• Title/Summary/Keyword: Noise Floor

Search Result 659, Processing Time 0.033 seconds

Effect of spatial factors on subjective responses to heavy-weight floor impact noise (중량충격음의 주관적 반응에 대한 공간음향요소의 영향)

  • Lee, Pyoung-Jik;Kim, Jae-Ho;Yoo, Seung-Yup;Sato, Shin-Ichi;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.960-963
    • /
    • 2007
  • The effect of spatial factors on subjective responses to heavy-weight floor impact noise was investigated. Heavy-weight impact noises were generated and recorded in several apartments and a testing building using impact ball and binaural microphone to measure IACC of the noises. Just noticeable differences (JNDs) of IACC and SPL of heavy-weight impact noise were also investigated. Auditory experiments were conducted using method of limit. It was found that the JNDs of IACC and SPL were 0.12 and 1.5dB, respectively. Contribution of IACC and SPL to annoyance of heavy-weight floor impact noise is being further investigated.

  • PDF

Evaluation of Floor Impact Sound Isolation in a Dry Floor System (건식 바닥구조의 바닥충격음 차단성능 평가)

  • You, Jin;Ryu, Jong-Kwan;Jeon, Jin-Young;Lee, Chung-Hwa;Kim, Chul-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.950-953
    • /
    • 2005
  • Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.

  • PDF

Use of Damping Materials for Reducing Heavyweight Floor Impact Noise in Apartment Buildings (공동주택의 중량충격음 저감을 위한 제진재의 활용)

  • Jeong, Young;Yoo, Seung-Yup;Kim, Min-Bae;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.96-99
    • /
    • 2005
  • Noise and vibration generated by heavy-weight floor impact in apartment buildings were studied. The resonance frequency increased in the floor structures where damping materials were used in the living room and the bedroom. Both the acceleration wavelength and the acceleration level decreased. The results showed that the resonance frequency increased and vibration acceleration level decreased when the damping materials were used. Heavy-weight impact sound levels of the structure decreased substantially below 80Hz.

  • PDF

A Effects of applying the noise reduction method between existing buildings (기존 건축물 층간소음 저감공법 적용 효과 분석)

  • Song, Tae-Hyeob;Jeon, Chan-Soo;Kim, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.249-250
    • /
    • 2018
  • To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

  • PDF

A Study on the Floor Impact Noise Analysis (바닥충격음 해석에 관한 연구)

  • Kim Hyun-Sil;Kim Jae-Seung;Kang Hyun-Joo;Kim Bong-Ki;Kim Sang-Ryul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.461-468
    • /
    • 2002
  • Prediction method of floor impact noise for light and heavy weight impact is described. Sound pressure level is predicted based on the impedance method. For floating floor system, noise reduction is studied assuming 1-D mass-spring system. It is found that comparisons of predictions and measurements show good agreements. However, certain correction factor is needed to predict noise reduction of floating floor system.

  • PDF

Heavy-weight Floor Impact Sound Characteristics of Standard Laboratory by Slab Thickness (슬래브 두께에 따른 표준실험동의 중량충격음 특성)

  • Jeong, Young;Song, Hee-Soo;Jeon, Jin-Yong;Kim, Jin-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.103-108
    • /
    • 2004
  • In this study, examined heavy-weight floor impact sound to structure that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results show that the nature Natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Results of measurements of noise and vibration at a standard laboratory, the slab 210, 240mm structures was construed result such as finite element analysis but the slab 150, 180mm structures is construed that influence in vibration acceleration level because edge condition has condition that contact to ground. Therefore, in modelling process for analysis, is thought that need that condition analyzes examining element influencing about structure that contact to ground.

  • PDF

Research about correlation of slab vibration mode and heavy-weight floor impact sound (슬래브의 동특성과 중량충격음의 상관관계에 관한 연구)

  • Chung, J.Y.;Lee, S.W.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

Analysis of Correlation between the Vibration Transmissions and the Dynamic Characteristics for Floor Impact Sound Insulation Materials through Model Test (모의실험을 통한 완충재별 진동전달량과 동적특성과의 상관성 분석에 관한 연구)

  • Kim, Heung-Sik;Joo, Si-Woong;Jin, Pil-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1425-1431
    • /
    • 2006
  • In this study, An analysis of correlation between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials through model test was carried out. As the results, the correlation coefficients between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials were over 0.8 at the heavy and light floor impact source and less dynamic stiffness was more effective in reducing the vibration transmission.

  • PDF

An Experimental Study on the Reduction of Floor Impact Sound in Apartment Houses by using Model Test (모델 실험체를 이용한 공동주택 바닥충격음 저감에 관한 실험적 연구)

  • Kim, Hang;Gi, No-Gab;Park, Hyeon-Ku;Song, Min-Jeong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1044-1047
    • /
    • 2004
  • This aim of this study is is an experimental study to introduce the Reduction method of Floor Impact Sound in Apartment Houses by using Model Test, We are measured the floor impact sound in Rahamen and Apartment with Shear Wall and Post-tensioning. There is comparison between Rahmen Structure and Apartment with Shear Wall. The main results from this study are effective in reduction of heavt-weight The slab was constructed by rahamen structure. Heavy-weight can reduced by upgrading naturial frequency of floor impact sound in rahmen structure.

  • PDF

Assessment of Vibration Transmissibility for Prediction of Heavy Floor Impact Sound (중량 바닥충격음 예측을 위한 진동 전달률 산정 연구)

  • 김하근;김명준;오양기
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.415-422
    • /
    • 2003
  • In an apartment buildings, the floor Impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation, it is necessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to suggest the supplementary formula(equation) and constant k considering vibration transmissibility in order to predict more precisely heavy floor impact sound by Impedance Method that have been briskly studied in Japan from comparing the measured values with the predicted values. The analyzed results had showed that if the damping material was glass wool or rubber, k=5 was proper and if the damping material was polystyrene foam, k>5 was desirable.