• Title/Summary/Keyword: Negative voltage

Search Result 941, Processing Time 0.029 seconds

Control of DC-side Voltage Unbalance among Phases in Multi-level H-Bridge STATCOM with Unbalanced Load (불평형부하를 가지는 다단 H-bridge STATCOM에서 상간 직류전압 불평형의 제어)

  • Kwon, Byung-Ki;Jung, Seung-Ki;Kim, Tae-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.332-341
    • /
    • 2014
  • A cascaded H-bridge multi-level STATCOM(STATic synchronous COMpensator), which is composed of many cell inverters with independent dc-sources, generates inevitably dc-side voltage unbalance among phases when it compensates unbalanced load. It comes from the difference of flowing active power in each phase when this compensator makes negative-sequence current to eliminate the unbalance of source-side current. However, this unbalance can be controlled by injecting zero-sequence current which is decoupled with grid currents, so the compensator can work well during this balancing process. Both a feedback control algorithm, which produces zero-sequence current proportional to dc-side voltage unbalance within each phase, and a feedforward control algorithm, which makes zero-sequence current directly from the compensator's negative-sequence current, were proposed. The dc-side voltage of each phase can be controlled stably by these proposed algorithms in both steady-state and transient, so the compensator can have fast response to satisfy control performance under rapid changing load. These balancing controllers were implemented and verified via simulation and experiment.

Equivalent Grid Impedance Estimation Method Using Negative Sequence Current Injection in Three-Phase Grid-connected Inverter (3상 계통 연계형 인버터의 역상분 전류 주입을 이용한 계통 등가 임피던스 추정 기법)

  • Park, Chan-Sol;Song, Seung-Ho;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.526-533
    • /
    • 2015
  • A new algorithm is proposed for the estimation of equivalent grid impedance at the point of common coupling of a grid-tie inverter output. The estimated impedance parameter can be used for the improvement of the performance and the stability of the distributed generation system. The estimation error is inevitable in the conventional estimation method because of the axis rotation due to PLL. In the conventional estimation error, the d-q voltage and current are used for the calculation of the impedance with active and reactive current injections. Conversely, in the proposed algorithm, the negative sequence current is injected, and then the negative sequence voltage is measured for the impedance estimation. As the positive and negative sequence current controller is independent and the PLL is based on the positive sequence component only, the estimation of the equivalent impedance can be achieved with high accuracy. Simulation and experimental results are compared to validate the proposed algorithm.

Voltage Control Scheme in Synchronous Reference Frame for Improving Dynamic Characteristics in Parallel Operation of Double-Conversion UPSs (이중 변환 UPS 병렬 운전의 제어 동특성 향상을 위한 동기 좌표계 전압 제어기 구조)

  • Mo, Jae-Sing;Yoon, Young-Doo;Ryu, Hyo-Jun;Lee, Min-Sung;Choi, Seung-Cheul;Kim, Sung-Min;Kim, Seok-Min;Kang, Ho-Hyun;Kim, Hee-Jung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2022
  • This study proposes a voltage control scheme in a synchronous reference frame to improve the dynamic characteristics of double-conversion UPSs. UPSs need to control positive and negative sequence voltage, so that positive and negative sequence extractors are generally used to obtain each sequence of the voltage and current. Voltage and current controllers for each sequence are implemented. However, the extractor causes considerable delay, and the delay restricts the control performance, especially for the current controller. To improve the dynamics of the current controller, the proposed scheme adopts a unified current controller without separating positive and negative sequences. By using discrete-time current controller, the control bandwidth can be extended significantly so that negative sequence current can be controlled. To enhance the performance, an additional feed-forward technique for output voltage regulation is proposed. The validity of the proposed controller is verified by experiments.

The Study of Underwater Discharge Characteristics against impulse voltage (임펄스전압에 의한 수중방전특성에 대한 연구)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Feng;Kim, Hoe-Gu;Lee, Kang-Soo;Ahn, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.271-273
    • /
    • 2007
  • This paper presents the experimental results of underwater discharges in 25 mm point-plane gap caused by impulse voltage. Discharge phenomena were observed by digital cameras and recorded by oscilloscope. As a result, discharge patterns in positive and negative polarity have different shapes according to applied voltage amplitudes. The positive discharge is like root but the negative discharge is similar to bush. As the voltage is increased, the discharge routs are thick and have more branches. Also the time to breakdown is inversely proportional to voltage.

  • PDF

The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems (ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정)

  • Kim, Mi-Young;Hara, Ryoichi;Kita, Hiroyuki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

A Low-Voltage Vibrational Energy Harvesting Full-Wave Rectifier using Body-Bias Technique (Body-Bias Technique을 이용한 저전압 진동에너지 하베스팅 전파정류회로)

  • Park, Keun-Yeol;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.425-428
    • /
    • 2017
  • This paper describes a full-wave rectifiers for energy harvesting circuit using a vibrational energy. The designed circuit is applied to the negative voltage converter with the body-bias technique using the Beta-multiplier so that the power efficiency is excellent even at the low voltage, and the comparator is designed as the bulk-driven type. The proposed circuit is designed with $0.35{\mu}m$ CMOS process, and The designed chip occupies $931{\mu}m{\times}785{\mu}m$.

  • PDF

A Negative Curvature effect for breakdown voltage of lateral junction on SOI (SOI 수평형 접합의 항복 전압 향상을 인한 Negative Curvature(NC) 효과)

  • Byun, Dae-Seok;Choi, Yearn-Ik;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.243-245
    • /
    • 1993
  • The negative curvature effect on the breakdown voltage of p-n junction, which may realize 1-D breakdown voltage due to the lower peak electric field at the junction, is proposed and verified by the fabrication of lateral diode on Silicon-on-Insulator (SOI) together with MEDICI simulation. The experimental and simulation results show good agreements with the theoretical expectation. The proposed method is effectively applicable to the lateral, especially on SOI, power devices.

  • PDF

Grid-Connected Inverter Using the Negative Conductance of Photovoltaic Power System (태양광 발전시스템의 네가티브 컨덕턴스를 이용한 계통연계형 인버터)

  • Lee, Chang-Hee;Park, Ki-Lack;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.45-48
    • /
    • 2002
  • This paper proposes a grid-connected inverter using the negative conductance of PV power system, which has four IGBTs and simple controller. Most of modern electric loads generate the current harmonics and the line voltage distortion. The new solar-to-ac converter(STAC) provides by emulating a negative conductance load to the line voltage, so the current harmonics from STAC is canceled the effect of the harmonics from other loads. As a result, the line voltage distortion is decreased. The proposed system have low cost, small size, and light weight compared to conventional photovoltaic converter

  • PDF

Wide viewing angle and fast response time using novel vertical-alignment - 1/4 ${\pi}$ cell mode

  • Lee, Jeong-Ho;Seo, Dae-Shik;Kim, Hyang-Yul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.9-10
    • /
    • 2000
  • The wide viewing angle and fast response time characteristics of negative dielectric anisotropy nematic liquid crystal (NLC) using a novel vertical-alignment (VA) - 1/4 ${\pi}$ cell mode on a homeotropic alignment layer were investigated. Good voltage-transmittance curves and low driving voltage using the novel VA - 1/4 ${\pi}$ cell mode without a negative compensation film were obtained. The iso-viewing angle characteristics of NLC using the novel VA - 1/4 ${\pi}$ cell mode without a negative compensation film can be achieved. The fast response time of 24.4 ms in NLC was successfully measured. The iso-viewing angle, fast response time, and low driving voltage characteristics using the novel VA - 1/4 ${\pi}$ cell mode can be achieved.

  • PDF

Stable Point Setting in Negative-Resistance Multivibrator Designs (부성저항 말티바이브레이터의 안정점 설정과 동작안정성)

  • 임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.2
    • /
    • pp.7-15
    • /
    • 1973
  • The operation behaviors of negative-resistance multivibrators. are described. The oscillation phenomena in monostable and bistable mode negative-resistance circuits are analyzed by using a analog computer. It is presented that voltage-controlled negative -resistance switching circuits may be in oscillation state for a time or parmanently by adding the bias voltage or trigger pulse. The results show that the care must be taken for this fact in the constructions of negative resistance switching circuits.

  • PDF