390-393
    • /
    • 2005
  • In this study, examined heavy-weight floor impact sound to rahmen structure(steel reinforced concrete structure) and bearing-wall structure(box frame type structure) that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results of ANSYS modeling of structures was predicted that the nature natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Rahmen structures compares with bearing-wall structure, nature frequency was predicted low. Measurement results of natural frequency and acceleration level for structures at a standard laboratory, tendency department such as ANSYS modeling appeared. Rahmen structures appeared that reduction effect is less in Acceleration level and heavy impact sound transmission level comparing with bearing-wall structure.

  • PDF

슬래브 두께에 따른 표준실험동의 중량충격음 특성 (Heavy-weight Floor Impact Sound Characteristics of Standard Laboratory by Slab Thickness)

  • 정영;송희수;전진용;김진수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.103-108
    • /
    • 2004
  • In this study, examined heavy-weight floor impact sound to structure that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results show that the nature Natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Results of measurements of noise and vibration at a standard laboratory, the slab 210, 240mm structures was construed result such as finite element analysis but the slab 150, 180mm structures is construed that influence in vibration acceleration level because edge condition has condition that contact to ground. Therefore, in modelling process for analysis, is thought that need that condition analyzes examining element influencing about structure that contact to ground.

  • PDF

EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발 (The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form)

  • 박철용;김상훈;장동운;장철호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구 (An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom)

  • 이태강;송민정;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF