Evaluation of Floor Impact Sound Isolation in a Dry Floor System

건식 바닥구조의 바닥충격음 차단성능 평가

  • 유진 (한양대학교 대학원 건축공학과) ;
  • 류종관 (한양대학교 대학원 건축공학과) ;
  • 전진용 (한양대학교 건축공학부) ;
  • 이충화 (LG화학 산업재연구소) ;
  • 김철환 (LG화학 산업재연구소)
  • Published : 2005.11.01

Abstract

Floor impact sounds from two different floor systems were measured. One of the two floor systems is a dry floor system (with 150mm concrete slab) and the other is a standard floor system (210mm concrete slab). Real impact sources such as jumping and running of children were used as well as standard impact sources (bang machine, impact ball and tapping machine) to evaluate sound Isolation of the two floor systems. Subjective evaluations of the floor impact sound isolation performance for the two systems were also conducted by the methods of 3 scales & 9 categories, paired comparison and semantic differentials. Measurement results indicate that floor impact sound isolation performance of the dry floor was better than that of standard floor in both cases of real and standard impact sources. The subjects in auditory experiments also evaluated the dry floor as a better sound isolation system.