• Title/Summary/Keyword: Neutral Position

Search Result 326, Processing Time 0.022 seconds

Analysis of the Perception of Autonomous Vehicles Using Text Mining Technique (텍스트 마이닝 기법을 활용한 자율주행자동차 인식분석연구)

  • Im, I-Jeong;Song, Jae-In;Lee, Ja-Young;Hwang, Kee-Yeon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.6
    • /
    • pp.231-243
    • /
    • 2017
  • The purpose of this study is to improve the social acceptance of AVs by analyzing the citizen's perception using an emotional analysis technique which belongs to a type of text mining. The source of the data is originated from 3 year accumulated internet articles and comments on AV from 164 newspapers and Naver. According to the study results, there exists a positive perception on AVs, although negative ones are more frequent than the positive. Also most of people take neutral position on AV due to the unfamiliarity and lack of experience on AVs And these problems needs to be responded before AV's commercialization through continuous analyses on the perception and social acceptance.

A Comparative Study using Bibliometric Analysis Method on the Reformed Theology and Evangelicalism (개혁신학과 복음주의에 관한 계량서지학적 비교 연구)

  • Yoo, Yeong Jun;Lee, Jae Yun
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.29 no.3
    • /
    • pp.41-63
    • /
    • 2018
  • This study aimed at analyzing journals and index terms, authors of the reformed theology and evangelicalism, neutral theological position by using bibliometrical analyzing methods. The analyzing methods are average linkage and neighbor centralities, profile cosine similarities. Especially, when analyzing the relationship between authors, we interpreted the research topic by finding the key shared index terms between the authors. In the journal analysis results, 9 journals were largely clustered together in the two clusters of the reformed theology and evangelicalism, but Presbyterian Theological Quarterly that is thought to be a reformed journal was clustered in evangelical cluster. In the index terms analysis results of the clusters, the reformed theology and evangelicalism were key words representing the two clusters. In the authors' analysis results, we had 9 clusters and the Presbyterian theologian studying the reformed theology had the four clusters and the non-Presbyterian theologian had the 5 clusters. Therefore, we consistently had the two clusters of the reformed theology and evangelicalism in all the analysis of the journals and the index terms, the authors.

A Study on the Result of Test Site on BMD (골다공증 검사 시 검사부위에 따른 결과에 대한 고찰)

  • Hong, Dong-Hee;Han, Sang-Hyun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • The measurement of Korea people's Radial-terminal region were frequently measure of the left hand of Radial-terminal region due to the most Korean's are right-handed and it occasionally showed incorrect results. Therefore, in this study, we accessed a correlation with error of measurement and reduced the measurement error invalid. We reviewed 50 adults patients, from March 2012 for a certain period of time, visited the orthopedic center for the neutral position of forearm of plain radiography and measured the left side of the distal radial-terminal region containing the terminal region of the right distal radius. Then we have compared and analysed both T-score. As a result, the lower value of left wrist were 45 out of 75 which is approximately 60% of left wrist group while the lower value of right wrist were 30 out of 75 which is approximately 40% of right wrist group.

New Transition Metal Mediated Alkylation Reaction of arachno-$S_{2}B_{7}H_{8}$, Insertion Reaction of arachno-$S_{2}B_{7}H_{8}^{-}$ with $(CO)_{5}M$ {${C(R_{1})(R_{2})}$} $(M=Cr,\;W;\;R_{1}=CH_{3},\;C_{6}H_{5};\;R_{2}=OCH_{3},\;SC_{6}H{5})$: Synthesis and Characterization of arachno-$4-RCH_{2}-6,8-S_{2}B_{7}H_{8}\;(R=CH_{3},\;IIa;\;C_{6}H_{5},\;IIb)$

  • Hee-Joo Jeon;Jae-Jung Ko;Kang-bong Lee;Sang Ook Kang
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.113-117
    • /
    • 1993
  • Good yield synthetic routes for the production of new B-alkyl-dithiaborane clusters are reported. The syntheses of the B-alkyl-dithiaboranes are based on the use of Fischer-type carbene reagents to activate the B-H bonds of dithiaborane for alkyl-addition reactions and are the first examples of transition-mediated reactions of dithiaborane to be reported. Thus, reactions employing arachno-$S_2B_7H_8$- and $(CO)_5M{C(R_1)R_2}$ (M = Cr, W; $R_1 = CH_3,\;C_6H_5;\; R_2 = OCH_3,\;SC_6H_5)$ were found to yield the intermidiate anions I, $[(CO)_5M{C(R_1)R_2S_2B_7H_8}]^-$, which upon protonation gave the corresponding neutral, air-sensitive cluster arachno-4-$RCH_2-6,8-S_2B_7H_8(R=CH_3,\;IIa;\;C_6H_5,\;IIb)$ range from 30 to 35% yield. Complexes IIa and IIb are isoelectronic with arachno-6,8-$S_2B_7H_9$ and, on the basis of the spectroscopic data, are proposed to adopt a similar arachno cage geometry in which an $RCH_2$ units are substituted to 4 position boron atom of the arachno-6,8-$S_2B_7H_9$.

Photoluminescence Studies of ZnO Nanorods Grown by Vapor Phase Transport (기상이동법으로 성장한 산화아연 나노막대의 포토루미네슨스 분석)

  • Kim, Soaram;Cho, Min Young;Nam, Giwoong;Kim, Min Su;Kim, Do Yeob;Yim, Kwang Gug;Leem, Jae-Young
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.10
    • /
    • pp.818-822
    • /
    • 2011
  • ZnO nanorods were grown on Au-coated Si substrates by vapor phase transport (VPT) at the growth temperature of $600^{\circ}C$ using a mixture of zinc oxide and graphite powders as source material. Au thin films with the thickness of 5 nm were deposited by ion sputtering. Temperature-dependent photoluminescence (PL) was carried out to investigate the optical properties of the ZnO nanorods. Five peaks at 3.363, 3.327, 3.296, 3.228, and 3.143 eV, corresponding to the free exciton (FX), neutral donor bound exciton ($D^{\circ}X$), first order longitudinal optical phonon replica of free exciton (FX-1LO), FX-2LO, and FX-3LO emissions, were obtained at low-temperature (10 K). The intensity of these peaks decreased and their position was red shifted with the increase in the temperature. The FX emission peak energy of the ZnO nanorods exhibited an anomalous behavior (red-blue-red shift) with the increase in temperature. This is also known as an "S-shaped" emission shift. The thermal activation energy for the exciton with increasing temperature in the ZnO nanorods is found to be about 26.6 meV; the values of Varshni's empirical equation fitting parameters are = $5{\times}10^{-4}eV/K$, ${\beta}=350K$, and $E_g(0)=3.364eV$.

An Analysis of Muscular Activity of the Long and Short Heads of Biceps Brachii Muscle According to the Elbow Flexion Angle (위팔두갈래근의 긴갈래와 짧은갈래의 팔굽관절 굽힘 각도에 따른 근활성도 분석)

  • Kim, Jeong-Wook;Park, Min-Chull
    • PNF and Movement
    • /
    • v.18 no.1
    • /
    • pp.127-132
    • /
    • 2020
  • Purpose: This study aimed to investigate the impact of resistance on the muscle activities of the long and short heads of the biceps brachii, according to the elbow angle in supination, and the difference in muscle activity between the long and the short heads. Methods: This study was conducted with 22 men in their 20s who voluntarily agreed to participate. With the glenohumeral joint neutral in a position of supination, the elbow angle was randomly moved to 0°, 30°, 60°, and 90°. Using an 8-channel surface EMG while the participants held a 2-kg. dumbbell, the muscle activities of the long and the short heads of the biceps brachii were measured. The measured data were statistically processed using SPSS for Windows 12.0. For the activities of the short and the long heads according to the angle, a one-way ANOVA was conducted, and subsequently, to check the results of an analysis of the difference between groups, an LSD post-hoc test was conducted. An independent t-test was used to compare the activities of the long head and the short head according to the angles. Results: The analysis of the impact of the load of the dumbbell at each elbow angle on the muscle activities of the long and short heads of the biceps brachii revealed significant differences in both heads (p < 0.05). The result of the post-hoc analysis showed significant differences in both heads at angles between 0° and 30°, between 0° and 60°, and between 0° and 90°. Analysis of the impact of the load of the dumbbell in supination on the muscle activities of the long and short heads showed a significant difference at the angle between 0° and 30° (p < 0.05). Conclusion: The long head of the biceps brachii mainly acts in supination; however, in supination at elbow-bending angles of 60° and 90°, there was no difference in muscle activity between the short head and the long head.

Effects of a Notebook Computer Supporter on Biomechanical Characteristics in Wrist Joint Muscles of Healthy Young Adults (노트북 거치대가 건강한 젊은 성인 손목관절근육의 생체역학적 특징에 미치는 영향)

  • Ma, Sung-Ryong;Song, Chiang-Soon
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.391-399
    • /
    • 2021
  • Purpose: As laptop use increases throughout the COVID-19 pandemic and its use outside of traditional workstations proliferates, it is imperative to expand the limited research available regarding ergonomic exposure. This study aimed to identify the effects of a laptop supporter on biomechanical characteristics in the wrist joint muscles of healthy young adults. Methods: This was a cross-sectional observational study design with thirty-four healthy young adults as participants. They conducted a typing exercise performed under two different conditions, which were with and without a notebook computer supporter. This study measured the biomechanical characteristics of the muscles of the wrist joints including the flexor carpi ulnaris (FCU), the flexor carpi radialis (FCR), the extensor carpi radialis longus (ECRL), and the extensor carpi ulnaris (ECU). Measurements were taken three times: before typing, immediately after typing for 30 minutes with a supporter, and immediately after typing for 30 minutes without a supporter. The statistical method to compare the three different measurement conditions was the repeated measures ANOVA. Results: The participants showed significantly different levels of dynamic stiffness in both the FCU before typing and immediately after 30 minutes of typing with a supporter, and showed significantly different levels of dynamic stiffness in the FCR before typing and immediately after 30 minutes of typing with a supporter. The dynamic stiffness level immediately after 30 minutes of typing without a supporter was significantly different than that immediately after 30 minutes of typing with a supporter. However, the muscle tone was not significantly different among the three different conditions. Conclusion: The results of this study revealed that a laptop supporter used to correct the eye level of the electronic screen increases the dynamic stiffness of the wrist joint flexors, so it is necessary to consider the neutral position of the wrist joint during typing.

Cervical Open-Door Laminoplasty by Hydroxyapatite Implant Insertion Without Suturing

  • Kawanabe, Yoshifumi;Fujimoto, Motoaki;Sato, Tsukasa
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.362-367
    • /
    • 2018
  • Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.

Exploring 'Tradition' Terminology Trends based on Keyword Analysis (1920~2017) (키워드 분석 기반 '전통' 용어의 트렌드 분석 (1920~2017))

  • Kim, Min-Jeong;Kim, Chul Joo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.421-431
    • /
    • 2018
  • The purpose of this study is to analyze the trends of 'traditional' terminology in Korea. We focus on an empirical investigation of how media reports are conveying 'tradition' terminology in our society by applying text mining and social network analysis techniques. The analysis covered 2,481,143 news articles related to 'tradition' terminology that appeared in the media since the 1920's. In this research, frequency analysis, association analysis and social network analysis were used on articles related to 'tradition' terminology from 1920 to 2017 by decade. By applying these data science techniques, we can grasp the meaning of social culture phenomenon related 'tradition' with objective and value-neutral position and understand the social symbolism which contains the tradition of the times.

Rotating Arm Internally Can Change the Arthroscopic Diagnosis of a Partial-thickness Tear of the Subscapularis

  • Kim, Hyungsuk;Song, Hyun Seok;Kang, Seung Gu;Han, Sung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.3
    • /
    • pp.135-138
    • /
    • 2019
  • Background: The aims of this study were (1) to examine the footprint of the subscapularis tendon using the traditional posterior portal and $30^{\circ}$ arthroscope by simple internal rotation of the arm during surgery, and (2) to classify the pattern of a subscapularis partial-thickness tear. Methods: This study analyzed a total of 231 patients with a partial-thickness subscapularis tear from 550 consecutive patients undergoing an arthroscopic operation who had a visualization of the subscapularis tendon footprint by internal rotation of the arm. First, the patients were classified into four categories according to the tear pattern: (1) stable lamination, (2) unstable lamination, (3) avulsion, and (4) laminated avulsion. Randomized arthroscopic videos were reviewed blindly by two independent orthopedic surgeons. The pattern of the tear of the subscapularis at the neutral position and after internal rotating the arm were assessed and compared with the treatment decision (level IV case series). Results: Stable lamination, unstable lamination, avulsion, and laminated avulsion were observed in 9.1% (n=21), 20.8% (n=48), 41.1% (n=95), and 29.0% (n=67) of cases, respectively. In 145 out of 231 cases (62.8%), the decision was changed after inspecting the footprint after internal rotation of the arm, and the treatment method was changed in 116 (50.2%) cases. Conclusions: In a subscapularis tendon partial-thickness tear, inspecting the footprint of the subscapularis tendon is essential to diagnosing and deciding on the appropriate treatment. In addition, simply internal rotating the arm during surgery when using the traditional posterior portal and $30^{\circ}$ arthroscope can be a valuable method.