• Title/Summary/Keyword: New zealand white rabbits

Search Result 272, Processing Time 0.025 seconds

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.

Comparison of Effects of Different Activation Treatments on Development of Rabbit Embryos Reconstituted with Fetal Fibroblast

  • Lee, H.J.;Yoo, J.G.;Cho, S.R.;Lee, S.L.;Chong, J.R.;Yeo, H.J.;Hwang, J.M.;Park, J.S.;Yea, E.H.;Rho, G.J.;Choe, S.Y.
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.22-22
    • /
    • 2001
  • To produce reconstituted rabbit embryos with fetal fibroblasts, the present study was evaluated the efficiencies of the different fusion and activation conditions as assessments of subsequent development and chromosome in the embryos. New Zealand White rabbits were used throughout the study. Fetal fibroblasts collected from 22-d of fetuses were cultured in DMEM + 10% FBS in 5% $CO_2$ in air. The culture was maintained for 10 passages. In every passage half of cell suspension were kept In frozen. From rabbits treated with FSH in 30% PVP solution and hCG, oocytes were surgically collected from oviducts at 14 h post-hCG injection and stripped off their cumulus cells by re-pipetting in a 300 IU hyaluronidase solution. Oocytes with an extruded first polar body and dense cytoplasm were enucleated by micromanipulation in Ham's F-10 medium+7.5 g/$m\ell$ cytochalasin B. Euncleation was confirmed under a fluorescence microscope after staining with 5 g/$m\ell$ bisbenzimide for 2 min. Each enucleated oocyte was injected with a fetal fibroblast into a perivitelline space. Reconstructed eggs were compared fusion rates either at 2.0 ㎸/cm or 1.6 ㎸/cm(60 sec, double pulses). After fusion, all eggs were activated with the combination of 5 M ionomycin (5 min) and 10 g/$m\ell$ cycloheximide (CHX, 3h), and cultured in CRlaa medium and transferred into TCM199+10% FBS on day 3. Although there was not significantly differ in fusion rate between treatments (60%, 2.0 ㎸/cm vs. 79.4%, 1.6 ㎸/cm), none of them in the eggs fused with 2.0 ㎸/cm developed to blastocyst. In comparison of development and chromosome status between different activation treatments (Group 1; 5 M ionomycin/10 g/$m\ell$ CHX, Group 2; 5 M ionomycin/5 g/$m\ell$ CHX + 2 mM DMAP after fusion with 1.6 ㎸/cm), there were not differ in cleavage and development rates (67.3% and 28.9% in Group 1; 67% and 33% in Group 2). All out of 8 embryos evaluated in Group 1 appeared a normal diploid chromosome sets and mean number of cells (Mean SEM) on day 4.5 of culture was 141.5 23.15 (n=8). It can be concluded that the use of cycloheximide has not happened in chromosome abnormalities, and fetal fibroblasts can be used for cloning in rabbit.

  • PDF

The Effect of Silk Fibroin/Nano-hydroxyapatite/Corn Starch Composite Porous Scaffold on Bone Regeneration in the Rabbit Calvarial Defect Model (가토 두개골 결손 모델에서 실크단백과 나노하이드록시아파타이트, 옥수수 녹말 복합물을 이용한 골 이식재 개발)

  • Park, Yong-Tae;Kwon, Kwang-Jun;Park, Young-Wook;Kim, Seong-Gon;Kim, Chan-Woo;Jo, You-Young;Kweon, Hae-Yong;Kang, Seok-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.6
    • /
    • pp.459-466
    • /
    • 2011
  • Purpose: This study evaluated the capability of bone formation with silk fibroin/nano-hydroxyapatite/corn starch composite scaffold as a bone defect replacement matrix when grafted in a calvarial bone defect of rabbits $in$ $vivo$. Methods: Ten New Zealand white rabbits were used for this study and bilateral round-shaped defects were formed in the parietal bone (diameter: 8.0 mm). The silk fibroin 10% nano-hydroxyapatite/30% corn starch/60% composite scaffold was grafted into the right parietal bone (experimental group). The left side (control group) was grafted with a nano-hydroxyapatite (30%)/corn starch (70%) scaffold. The animals were sacrificed at 4 weeks and 8 weeks. A micro-computerized tomography (${\mu}CT$) of each specimen was taken. Subsequently, the specimens were decalcified and stained with Masson's trichrome for histological and histomorphometric analysis. Results: The average ${\mu}CT$ and histomorphometric measures of bone formation were higher in the control group than in the experimental group at 4 weeks and 8 weeks after surgery though not statistically significant ($P$ >0.05). Conclusion: The rabbit calvarial defect was not successfully repaired by silk fibroin/nano-hydroxyapatite/corn starch composite scaffold and may have been due to an inflammatory reaction caused by silk powder. In the future, the development of composite bone graft material based on various components should be performed with caution.

Acute toxicity, Dermal and Ocular Irritation Studies of Taglisodog-eum ointment (탁리소독음 피부외용제형의 급성경피독성시험, 피부자극시험 및 안점막자극시험)

  • Lee, Jung Bok;Choi, Jae Hwan;Kim, Hee Taek;Kim, Yun Kyung;Yu, Young Beob
    • Herbal Formula Science
    • /
    • v.24 no.4
    • /
    • pp.289-300
    • /
    • 2016
  • Objectives : Taglisodog-eum(TSE), a poly herbal formula, has been widely used to improve carbuncles by removing inflammation of the lymphatic channels in Traditional Korean Medicine. We previousely reported the action mechanism of TSE on experimental atopic dermatitis and the establishment of formulation for TSE ointment. In this study, we examined the toxicity test on skin and eye irritation by TSE ointment to prove the safety of Taglisodog-eum ointment in clinical use. Methods : Acute skin toxicity of the TSE ointment was evaluated in Sprague-Dawley(SD) rats. After dermal administration of TSE ointment(2,000mg/kg), body weight, mortality, and clinical signs of the rats were observed for 14days. Primary skin irritation and ocular irritation tests for TSE ointment were performed in male New Zealand White Rabbits. In dermal and ocular irritation test, body weight, mortality, clinical signs, Primary Irritation Index(P.I.I.), and The Index of Acute Ocular Irritaion(I.A.O.I.) of rabbit were observed after applying at abraded skin and eye balls with Taglisodog-eum ointment. Results : In the results of acute skin toxicity, no significant differences were found in body weight, the clinical sign and the mortality between control and TSE ointment treated group. In primary dermal irritation test, body weight, the clinical sign and the mortality were not significantly changed and Primary Irritation Index(P.I.I.) was 0.8, indicating TSE ointment as weak irritant material. In ocular irritation test, The Index of Acute Ocular Irritaion was 0.0, indicating TSE ointment as non-irritating to the eye of the rabbits. To evaluate toxicity of the TSE ointment in animal test, body weight, the clinical signs, the skin and eye irritation check were conducted; TSE ointment was considered to be weak dermal irritant in test animals. The no response of eye irritation test was observed in this experimental condition. Conclusions : According to the above toxicity test, We consider that this results is helpful for saying about the safety of TSE ointment in clinical use.

Incidence and Morphology of Cysticercus pisiformis (Taenia pisiformis Bloch 1780: Taeniidae) Collected from Rabbits in Korea (토끼에서 분리(分離)된 두상(豆狀) 낭미충(囊尾蟲)의 감염실태조사(感染實態調査) 및 형태학적관찰(形態學的觀察))

  • Kang, Yung-bai
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.1
    • /
    • pp.101-108
    • /
    • 1987
  • A total of 213 rabbits was investigated from July 1981 to June 1986, for the survey on the incidence of Cysticercus pisiformis infections and the morphological characteristics were observed for the descriptions on the scolexes of the cysts collected. The results obtained were summarized as follows; The overall infection rate was revealed as high as 21.6% and it increased annually with the secular trend equation Y=7.45X+5.87 when, Y=infection rate estimated, X=year 0(1981) to 5 (1986). The incidence was no relation with the sexes of the host, but it was higher in the short-haired New Zealand White than in the long-haired Angola. It was also revealed that the liver was the most parasitized organ (39.1%) and that 48 cases were double infections in two organs, such as the mesentery, the stomach or the kidney. The mean size of the cysts measured was 7.04mm in length and 4.62mm in width. There were four suckers and a rostellum on the top of the scolex identified inside the cyst. The hooks were arranged in two rows, the large-type inner hooks (mean $250{\mu}m$ in length) and the small-type outer hooks (mean $150{\mu}m$ in length).

  • PDF

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

Effect of scan-bio laser therapy on arthropathy in rabbits (토끼의 관절병증에 미치는 SCAN-BIO 레이저의 치료효과)

  • Cho, Hyung-Jin;Kim, Young-Su;Oh, Dong-Min;Sim, Kyung-Mi;Kang, Seong-Soo;Lim, Sung-Chul;Cho, Yong-Seong;Lee, Soo-Han;Choi, Seok-Hwa;Bae, Chun-Sik
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.3
    • /
    • pp.475-482
    • /
    • 2004
  • For the induction of arthropathy, 4% hydrogen peroxide ($H_2O_2$) was injected for 4 weeks into the intra-articular space of the 25 New Zealand white rabbits to damage articular cartilage. The verification of arthropathy induction and the effect of scan-bio laser treatment were determined by measuring superoxide dismutase (SOD) activity, by observing gross and histopathologic findings. The SOD activity increased by about 40% in arthropathy group, as compared to controls. Although SOD activity in arthropathy group was not significantly different from the 2-week group, it was significantly different from the 4-week control and treatment groups. There was also a significant difference between the 4-week control and treatment groups. Grossly, erosions formed on the articular cartilage surface, and the lateral femoral condyle was damaged in arthropathy group. In comparison, there was slight, but not significant, progression of the lesion in the 2-week control group, and no difference between the 2-week treatment and control groups. Conversely, severe erosions damaged the articular cartilage in the 4-week control group. Cartilage proliferation was seen in gross observations in the 4-week treatment group, suggesting a treatment effect. Histopathologically, there was slight articular surface damage and apoptosis in arthropathy group, and serious cartilage damage, despite slight chondrocyte proliferation, in the 4-week control group. By contrast, the 4-week treatment group showed chondrocyte replacement, with close to normal articular cartilage on the articular surface. There was significant cartilage proliferation with regeneration of the articular cartilage on the articular surface in the group treated with low-level laser, as compared to control group, when arthropathy was induced by $H_2O_2$ injections. Therefore, low-level laser was effective in the treatment of chemically induced arthropathy.

A COMPARATIVE STUDY OF VARIOUS TYPE OF AUTOGENEOUS BONE GRAFT ON THE RABBIT-SKULL DEFECT HEALING (가토 두개골에 이식한 다양한 형태의 자가골에 의한 골성 회복 양상 비교 평가)

  • Choi, So-Young;Lee, Su-Youn;Kim, Jin-Wook;Kim, Chin-Soo;Lee, Sang-Han;Shin, Hong-In;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.428-434
    • /
    • 2008
  • Introduction: Piezosurgery device is one of the most commonly used instrument on the intraoral surgery such as maxillary sinus lift and autogeneous bone graft. Piezosurgery instrument also contains the tips that are manufactured especially for the convenient bone graft, which now many surgeons apply them for collecting bone graft materials in the curettage method for the restoration of skull defects. However, objective data has not been shown concerning the effects about bone graft with using Piezosurgery. Therefore we investigated the effects of Piezosurgery on the rabbit-skull defect healing. Materials & Methods: To investigate the regeneration of the bony defect with various bone graft, 10 adult New Zealand white rabbits (average weight : $2.8{\pm}0.3kg$, about 12weeks) were used. The four circular bony defects measuring 6mm in diameter were made with Piezosurgery device on each rabbit cranial bone. The harvested bone tissues during defect formation were also used for autogeneous bone graft. They were grafted into the defects in a various type; block type (Group 1), particulated type by the bone mill (Group 2), chopped type by curette shaped Piezosurgery tip (Group 3), the defect without any graft was served as control (control group). The animals were sacrificed after 6 weeks and bone regeneration capacity was evaluated histomorphometrically. Result & Conclusion: Autogeneous bone graft harvested using a Piezosurgery instrument showed satisfactory bone regeneration. There was no conspicuous difference bone prepared among by bone mill or Piezosurgery and block bone graft. Therefore, the bone harvested from the intraoral site near the operation field using the piezosurgery device can be a feasible and reliable graft for intraoral bony defects.

THE EFFECTS OF BIO-$OSS^{(R)}$ AS A SCAFFOLDS DURING SINUS BONE GRAFT USING MESENCHYMAL STEM CELLS IN RABBIT (가토에서 자가유래 골아줄기세포를 이용한 상악동 골 이식술시 비계체로서 Bio-$Oss^{(R)}$의 효과에 관한 연구)

  • Lee, Jun;Sung, Dae-Hyuk;Choi, Jae-Young;Choi, Sung-Rym;Cha, Su-Ryun;Jang, Jae-Deog;Kim, Eun-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.405-418
    • /
    • 2007
  • Mesenchymal stem cells(MSCs) have been though to be multipotent cells that can replicate that have the potential to differentiate into lineages of mesenchymal tissue including the bone, cartilage, fat, tendon, muscle, and marrow stroma. Especially, scaffolds to support cell-based tissue engineering are critical determinants of clinical efforts to regenerate and repair the body. Selection of a matrix carrier imvolves consideration of the matrix's role as a scaffold for physical support and host tissue integration as well as its ability to support of synergize the osteoinductive program of the implanted mesenchymal stem cell. The aim of this study is to evaluate the effect of autobone and Bio-$Oss^{(R)}$ to adherent mesenchymal stem cells as scaffolds on sinus augmentation with fibrin glue mixture in a rabbit model. 16 New Zealand White rabbits were divided randomly into 4 groups based on their time of sacrifice(1, 2, 4 and 8 weeks). First, mesenchymal stem cells were isolated from iliac crest marrow of rabbits and expanded in vitro. Cell culture was performed in accordance with the technique described by Tsutsumi et al. In the present study, the animals were sacrificed at 1, 2, 4 and 8 weeks after transplantation, and the bone formation ability of each sides was evaluated clinically, radiologically, histologically and histomorphologically. According to the histological observations, autobone scaffolds group showed integrated graft bone with host bone from sinus wall. At 2 and 4 weeks, it showed active newly formed bone and neovascularization. At 8 weeks, lamellae bone was observed in sinus graft material area. Radiologically, autobone with stem cell showed more radiopaque than Bio-$Oss^{(R)}$ scaffolds group. there were significant differences in bone volume between 4 and 8 weeks(p<0.05).

The Effects of Calcium-Phosphate Coated Xenogenic Bone and Type I Collagen for Bone Regeneration on the Calvarial Defects in Rabbits (Ca-P 박막 이종골과 제 1형 교원질이 토끼 두개골 결손부의 골재생에 미치는 영향)

  • Kim, Chang-Han;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.223-241
    • /
    • 2004
  • The purpose of this present study evaluated the osseous response around Ca-P coated xenogenic bone and compared osteogenic potential of Ca-P coated xenogenic bone to that of combination with type I collagen derived from bovine tendon as a biocompatible binder to prevent migration of bone particle on the repair of calvarial defects in rabbits. To study the effects of Ca-P coated xenogenic bone and collagen on bone healing, four 5-mm-diameter skull defect were made in calvaria with trephine filled with an autogenous bone chip or Ca-P coated xenogenic bone or Ca-P coated xenogenic bone and type I collagen (1:1 mixture by volume) or left empty. The defects were evaluated histologically at 1, 2, 4 and 8 weeks following implantation. Ca-P coated xenogenic bone at the calvarial defects of rabbits showed osteoconductivity at the margin of defect in the early stage of bony healing, but no direct contact with new bone was observed. With time passed by, it was resorbed slowly and showed consistent inflammatory reaction. An additional use of type I collagen derived from bovine tendon improved clinical handling, but no new bone formation was observed histologically. Above all, autogenous bone graft showed most prominent healing in quantity and density of new bone formation. According to this study, the use of Ca-P coated xenogenic bone alone and combination with type I collagen did not showed effective healing in quantity and density of new bone formation.