• Title/Summary/Keyword: Noise Standard

Search Result 1,472, Processing Time 0.023 seconds

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

Usefulness of Deep Learning Image Reconstruction in Pediatric Chest CT (소아 흉부 CT 검사 시 딥러닝 영상 재구성의 유용성)

  • Do-Hun Kim;Hyo-Yeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • Pediatric Computed Tomography (CT) examinations can often result in exam failures or the need for frequent retests due to the difficulty of cooperation from young patients. Deep Learning Image Reconstruction (DLIR) methods offer the potential to obtain diagnostically valuable images while reducing the retest rate in CT examinations of pediatric patients with high radiation sensitivity. In this study, we investigated the possibility of applying DLIR to reduce artifacts caused by respiration or motion and obtain clinically useful images in pediatric chest CT examinations. Retrospective analysis was conducted on chest CT examination data of 43 children under the age of 7 from P Hospital in Gyeongsangnam-do. The images reconstructed using Filtered Back Projection (FBP), Adaptive Statistical Iterative Reconstruction (ASIR-50), and the deep learning algorithm TrueFidelity-Middle (TF-M) were compared. Regions of interest (ROI) were drawn on the right ascending aorta (AA) and back muscle (BM) in contrast-enhanced chest images, and noise (standard deviation, SD) was measured using Hounsfield units (HU) in each image. Statistical analysis was performed using SPSS (ver. 22.0), analyzing the mean values of the three measurements with one-way analysis of variance (ANOVA). The results showed that the SD values for AA were FBP=25.65±3.75, ASIR-50=19.08±3.93, and TF-M=17.05±4.45 (F=66.72, p=0.00), while the SD values for BM were FBP=26.64±3.81, ASIR-50=19.19±3.37, and TF-M=19.87±4.25 (F=49.54, p=0.00). Post-hoc tests revealed significant differences among the three groups. DLIR using TF-M demonstrated significantly lower noise values compared to conventional reconstruction methods. Therefore, the application of the deep learning algorithm TrueFidelity-Middle (TF-M) is expected to be clinically valuable in pediatric chest CT examinations by reducing the degradation of image quality caused by respiration or motion.

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

The Study on Risk Factors Analysis and Improvement of VDT Syndrome in Nuclear Medicine (핵의학과 Video Display Terminals Syndrome 유해 요인 조사 및 개선에 관한 연구)

  • Kim, Jung-Soo;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo;Han, In-Im;Joo, Yung-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: Recently, Department of Nuclear Medicine have an interest in Video Display Terminals (VDT) syndrome including musculoskeletal disorders, ophthalmologic disorders, trouble of electromagnetic waves and stress disorders occur to VDT workers as the growing number of users and rapid pace of service period supply in large amount. This study research on the actual condition for VDT syndrome in Nuclear Medicine, Seoul National University Hospital (SNUH), discover the problem and draw a plan of upcoming improvement. The aim of this study establish awareness about VDT syndrome and is to prevent for it in the long run. Materials and Methods: Department of Nuclear Medicine, SNUH is composed Principle part, Pediatric part and PET center. We estimated risk factors visit in each part directly. Estimation method use "Check list for VDT work" of Wonjin working environment health laboratory and check list is condition of VDT work, condition of work tables, condition of chairs, condition of keyboards, condition of monitors, working position, character of health management and other working environment. Analysis result is verified in Department of Occupational and Environment, Hallym University Sacred Heard Hospital. Results: As a result of analysis, VDT condition of Department of Nuclear Medicine, SNUH is rule good. In case of work tables, recent of things are suitable to users upon the ergonomical planning, but 15% of existing work tables are below the standard value. In case of chairs are suitable, but 5% of theirs lost optimum capacity become superannuated. The keyboards are suitable for 98% of standard value. In case of monitors, angle control of screen is possible of all, but positioning control is impossible for 38%. In case of working position, 10% is fixed positioning for long time and some of the items researched unsuitable things for standard. At health management point, needed capable of improvement. Also, other working condition as lighting, temperature, noise and ventilation, discovered the problem, but is sufficient to advice value. Conclusion: VDT syndrome is occurrences of possibility continuously, come economical expensive about improvement, is inherent in various causes and originate without your knowledge. So, there is need systematic management system. In Nuclear Medicine, VDT syndrome make it better that constant interest and effort as improvement of ergonomical working environment, improvement of working procedure, regular exercise and steady stretching, and can be prevented fairly. This promote physical and mental condition of worker in top form in comfortable working environment, so this is judged by enlargement of operations efficiency and rising of satisfaction ratings of the inside client.

  • PDF

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Status of Industrial Environments of Some Industries in Taegu Kyungpook Area (대구지방 산업장에 있어서 건강장애요인과 작업환경검사에 대한 기업인의 수용태도 (ll))

  • Kim, Du-Hui;Seong, Su-Won
    • 월간산업보건
    • /
    • s.8
    • /
    • pp.4-30
    • /
    • 1988
  • Examination of working environments was conducted to get more detailed data about harmful working environments and to make a contribution to more effective management. Study was carried out on 722 factories located in Taegu city and eight counties in Kyungpook Province, Korea, for a period of one year, from February 1 to December 30, 1986. The total number and proportion of workers exposed to harmful material was 37,697, 45.2% among 83,368 workers. The results according to exposed material were as follows: 1. In the case of noise, proportion of exceeding the 8-hour TLV was 59%, Included were nail-cutting in assembly metal manufacturing industry and weaving process in textile. 2. Dust in mill process of coal manufacturing industries exceeded the TLV of second class of dust at all parts and exceeded the TLV at 6% as a whole.: 3. The fields of industry lower than 70 lux of illumination were storage equipment of food, auto-winder of textile, painting of wood wares and coal mixing, and 44% of all cases was lower than standard. 4. As a result of temperature index investigation(WBGT), about 12% of all sujects exceeded limit value. Included parts were rolling machine and reducing room. 5. In the case of organic solvents, TLV was exceeded at about 8%, The parts exceeded TLV according to materials belonged to this category were as follows. 1) Toluene: adhesive work in assembly metal manufacturing 2) Xylene: printing and paint mixing in chemical manufacturing 3) Methyl ethytl ketone: paint mixing in all parts examined and coating machine partially in chemical manufacturing 4) Methyl isobutyl ketone: printing in chemical manufacturing 5) Acetone: vapor polishing in assembly metal manufacturing 6. Among specified chemical materials, the concentration of HC1 in the air in metal assembly manufacturing factory exceeded TLV. in one of three assembly metal manufacturing examined. Others, such as benzene, acetic acid, formic acid, sodium hydroxide, formalin, ammonia, copper, chromate etc. were lower than TLV in its indoor atmospheric concentration. As a whole, the proportion of exceeding TLV was about 0.8% 7. The concentrations of inorganic lead were lower than TLV in all parts examined. The results of this investigation show the fact that current management of working environments is not satisfactory, and so more active management is needed.

  • PDF

A 3.125Gb/s/ch Low-Power CMOS Transceiver with an LVDS Driver (LVDS 구동 회로를 이용한 3.125Gb/s/ch 저전력 CMOS 송수신기)

  • Ahn, Hee-Sun;Park, Won-Ki;Lee, Sung-Chul;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.7-13
    • /
    • 2009
  • This paper presents a multi-channel transceiver that achieves a data rate of 3.125Gb/s/ch. The LVDS is used because of its noise immunity and low power consumption. And a pre-emphasis circuit is also proposed to increase the transmitter speed. On the receiver side, a low-power CDR(clock and data recovery) using 1/4-rate clock based on dual-interpolator is proposed. The CDR generates needed additional clocks in each recovery part internally using only inverters. Therefore each part can be supplied with the same number of 1/4-rate clocks from a clock generator as in 1/2-rate clock method. Thus, the reduction of a clock frequency relaxes the speed limitation and lowers power dissipation. The prototype chip is comprised of two channels and was fabricated in a $0.18{\mu}m$ standard CMOS process. The output jitter of transmitter is loops, peak-to-peak(0.31UI) and the measured recovered clock jitter is 47.33ps, peak-to-peak which is equivalent to 3.7% of a clock period. The area of the chip is $3.5mm^2$ and the power consumption is about 119mW/ch.