• Title/Summary/Keyword: Noise Cut-off

Search Result 113, Processing Time 0.021 seconds

A Study on the FIR Digital Filter using Modified Window Function (변형된 창함수를 사용한 FIR 디지털 필터에 관한 연구)

  • 강경덕;배상범;김남호;류지구
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.1
    • /
    • pp.49-55
    • /
    • 2003
  • The use of digital filters in the signal process field is increasing rapidly with development of the modern industrial society. Especially, detail processors, Y/C separators, ghost removing filters, standard converters (NTSC to PAL or PAL to NTSC) and noise reducers, all of which use digital filters, tend to be used in digital video and audio processing, CATV and various communication fields. Generally, there are two different digital filters, the Rf (infinite impulse response) filter and the FIR (finite impulse response) filter in digital filter. In this paper, we have designed FIR filter which has the phase linearity and the easiness of creation. In the design of the FIR digital filter, the window function is used to alleviate the ripples caused by Gibbs Phenomenon around the cut off frequency of the band pass. But there're some problems to choose proper window function for the design destination due to its fixed values. Therefore, in this paper, we designed a modified Hanning window with new parameter which is adaptively chosen corresponding to design objectives. The digital filter was simulated to prove the validity of the model and it was compared with the Hamming, the Manning, the Blacknan and the Kaiser window function. And we have used peak side-lobe and transient characteristics as standard of judgement.

  • PDF

Development of a High-Performance Bipolar EEG Amplifier for CSA System (CSA 시스템을 위한 양극 뇌파증폭기의 개발)

  • 유선국;김창현;김선호;김동준
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • When we want to observe and record a patient's EEG in an operating room, the operation of electrosurgical unit(ESU) causes undesirable artifacts with high frequency and high voltage. These artifacts make the amplifiers of the conventional EEG system saturated and prevent the system from measuring the EEG signal. This paper describes a high-performance bipolar EEG amplifier for a CSA (compressed spectral array ) system with reduced ESU artifacts. The designed EEG amplifier uses a balanced filter to reduce the ESU artifacts, and isolates the power supply and the signal source of the preamplifier from the ground to cut off the current from the ESU to the amplifier ground. To cancel the common mode noise in high frequency, a high CMRR(common mode rejection ratio) diffferential amplifier is used. Since the developed bipolar EEG amplifier shows high gain, low noise, high CMRR, high input impedance, and low thermal drift, it is possible to observe and record more clean EEG signals in spite of ESU operation. Therefore the amplifier may be applicable to a high-fidelity CSA system.

  • PDF

Heuristics for Selecting Nodes on Cable TV Network (케이블 TV 망에서 노드 선택을 위한 휴리스틱 연구)

  • Chong, Kyun-Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.133-140
    • /
    • 2008
  • The cable TV network has delivered downward broadcasting signals from distribution centers to subscribers. Since the traditional coaxial cable has been upgraded by the Hybrid Fiber Coaxial(HFC) cable, the upward channels has expanded broadband services such as Internet. This upward channel is vulnerable to ingress noises. When the noises from the children nodes accumulated in an amplifier exceeds a certain level, that node has to be cut off to prevent the noise propagation. The node selection problem(NSP) is defined to select nodes so that the noise in each node does not exceed the given threshold value and the sum of Profits of selected nodes can be maximized. The NSP has shown to be NP-hard. In this paper, we have proposed heuristics to find the near-optimal solution for NSP. The experimental results show that interval partitioning is better than greedy approach. Our heuristics can be used by the HFC network management system to provide privileged services to the premium subscribers on HFC networks.

  • PDF

EBG Structure Using Bridge Line in the Signal Transmission Plane (신호 전달 평면의 브릿지 라인을 이용한 EBG 구조)

  • Kim, Byung-Ki;Ha, Jung-Rae;Lee, June-Sang;Bae, Hyeon-Ju;Kwon, Jong-Hwa;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.786-795
    • /
    • 2010
  • In this paper, we propose a new EBG structure that the two unit cells are connected by the bridge line in signal transmission plane. The SSN of the power plane is reduced effectively by via holes and bridge lines connecting the unit cells. The superior signal transfer characteristic is shown between the signal lines in the signal transmission plane. The proposed EBG structure contains 1.2 GHz cut-off frequency and less than -30 dB suppression in the 8.3 GHz broad bandwidth. In addition, To improve the SI(Signal Integrity) in signal transmission plane keeping the same bandstop frequency range, the optimized location of the reference plane is proposed.

A Design Of Cross-Shpaed CMOS Hall Plate And Offset, 1/f Noise Cancelation Technique Based Hall Sensor Signal Process System (십자형 CMOS 홀 플레이트 및 오프셋, 1/f 잡음 제거 기술 기반 자기센서 신호처리시스템 설계)

  • Hur, Yong-Ki;Jung, Won-Jae;Lee, Ji-Hun;Nam, Kyu-Hyun;Yoo, Dong-Gyun;Yoon, Sang-Gu;Min, Chang-Gi;Park, Jun-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.152-159
    • /
    • 2016
  • This paper describes an offset and 1/f noise cancellation technique based hall sensor signal processor. The hall sensor outputs a hall voltage from the input magnetic field, which direction is orthogonal to hall plate. The two major elements to complete the hall sensor operation are: the one is a hall sensor to generate hall voltage from input magentic field, and the other one is a hall signal process system to cancel the offset and 1/f noise of hall signal. The proposed hall sensor splits the hall signal and unwanted signals(i.e. offset and 1/f noise) using a spinning current biasing technique and chopper stabilizer. The hall signal converted to 100 kHz and unwanted signals stay around DC frequency pass through chopper stabilizer. The unwanted signals are bloked by highpass filter which, 60 kHz cut off freqyency. Therefore only pure hall signal is enter the ADC(analog to dogital converter) for digitalize. The hall signal and unwanted signal at the output of an amplifer and highpass filter, which increase the power level of hall signal and cancel the unwanted signals are -53.9 dBm @ 100 kHz and -101.3 dBm @ 10 kHz. The ADC output of hall sensor signal process system has -5.0 dBm hall signal at 100 kHz frequency and -55.0 dBm unwanted signals at 10 kHz frequency.

Studies on the High-gain Low Noise Amplifier for 60 GHz Wireless Local Area Network (60 GHz 무선 LAN의 응용을 위한 고이득 저잡음 증폭기에 관한 연구)

  • 조창식;안단;이성대;백태종;진진만;최석규;김삼동;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.21-27
    • /
    • 2004
  • In this paper, millimeter-wave monolithic integrated circuit(MIMIC) low noise amplifier(LNA) for V-band, which is applicable to 60 GHz wireless local area network(WLAN), was fabricated using the high performance 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate pseudomorphic high electron mobility transistor(PHEMT). The DC characteristics of PHEMT are drain saturation current density(Idss) of 450 mA/mm and maximum transconductance(gm, max) of 363.6 mS/mm. The RF characteristics were obtained the current gain cut-off frequency(fT) of 113 GHz and the maximum oscillation frequency(fmax) of 180 GHz. V-band MIMIC LNA was designed using active and passive device library, which is composed of 0.1 ${\mu}{\textrm}{m}$ $\Gamma$-gate PHEMT and coplanar waveguide(CPW) technology. The designed V-band MIMIC LNA was fabricated using integrated unit processes of active and passive device. The measured results of V-band MIMIC LNA are shown S21 gain of 21.3 dB, S11 of -10.6 dB at 60 GHz and S22 of -29.7 dB at 62.5 GHz. The measured result of V-band MIMIC LNA was shown noise figure (NF) of 4.23 dB at 60 GHz.

Design and Fabrication of Clock Recovery Module for Gap Filter of Satellite DMB (위성 DMB 중계기용 클럭 재생 모듈 설계 및 제작)

  • Hong, Soon-Young;Shin, Yeoung-Seop;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.423-429
    • /
    • 2007
  • The clock recovery module of gap filler for satellite DMB is proposed. Proposed module sustains the output frequency of 10 MHz whether the received signal from the satellite is unstable or cut off within 0.5 sec. The advantages of this module is without frequency tuning at regular interval and low material cost. This module is fabricated by using CPLD as clock recovery IC and new type of loop filter for satisfying the fast lock time and long hold over time simultaneously. The measured performance of the fabricated module has a holdover time of 11 sec at frequency stability less than 0.01 ppm, and phase noise of -113 dBc/Hz at 100 Hz offset.

Accurate Step-Count Detection based on Recognition of Smartphone Hold Position (스마트폰의 소지위치 인지 기반의 정확한 보행수 검출 기법)

  • Hur, Taeho;Yeom, Haneul;Lee, Sungyoung
    • Journal of KIISE
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2017
  • As the walking exercise is emphasized in personalized healthcare, numerous services demand walking information. Along with the propagation of smartphones nowadays, many step-counter applications have been released. But these applications are error-prone to abnormal movements such as simple shaking or vibrations; also, different step counts are shown when the phone is positioned in different locations of the body. In this paper, the proposed method accurately counts the steps regardless of the smartphone position by using an accelerometer and a proximity sensor. A threshold is set on each of the six positions to minimize the error of undetection and over-detection, and the cut-off section is set to eliminate any noise. The test results show that the six position type were successfully identified, and through a comparison experiment with the existing application, the proposed technique was verified as superior in terms of accuracy.

Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges (코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석)

  • Jo, Hyang-Eun;Jin, Chang-Hwan;Park, Dae-Won;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

Development of an Axially Viewed Inductively Coupled Plasma for Atomic Emission Spectrometry and Comparison between the Detection Limits of Lead (원자방출 분광분석을 위한 수평형 유도결합 플라스마의 개발과 납 검출한계 비교)

  • Cho, Sung Il;Han, Myung Sub;Lee, Sang Hwa;Lee, Joung Hae;Woo, Jin Chun
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.6
    • /
    • pp.292-298
    • /
    • 1997
  • An ICP(Inductively Coupled Plasma) emission spectrometer was developed with an axially viewed ICP source incorporated by a 5-turned induction coil and a torch, outer quartz tube of which was 50 mm longer than that used in conventional ICP/AES(Inductively Coupled Plasma Atomic Emission Spectrometry). The Optimization of the system has been performed in terms of the determination of signal-to-noise ratio and background intensity at various rf powers, sample flow rates, argon gas flow rates and cut-off gas flow rates. The spectro-analytical characteristics of the spectrum obtained between 200 and 500 nm was revealed to be similar compared with a vertically viewed ICP source. The detection limit of Pb(Ⅱ) at 220.35 nm was 11 ppb which was 5 times lower than that obtained with a vertically viewed ICP source.

  • PDF