• Title/Summary/Keyword: Nickel release

Search Result 20, Processing Time 0.024 seconds

Evaluation of a metal level in non-precious metal alloys dental casting having beryllium by lactic acid Solution (베릴륨함유 치과 주조용 비귀금속 합금의 젖산용액에 의한 금속 노출수준 평가)

  • Park, Soo-Chul;Jang, Eun-Jin;Han, Sok-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • Purpose: The purpose of this study is to investigate the level of each metal in non-precious metal alloys dental casting, still used even banned for use and trade by the law, for oral health. Methods: Two kinds of metal alloys were analyzed. One was Ticonium 100 for removable prosthesis and the other was Rexillium V for dental porcelain. Two samples of each metal alloy were made in 0.5g, 1.0g, and 1.5g. Total number of samples were 12. Two kinds of lactic acid Solution, pH7 and pH4.6, were injected into each samples. After injection, each samples had been for 21days ${\pm}$ 1 hour in the water tank of which temperature was $37^{\circ}C$. The level of metal was measured in each sample by inductively couplled plasma-atomic emission spectrometer. Results: In both metal alloys, metals, chrome, nickel, beryllium, and molybdenum, were founded. In Ticonium 1000, the highest level of nickel was 2.531ppm in 1.5g pH4.6 sample while the highest level of nickel was 4.062ppm in 1.5g pH4.6 sample of Rexillium V. In chemical composition of these methal alloys, chrome(14~17%) was much more than beryllium(1.95~1.99%) and molybdenum(5.0~9.0%) but berllium and molybdenum were founded more than chrome in samples. Therefore, chrome showed better anti-corrosion than other metal alloys. In both metal alloys, more metals were founded in higher pH level and more mass. Levels of chrome was significantly different in samples of both metal alloys in each pH level(p<0.05). Levels of nickels was significantly different in samples of both metal alloys in each pH level(p<0.05). Conclusion: For oral health, further studies are needed in nickel-chrome metal alloy and cobalt metal alloy of non-beryllium in addittion to beryllium metal alloy and also long-term studies needed in various period and other non-percious metal alloys for dental casting.

Applicability Test of Various Stabilizers for Heavy Metals Contaminated Soil from Smelter Area (제련소 주변 오염토양의 중금속 안정화를 위한 다양한 안정화제의 적용성 연구)

  • Jeon, Jonwon;Bae, Bumhan;Kim, Younghun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.63-75
    • /
    • 2010
  • There are several remediation technologies for heavy metal contaminated soils but increasing cost limits the application of the technology if the contaminated area is large. Therefore, stabilization, which blocks the release of heavy metals or makes slow the release, is one of the applicable technology for the heavy metal contaminated soil. Current study is an applicability test for a smelter area with various stabilizer such as magnetite, hematite, zeolite-A, zeolite-X, zeolite-Y, zinc oxide, calcium oxide, carbon trioxide, manganese oxide, manganese dioxide, fish bone, sodium phosphate. The soil contaminated with arsenic, lead, copper, nickel, and zinc could not be stabilized only one stabilizer which is known to have stability for certain metal. Many of the stabilizer works for a few metal but not all of the heavy metal. In several cases, stabilizers increase the release of the other metals while they stabilize some metals. In general, the stabilizing efficiency was increased with time. For Ni, Pb, calcium oxide, carbon trioxide, manganese oxide had good stabilizing effect in water extractable portion. For Cu, manganese oxide, zeolite showed good results especially in the exchangeable portion of the sequential extraction. For As, magnetite had good ability but most of the metal oxide which showed good result for other heavy metals increased with the release of As. Current study suggest that multiple stabilizers are needed for the contaminated soil and dose of the stabilizer and stabilizing time should be carefully considered for the soil contaminated with various metals.

Preliminary Status Analysis Methodology on Hazardous and Valuable Metal Recovery in Industrial Wastes Using Public Database (공공 자료를 활용한 산업폐기물내 유해성 유가금속 회수관련 초기 현황조사 방안)

  • Lee, Sang-hun
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.48-54
    • /
    • 2020
  • Korea, one of the manufacturing-oriented countries, consumes a large amount of metals in various industrial areas, but should depend on import of most of the metals from foreign countries. Also, global metal consumption amounts are increasing in relation to those of the world's reserve and production. Some metals are limitedly produced from only several centuries, which might lead to instability of the future supply of those metals. In addition, when such metals are hazardous, those may result in various environmental troubles with contamination. To resolve those issues, the recovery and the recycling of hazardous but valuable metals in industrial waste are desirable. However, there are overwhelming numbers of the metal types, waste generators, and amounts of wastes containing the metals, so it can be troublesome even to implement a preliminary status analysis to screen proper metals, wastes with the metals, and waste producers. Therefore, this study introduces the valuable metals for Korean industry, announced by public institutions, Also, a flow chart is suggested to facilitate a preliminary status analysis, using the domestic PRTR (Pollutant Release and Transfer Register) database, to screen proper waste producers containing some of hazardous but valuable metals such as nickel, cobalt, and manganese.

Kinetic and Equilibrium Studies on Complex Formation Between Ni(II) and D-Penicillamine in Aqueous Media (Ni(II)와 D-Penicillamine과의 착물형성반응에 대한 속도론적 및 평형에 관한 연구)

  • Yong-Kyu Kim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.475-482
    • /
    • 1986
  • Rates and equilibriurn of complex formation between $Ni^{2+}$ and D-penicillamine have been investigated in aqueous solutions. Kinetic study on the complex formation were performed in the pH range of 8∼9 by the use of pressure-jump technique. D-Penicillamine coordinates to the nickel(II) ion utilizing sulfur and nitrogen as donor atoms in the high pH condition (pH 9.2). However, in the pH range of 8.25∼9.07, the stepwise stability constant becomes drastically reduced and the undissociated mercapto group does not participate in bonding. The rate-determining step of the complexation reaction is found to be the release of a water molecule from the inner-coordination sphere of $Ni^{2+}$ ion.

  • PDF

Evaluation of cytotoxicity of electroplated stainless steel orthodontic wire (전기도금한 교정용 스테인레스스틸 선재의 세포독성에 관한 연구)

  • Lee, Gye-Hyeong;Cho, Jin-Hyoung;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.127-136
    • /
    • 2005
  • The purpose of this study was to examine the cytotoxicity of orthodontic wire which had an increased diameter through electroplating, and to evaluate its possible clinical applications, First. nickel plating was carried out on the commercially available stainless steel wire using an electroplating technique For the comparison of the electroplated wire with ready made stainless steel wire and titanium or copper. each wire was incubated for 72 hours in a medium. The release of the metal ion was measured using ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrophotometer). Balb/c 3T3 mouse fibroblast was put on a microplate and placed in an incubated medium of 75%, 50%, and 20% dilation. An MTT analysis was used to compare with the medium only. The change in absorbency value of each wire group and the difference of absorbency value according to the change of dilution was measured The results of ICP-AES analysis showed that great amount nickel iou was isolated from electroplated orthodontic wires and great amount copper ion was isolated from copper. The results of the MTT analysis showed that there was no difference in the absorbency value of titanium at any dilution. However, the electroplated wires (p<0.001) the stainless steel wires (p<0.05) and the copper (P<0.001) were statistically significantly lower than those of medium only at all dilutions. Assessment as per ISO 10993, part 5, showed that electroplated wire was alloted to 'moderate cytotoxic' the titanium and stainless steel wire were 'non-cytotoxic' The results of this study indicate that the electroplated orthodontic wires need additional efforts to decrease cytotoxicity for their clinical applications.

Characteristics of Oil Shale as Unconventional Oil Resources (비재내형(非在來型) 원유(原油) 자원(資源)으로서의 오일셰일 특성(特性) 고찰(考察))

  • Na, Jeong-Geol;Chung, Soo-Hyun
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.62-67
    • /
    • 2008
  • Oil shale is a sedimentary rock that contains organic compounds called kerogen that are released as petroleum-like liquids by retorting. In order to evalute oil shale as alternative oil resources, the physical properties of oil shale samples from US and Russia were investigated and Fischer assays were carried out. Thermogravimetric analysis shows that thermal degradation of oil shale consisted of two stage processes, with hydrocarbon release from kerogen followed by $CO_2$ release by carbonate decomposition. Organic compounds in oil shale have an high hydrogen/carbon ratio, and therefore liquid hydrocarbons could be obtained easily. Shale oil yields from Russian and US oil shales by Fischer assay were 12.7% and 18.5%, respectively. The density and boiling point of shale oils are higher than that of Middle East crude oil, indicating that further upgrading processes are necessary for refinery. On the other hands, sulfur contents are relatively low, and the amounts of Vanadium and Nickel are extremely small in shale oil. It was found that paraffins were rich in US shale oil while main components of Russian shale oil were oxygenated hydrocarbons.

The Effect of Ghrelin on $Ca^{2+}$ Concentration in Thyroid FRTL-5 Cells

  • Kim, Byung-Joo;Park, Young-Joo;Park, Do-Joon;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.4
    • /
    • pp.195-200
    • /
    • 2004
  • Ghrelin is a newly discovered peptide, which is released from the stomach and neurons in the hypothalamic arcuate nucleus (ARC), and potently stimulates growth hormone release and food intake. In the present study, we investigated the effect of ghrelin on $[Ca^{2+}]_i$ in thyroid FRTL-5 cells. Ghrelin (5 nM) increased $[Ca^{2+}]_i$ and TSH (1 unit/l) had an additive effect on $[Ca^{2+}]_i$ when extracellular normal solution was 1.1mM $Ca^{2+}$ containing Coon's modified Ham's F12 medium. When $Ca^{2+}-free$ medium containing 2 mM EGTA replaced the above normal solution, ghrelin also induced a similar rise in $[Ca^{2+}]_i$. In the middle of $[Ca^{2+}]_i$ increment by ghrelin, nifedipine $(1\;{\mu}M)$, nickel $(100\;{\mu}M)$ and $La^{3+}\;(100\;{\mu}M)$ had no effect on $[Ca^{2+}]_i$. After endoplasmic reticulum was depleted by cyclopiazonic acid $(CPA;10\;{\mu}M)$, ghrelin caused no visible change on $[Ca^{2+}]_i$ in $Ca^{2+}-free$/2 mM EGTA solution. These results suggest that ghrelin can increase $[Ca^{2+}]_i$ through endoplasmic reticulum in thyroid FRTL-5 cells.

Metal Ion Released from Old Prostheses May Affect Oral Lesions: A Pilot Study

  • Ju, Hye-Min;Kim, Ji-Su;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.4
    • /
    • pp.131-135
    • /
    • 2018
  • Purpose: To investigate the correlation between the amount of salivary metal ions released from fixed prostheses and the period of restoration insertion, and to evaluate the correlation between the type and amount of metal ions in saliva and oral lesions (OL). Methods: Based on the oldest prosthesis, we divided patients into two groups: more than 5 years (n=19) and less than 5 years (n=10). Patients were also divided into two groups by another criteria: the one with the presence (n=15), and the one with absence (n=14) of OL, and the amounts of metal ions were examined. Metal ions-gold (Au), copper, cobalt (Co), chromium (Cr), nickel, zinc, aluminum, palladium (Pd), tin, and platinum (Pt)-were measured using laser ablation microprobe inductively coupled plasma mass spectrometry. Results: Significantly higher quantities of Co, Pt, and Pd ions were released in patients with fixed prosthesis of more than 5 years (p<0.05). Measurement of the average amount of salivary metal ions was performed on patients with and without OL - Significantly higher amounts of Cr, Pd and Au ions were released in patients with OL (p<0.05). Conclusions: Old prostheses (${\geq}5years$) released metal ions, and among them were Co, Pt and Pd ions more than others. Patients with OL showed significantly higher levels of ion release, especially Cr, Pd and Au. There was a positive correlation between the amount of a certain kind of released metal ions, especially Pd, and the development of OL. Salivary Pd ion released from old prostheses could affect the pathogenesis of OL; therefore, long-term follow-up is important.

A Comparative Study on the Current Status of Spectacle Frames Standards (안경테 표준규격 실태에 관한 비교 연구)

  • Yu, Dong-Sik;Kim, In-Su;Son, Jeong-Sik;Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: The aim of this study is to examine various national standards and to suggest problems and improvements on KS (Korean Industrial Standards) in spectacle frames. Methods: We surveyed the latest published KS, ISO (International Organization for Standardization), JIS (Japanese Industrial Standards), DIN (Deutsches Institut fur Normung) and ANSI (American National Standards Institute) standards with relating spectacle frames. The titles that were considered in comparative study were terms and vocabulary, measuring system and terminology, marking, requirements and test methods, formers, screw threads, and others. Results: There were 9 different languages such as English (USA and UK), French, Russian, Japanese, Chinese, German, Italian and Spanish for the lists of equivalent terms and vocabulary in all standards except KS and ANSI, but gave an explanation for terms and vocabulary in only KS. Complementary terms and definitions were not existed in annex of KS and ANSI for measuring system and terminology, but they were included in annex of standards of the others. KS and ANSI standard for requirements and test methods differed from the ISO revision. Except JIS and ANSI, standards of formers were almost identical. KS standard of screw threads were similar to JIS. Standards of welded joints and nickel release did not exist in KS. Conclusions: All standards except ANSI tend to follow ISO, especially DIN is almost entirely identical to ISO. But KS is behind the times because it has been amended lately or established in accordance with older editions of ISO. Therefore, in order to assist quality control and safety for spectacle frames, KS standards shall be superseded by the specifications which is identical to ISO within a reasonable time.

  • PDF

Influence of usage environment from camping cooking utensils on migration of hazardous metals (사용 환경에 따른 캠핑용 조리 기구로부터 유해금속 용출의 변화)

  • Lee, Jin-hee;Kim, Ji-Yeon;Park, Ye-Seul;Park, Sang-Gyu;Lee, Jae-Ho;Yoon, Jong-Ho;Kim, Gyung-Tae;Han, Gi-Dong
    • Food Science and Preservation
    • /
    • v.24 no.8
    • /
    • pp.1094-1102
    • /
    • 2017
  • Hazardous metals leaching experiment was carried out in accordance with various usage environments for camping cooking utensils distributed in the market. There was a significant difference in the degree of migration for lead, arsenic, cadmium and nickel defending on the solvent and how to use, although they were all appropriate for criteria. In general, the migrated amount of aluminum was increased in acidic condition, and the migrated amount of arsenic was increased in salty condition. Physical scratches increased the overall release of hazardous metals from the portable pots and pans for camping in all solvents. Especially, in 0.5% citric acid solution, cadmium was migrated by physical scratch in stainless steel and hard aluminum pots and pans. The longer the leaching time, the higher the migration of aluminum in acid condition and arsenic in basic condition. From these results, it is desirable to use the cooking utensil for camping without being exposed to strong acidic or basic solution and scratches in order to reduce the migration of hazardous metals from them.