• Title/Summary/Keyword: Ni-P roughness

Search Result 36, Processing Time 0.025 seconds

Thermal Cycle Reliabilties and Cracking Characteristics of Electroplated Cr/Ni-P Coatings (전해 Cr/Ni-P 도금막의 열 사이클 신뢰성 및 균열거동 분석)

  • Lee, Jina;Son, Kirak;Lee, Kyu Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.133-140
    • /
    • 2019
  • The effects of thermal cycle conditions on the bonding strength and crack propagation behaviors in electroplated Cr/electroplated Ni-P coatings were systematically evaluated. 1st heat treatment was performed at 500℃ for 3 hours after electroplating Ni-P, and then, 2nd heat treatment was performed at 750℃ for 6 hours after electroplating Cr. The measured bonding strength by ASTM C633 were around 25.6 MPa before thermal cycling, while it increased to 47.6 MPa, after 1,000 cycles. Increasing thermal cycles led to dominant fail mode with cohesive failure inside adhesive, which seemed to be closely related to the increasing bonding strength possibly not only due to higher Cr surface roughness, but also to penetrated channeling crack density. Also, increasing density of penetrated channeling cracks in electroplating Cr layer led to slightly stronger bonding strength due to mechanical interlocking effects of adhesive inside channeling cracks.

Effects of recycling on the mechanical properties and the surface topography of Nickel-Titanium alloy wires (재생 과정이 니켈-티타늄 호선의 물리적 성질과 표면 거칠기에 미치는 영향)

  • Lee, Sung-Ho;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.453-465
    • /
    • 2000
  • The purpose of this study was to investigate the change of mechanical properties, surface topography and frictional force of various nickel titanium wires after recycling. Three types of nickel-titanium wires and one type of stainless steel wire were divided to three groups: as-received condition(T0:control group), treated in artificial saliva for four weeks(T1) and autoclaved after being treated in artificial saliva(T2). Some changes were observed for the selected mechanical properties in tensile test, surface topography by means of SEM and 3D profilogram, and frictional coefficient. The findings suggest that: 1. Nickel-titanium wires demonstrated no statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity, but stainless steel wire demonstrated statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity between the groups(p<0.05). 2. NiTi, Optimalloy, Stainless Steel wires demonstrated increased pitting and corrosion in SEM finding. 3. Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater surface roughness(Ra and Rq) through 3D profilogram when compared with the control wires(p<0.05), but Sentalloy didn't demonstrate significant difference. 4. Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater maximum frictional coefficient when compared with the control wires(p<0.05), but Sentalloy didn't demonstrate significant difference The changes of surface roughness and frictional coefficient in NiTi and Optimalloy had no clinical implication. Consequently recycled nickel titanium wires demonstrated no clinical problem in tensile properties, surface topography and frictional coefficient.

  • PDF

The Evolution of Preferred Orientation and Morphology of NiO Thin Films under Variation of Plasma Source and RF Power (Plasma source와 RF power에 따른 NiO박막의 우선배향성 및 표면형상)

  • Hyunwook Ryu;Park, Jinseong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.121-121
    • /
    • 2003
  • NiO thin films are very attractive for use as an antiferromagnetic layer, p-type transparent conducting films, in electrochromic devices and functional sensor layer for chemical sensors, due to their excellent chemical stability, as well as optical, electrical and magnetic properties. In addition, (100)- and (111)-oriented NiO films can be used as buffer layers on which to deposit other oriented oxide films, such as c-axis-oriented perovskite-type ferromagnetic films and superconducting films, because of the similarity in symmetry of oxygen ion lattice and lattice constants between the NiO films and the oriented oxide films. Thus, controlling the crystallographic orientation and surface roughness of the NiO films for a buffer layer are very important.

  • PDF

Ni-Co Alloy Electroforming for Micro Mold Fabrication (마이크로 금형 제작을 위한 니켈-코발트 합금 전주기술개발)

  • Shin S. H.;Jeong M. K.;Kim Y. S.;Han S. H.;Hur Y. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.276-279
    • /
    • 2004
  • The factors affecting Ni-Co alloy electroforming were investigated to determine the optimum bath composition and electroplating parameters, like pH, temperature, and current density, suitable for high speed fabrication of a micro mold with longer lifetime. To obtain alloy deposits having uniform thickness and composition, electroplating parameters were finely tuned with home-made electroforming apparatus. Ni-Co alloy deposits had linearly increased Co with $Co^{2+}$ ion concentration in electroplating bath, and showing $412H_v$ of Victors hardness at $23wt\%$ of Co content. For Ni-Co alloy, sulfonate and diol related organic additives were very effective to alleviate its residual stress and surface roughness. The maximum deposition rate was $106{\mu}m/hr$ at 10ASD and the tensile strength of alloy deposit was 2 times larger than that of Ni only case.

  • PDF

Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature

  • Khalil, Wafaa A.;Natto, Zuhair S.
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.19.1-19.9
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files. Materials and Methods: The instruments (n = 15/each) were tested for cyclic fatigue in single- ($60^{\circ}$ curvature, 5-mm radius) and double-curved (coronal curvature $60^{\circ}$, 5-mm radius, and apical curvature of $30^{\circ}$ and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach $45^{\circ}$. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra). Results: EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p < 0.05) and both files were more resistant to cyclic fatigue in single-curved canals than double-curved canals (p < 0.05). EdgeEvolve files exhibited significantly more flexibility than did ProTaper Gold files (p < 0.05). Both files had approximately similar Ni and Ti contents (p > 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05). Conclusions: Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.

Effect of Ni plating and surface roughness on the bonding strength of thermoelectric module (열전 모듈의 접합강도에 미치는 Ni 도금 및 표면 거칠기의 영향)

  • Kim, Seong-Sun;Go, Byeong-Man;Son, In-Jun;Park, Gwan-Ho;Jo, Sang-Heum
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.347-348
    • /
    • 2015
  • Ni 도금 및 표면 거칠기에 따른 열전모듈의 접합강도 특성을 알아보기 위해 Bi-Te 소재 위에 Sand-blasting 방법을 사용하여 표면 거칠기를 조절하고, Ni-P 무전해 도금을 수행하였다. 접합강도 측정 및 표면 성분을 분석하기 위해 전단응력 측정기, FE-SEM을 이용하였다. Sand-blasting과 Ni 도금을 실시한 시편이 sand-blasting과 도금을 미실시한 대조군보다 전단응력이 높았고, 큰 방 수의 sand로 sand-blasting 한 시편일수록 전단응력이 더 높은 경향성을 보였다.

  • PDF

Property and Microstructure Evolution of Nickel Silicides for Poly-silicon Gates (게이트를 상정한 니켈 실리사이드 박막의 물성과 미세구조 변화)

  • Jung Youngsoon;Song Ohsung;Kim Sangyoeb;Choi Yongyun;Kim Chongjun
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.301-305
    • /
    • 2005
  • We fabricated nickel silicide layers on whole non-patterned wafers from $p-Si(100)SiO_2(200nm)$/poly-Si(70 nm)mn(40 nm) structure by 40 sec rapid thermal annealing of $500\~900^{\circ}C$. The sheet resistance, cross-sectional microstructure, surface roughness, and phase analysis were investigated by a four point probe, a field emission scanning electron microscope, a scanning probe microscope, and an X-ray diffractometer, respectively. Sheet resistance was as small as $7\Omega/sq$. even at the elevated temperature of $900^{\circ}C$. The silicide thickness and surface roughness increased as silicidation temperature increased. We confirmed the nickel silicides iron thin nickel/poly-silicon structures would be a mixture of NiSi and $NiSi_2$ even at the $NiSi_2$ stable temperature region.

Selective Contact Hole Filling by electroless Ni Plating (무전해 Ni 도금에 의한 선택적 CONTACT HOLE 충전)

  • 우찬희;권용환;김영기;박종완;이원해
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.4
    • /
    • pp.189-206
    • /
    • 1992
  • The effect of activation and electroless nickel plating conditions on contact properties was investi-gated for selective electroless nickel plating of Si wafers in order to obtain an optimum condition of con-tact hole filling. According to RCA prosess, p-type silicon (100) surface was cleaned out and activated. The effects of temperature, DMAB concentration, time, and strirring were investigated for activation of p-type Si(100) surface. The optimal activation condition was 0.2M HF, 1mM PdCl2, 2mM EDTA,$ 70^{\circ}C$, and 90sec under ultrasonic vibration. In electroless nickel plating, the effect of temperature, DMAB concentra-tion, pH, and plating time were studied. The optimal plating condition found was 0.10M NiSO4.H2O, 0.11M Citrate, pH 6.8, $60^{\circ}C$, 30minutes. The contact resistance of films was comparatively low. It took 30minutes to obtain 1$\mu\textrm{m}$ thick film with 8mM DMAB concentration. The film surface roughness was improved with decreasing temperature and decreasing pH of the plating solution. The best quality of the film was obtained at the condition of temperature $60^{\circ}C$ and pH 6.0. The micro-vickers hardness of film was about 800Hv. Plating rate of nickel on the hole pattern was slower than that of nickel on the line pattern.

  • PDF

Investigation of Eco-friendly Electroless Copper Coating by Sodium-phosphinate

  • Rha, Sa-Kyun;Lee, Youn-Seoung
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.264-268
    • /
    • 2015
  • Cu films were plated in an eco-friendly electroless bath (No-Formaldehyde) on Ni/screen printed Ag pattern/PET substrate. For electroless Cu plating, we used sodium-phosphinate ($NaH_2PO_2{\cdot}H_2O$) as reducing agent instead of Formaldehyde. All processes were carried out in electroless solution of pH 7 to minimize damage to the PET substrate. According to the increase of sodium-phosphinate, the deposition rate, the granule size, and rms roughness of the electroless Cu film increased and the Ni content also increased. The electroless Cu films plated using 0.280 M and 0.575 M solutions of sodium-phosphinate were made with Cu of 94 at.% and 82 at.%, respectively, with Ni and a small amount P. All electroless Cu plated films had typical FCC crystal structures, although the amount of co-deposited Ni changed according to the variation of the sodium-phosphinate contents. From these results, we concluded that a formation of higher purity Cu film without surface damage to the PET is possible by use of sodium-phosphinate at pH 7.

Ultra Precision Machining Technology Development of Subminiature Optics of Proximity and Wide Field of View (초정밀 가공기를 이용한 근접초소형 광시야각 광학계 기술 개발)

  • Kim, M.S.;Yang, S.C.;Kim, H.S.;Kim, G.H.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.4
    • /
    • pp.96-101
    • /
    • 2008
  • Due to improve form accuracy and surface roughness of a aspheric lens core that is made of Ni, the study is carried out on localization about a Subminiature Optics of Proximity and Wide Field of View. The required form accuracy P-V $0.2{\mu}m$ and surface roughness is Ra 10 nm. The design of experiment(DOE) is adopted to find a optimal cutting conditions which are spindle speed, depth of cut, feedrate. Finally, the effects of this study are replacing importation and strengthening competitiveness through the localization of the Subminiature Optics of Proximity and Wide Field of View.

  • PDF