• Title/Summary/Keyword: Neutral System

Search Result 1,091, Processing Time 0.035 seconds

A Study on the One Bath Two Step Dyeing of Nylon/ Cationized Cotton Blends with Acid Dye/Direct Dye (나일론/카티온화 면 혼방품의 산성염료/직접염료에 의한 1욕 2단 염색에 관한 연구)

  • 성우경
    • Textile Coloration and Finishing
    • /
    • v.12 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • The conventional one bath exhaust dyeing system of nylon]/cotton blends with acid dye/direct dye involves a lot of neutral salt which affect dyeability of acid dyes. Because of conventional one bath exhaust dyeing system of nylonl/cotton blends with acid dye/direct dye needs acid dyes adjusted at a neutral liquor, suitable acid dye is limited. To improve dyeing property of nylon/cotton blends, cotton component was pretreated with cationizing agent containing chlorohydrine group in aqueous solution of sodium hydroxide. This study was carried out to investigate dyeing possibilities of nylon/cationized cotton blends with acid dye/direct dye in a non-neutral salt dyebath by one bath two step method. The concentration of direct dye was 1.0%, 0.7%, 0.3%o.w.f. respectively at a non, 1%, 3%owf of reserving agent for being almost equal color strength between nylon and 3% cationized cotton when nylon/3% cationized cotton blends was dyed with acid dye/direct dye at concentration of acid dye(1%o.w.f.) by one bath two step method.

  • PDF

Sampled Fuzzy Controller for discrete networked control systems (샘플치 퍼지 제어기를 이용한 이산 퍼지 시스템 제어)

  • Kook, Song-Min;Bae, Park-Jin;Kim, Jong-Seon;Hoon, Joo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1783-1784
    • /
    • 2008
  • This paper presents a novel control technique to deal with networked control systems with neutral timedelay, which is known to highly degrade the control performance of the controlled system. The stability analysis and design method for a sampled-data fuzzy controller for discrete networked control systems (NCS). The neutral time-delay and sampling activity will complicate the NCS. And it make the stability analysis much more difficult than that for a continuous-time NCS. Based on the fuzzy control approach, linear matrix inequality (LMI)-based stability conditions are derived to guarantee the neutral T-S fuzzy system stability. The simulation results and practical experiments illustrate that the proposed controller design is realistic.

  • PDF

Fault Diagnosis and Neutral-Point Voltage Control according to Faults for a Three-level Neutral-Point-Clamped PWM Inverter (NPC 3-레벨 PWM 인버터에서 고장 발생에 따른 고장 진단과 중성점 전압 제어)

  • Son Ho-In;Kim Tae-Jin;Kang Dae-Wook;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.11-16
    • /
    • 2003
  • The 3-level converter/inverter system is very efficient in the ac motor drives of high voltage and high power application. This paper proposed a simple method to diagnose faults using change of current vector pattern in space vector diagram when the faults occurrence in the 3-level inverter and a control method that can protect system from unbalance of the neutral point voltage according to faults. The validity of the proposed method is demonstrated by the simulation results.

  • PDF

Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements (에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거)

  • Kim, Hyo-Seong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF

Fault Diagnosis and Neutral Point Voltage Control Under the Switch Fault in NPC 3-Level Voltage Source Inverter (NPC 3-레벨 인버터의 스위치 고장시 고장 진단과 중성점 불평형 전압 제어)

  • Kim Tae-Jin;Kang Dae-Wook;Hyun Dong-Seok;Son Ho-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.231-237
    • /
    • 2005
  • Many conventional multi-level inverters have detected switching faults by using the over voltage and current. However, fault detection of the switching elements is very difficult because the voltage and current due to each switching fault decrease more than the normal operation. Moreover, the dc-link unbalancing voltage causes a serious problem in the safety and reliability of system when the 3-level inverter faults occur Therefore, this paper proposes the simple fault diagnose method and the neutral-point-voltage control method that can protect the 3-level inverter system from the unbalancing voltage of the do-link capacitors when the faults of switching elements occur in the 3-level inverter that is very efficient in ac motor drives of the high voltage and high power applications. Through experiment results, the validity of the proposed method is demonstrated.

Delay-Dependent Guaranteed Cost Control for Uncertain Neutral Systems with Distributed Delays

  • Li, Yongmin;Xu, Shengyuan;Zhang, Baoyong;Chu, Yuming
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.1
    • /
    • pp.15-23
    • /
    • 2008
  • This paper considers the problem of delay-dependent guaranteed cost controller design for uncertain neutral systems with distributed delays. The system under consideration is subject to norm-bounded time-varying parametric uncertainty appearing in all the matrices of the state-space model. By constructing appropriate Lyapunov functionals and using matrix inequality techniques, a state feedback controller is designed such that the resulting closed-loop system is not only robustly stable but also guarantees an adequate level of performance for all admissible uncertainties. Furthermore, a convex optimization problem is introduced to minimize a specified cost bound. By matrix transformation techniques, the corresponding optimal guaranteed controller can be obtained by solving a linear matrix inequality. Finally, a simulation example is presented to demonstrate the effectiveness of the proposed approach.

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

The expectation effects of a decrease in neutral wires Zero Sequence harmonic currents in 3 phases - 4 wires systems (3상4선식 계통에서 중성선 영상고조파 저감에 따른 기대효과)

  • Kang, Chang-Won;Lee, Sung-Woo;Jung, Yeun-Hea;Kim, Se-Dong;Lee, Won-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.715-719
    • /
    • 2002
  • Recently, Dangers due to harmonics emanated from all sorts of machinery have been on the increase with the development in industry. One of them is that Zero Sequence harmonic currents flow from the neutral wires in 3 phases - 4 wire systems. The flowing of harmonic currents in neutral wires brings about the superheating and falloff in output of transformer, the overheating of them, a rise in ground potential and the wrong movement of machinery, so has a bad influence on this system. To develop the machinery to decrease neutral wires Zero sequence harmonic currents and apply it help solve these problems and bring about the effects of a improvement in power factor and energy savings.

  • PDF

A Study for a Automotive Neutral Gear Rattle and the Clutch Torsional Characteristics (자동차 공회전시 기어래틀과 클러치 비틀림특성에 대한 연구)

  • Hong, D.P.;Chung, T.J.;Tae, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.30-41
    • /
    • 1995
  • Gear rattle is a source of vibration and noise in automotive gearbox casing and generally occurs at or near system resonant frequencies. The neutral gear rattle of the gearbox. is affected by the stiffness and hysteresis torque in the clutch disk and drag torque determining balancing point of the clutch disk operating range. The experiment is carried out in the pre-damper type clutch and a manual transmission of a automobile equipped for inline four-sylinder four-cycle 1.5L MPI engine and the computer simulation is executed by 5th order Runge-Kutta method. The results of the simulation analysis and experimental studies show the dynamic behavior of clutch and a phenomenon of the neutral gear rattle with respect to drag torque and torsional characteristics of the clutch.

  • PDF

Maximum Entropy Algorithm and its Implementation for the Neutral Beam Profile Measurement

  • Lee, Seung-Wook;Gyuseong Cho;Cho, Yong-Sub
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.329-334
    • /
    • 1997
  • A tomography algorithm to maximize the entropy of image using Lagrangian multiplier technique and conjugate gradient method has been designed for the measurement of 2D spatial distribution of intense neutral beams of KSTAR NBI(Korea Superconducting Tokamak Advanced Research Neutral Beam Injector) which is now being designed. A possible detection system was assumed and a numerical simulation has been implemented to test the reconstruction quality of given beam profiles. This algorithm has the good applicability for sparse projection data and thus, can be used for the neutral beam tomography.

  • PDF