• 제목/요약/키워드: Needle motion

검색결과 53건 처리시간 0.026초

관절강내 봉약침과 매선요법을 병행한 슬개골 재발성 탈구 증례보고 (A Case Report of Patient with Recurrent Patellar Dislocation Treated by Korean Medicine Treatment in Combination with Intra-articular Bee Venom Injection and Needle-embedding Therapy)

  • 유경곤;김진희;민선정;염승룡;권영달;이지현
    • 한방재활의학과학회지
    • /
    • 제23권4호
    • /
    • pp.251-259
    • /
    • 2013
  • The purpose of this study is to observe the effect of Korean medicine treatment in combination with intra-articular bee venom injection and needle-embedding therapy on recurrent patellar dislocation in patient. The Patient, diagnosed as recurrent patellar dislocation, was treated by Korean medicine treatment in combination with intra-articular bee venom injection and needle-embedding therapy. Visual analogue scale (VAS), knee flexion range of motion (ROM), Korean Western Ontario and Mcmaster Universities arthritis index (K-WOMAC) were used to measure changes during treatment. After treatment, VAS, knee flexion ROM, K-WOMAC were improved significantly. The Korean medicine treatment in combination with intra-articular bee venom injection and needle-embedding therapy was proved to be helpful to improve the symptoms of the recurrent patellar dislocation.

광폭면 분무를 위한 2유체 노즐의 분무 특성에 관한 연구 (An Experimental Study on the Spray Characteristics by Twin-Fluid Atomizer for Wide Band Spray)

  • 이중순
    • 한국분무공학회지
    • /
    • 제13권4호
    • /
    • pp.212-219
    • /
    • 2008
  • To develop the twin-fluid atomizer having the excellent performance of painting, the spray characteristics of how a wide area can be painted efficiently by one time spraying were studied in this paper. Spray phenomena are affected by the many factors determining the spray field such as the spraying pressure of gas, the spraying pressure and viscosity of liquid paints, the opening duration of needle valve, the design dimension of nozzle, and so on. As the results of experiments, these factors affecting on spray characteristics were suggested as followings; 1) The optimum spraying pressure of gas was $0.015{\sim}0.02\;kPa$, and the appropriate spraying pressure of liquid paint was 0.01kPa, In these situations, the setting up pressures must be compensated as much as the losing amount of pressure because a decompression occurred when operating valves. 2) The duration of opening the needle valve must be sustained for $1{\sim}2$ seconds to inject gas after spraying the liquid paint. This operating of the needle valve was necessary to avoid the affect on the changing of liquid column length, and to prevent the droplet deposit at the initial time of spraying. 3) The spray tip penetration was gained form the experimental equation, and the effective spraying angle was $85^{\circ}{\pm}5^{\circ}$ just at he appropriate spraying pressure of gas. The distribution of the area sprayed had the variation in $350{\pm}50\;mm$ because of the spraying pressure of gas, the its distance from the spray tip, and the lift of the needle valve.

  • PDF

유체법을 이용한 코로나 방전의 1차원 수치해석 (1-Dimensional Simulation of the Corona Discharge using Fluid Method)

  • 이용신;심재학;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

침자 수기법 교육 시스템 개발 (Development of Acupuncture Manipulation Education System)

  • 임진웅;정원모;이인선;서윤정;류호선;류연희;채윤병
    • Journal of Acupuncture Research
    • /
    • 제31권4호
    • /
    • pp.11-19
    • /
    • 2014
  • Objectives : Acupuncture manipulation, a kind of sophisticated hand movements, has been considered a fundamental skill for acupuncture practice. In this study, we aimed to develop acupuncture manipulation education system(AMES) using visual feedback of acupuncture manipulation. We also investigated whether or not acupuncture practice-$na{\ddot{i}}ve$ students could enhance their acupuncture manipulation skills after AMES training. Methods : Using AMES and motion sensor, we visualized a time-series motion template(intended motion) and participant's own motion(actual motion) manipulating an acupuncture needle. Ten students were trained with complex lifting/thrusting techniques for 8 training trials. We compared the motion pattern error of the students between the first and the last trials. Results : In our pilot experiment, half of the participants showed significantly improved manipulation skills in complex lifting/thrusting techniques after training with AMES which is developed in this study, while the other half of the participants did not show significant improvements. Conclusions : The AMES could be useful in acupuncture-manipulation training for students. Our findings suggest that novice can improve sophisticated hand movement for acupuncture manipulation with sensorimotor learning using visual feedback.

Ferroelastic Domain Wall Motions in Lead Zirconate Titanate Under Compressive Stress Observed by Piezoresponse Force Microscopy

  • Kim, Kwanlae
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.546-550
    • /
    • 2017
  • Ferroelectric properties are governed by domain structures and domain wall motions, so it is of significance to understand domain evolution processes under mechanical stress. In the present study, in situ piezoresponse force microscopy (PFM) observation under compressive stress was carried out for a near-morphotropic PZT. Both $180^{\circ}$ and $non-180^{\circ}$ domain structures were observed from PFM images, and their habit planes were identified using electron backscatter diffraction in conjunction with PFM data. By externally applied mechanical stress, needle-like $non-180^{\circ}$ domain patterns were broadened via domain wall motions. This was interpreted via phenomenological approach such that the total energy minimization can be achieved by domain wall motion rather than domain nucleation mainly due to the local gradient energy. Meanwhile, no motion was observed from curvy $180^{\circ}$ domain walls under the mechanical stress, validating that $180^{\circ}$ domain walls are not directly influenced by mechanical stress.

산업용 자동 재봉기 제어장치 개발에 관한 연구 (A study on the development of automatic sewing machine)

  • 김종찬;라승호;이응혁;허경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.281-285
    • /
    • 1990
  • Our N.C. sewing machine is a device that acts sewing automatically in reference to N.C. data made by data input device. Our N.C. sewing mechine is composed of induction motor that has electric clutch and brake, step motor that drives x-y table. Sewing area of our machine is 170 mm * 100 mm, maximum sewing speed is about 2000 spm, maximum stitch length 6.2 mm. In actual sewing, synchronization between motion of needle up-down and motion of x-y table is a critical factor. In this paper, technology about synchronization will be profoundly discussed.

  • PDF

지배 모션 분석을 통한 영상 안정 방법에 관한 연구 (An Image Stabilization by Dominant Motion Analysis)

  • 김희정;차용준;소영성
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 추계종합학술대회논문집
    • /
    • pp.113-116
    • /
    • 2000
  • 본 논문에서는 카메라 또는 카메라 플랫폼의 흔들림 등의 외부 영향과 비디오 시퀸스내의 모션이 함께 있을 경우의 출렁이는 비디오를 전자적으로 안정화시키는 방법을 제안한다. 일반적인 영상 안정 시스템은 모션 측정과 모션 보상의 두과정으로 구성되어 있다. 모션 측정에서 프레임간 모션 모델을 가정하고 모션 파라메타를 측정한다. 모션 보상에서는 측정된 파라메타를 이용하여 현재 영상 좌표계를 기준 영상 좌표계로 변환하고 명암값 보간을 하여 영상안정을 이루어 낸다. 그러나 상기의 방법으로는 카메라 움직임외에 다른 모션 요소가 있을 때 어려움을 겪게 된다 이의 해결을 위해 motion vector scatter diagram(MVSD)에 기반한 지배 모션 측정 방법을 제안한다 이 방법은 영상을 일정영역의 subblock으로 나눈후 각 subblock의 중심을 특징점으로 잡아 correlation 과정을 거쳐 영상간의 모션 벡터를 구한 다음 구해진 모션 벡터로 needle diagram과 MVSD를 구축한다. 구축한 MVSD의 패턴은 모션의 종류에 따라 일정한 모양을 갖게 되는데 이의 분석을 위해 목적함수를 정의하고 피 함수의 최적화를 통해 지배 모션 파라메타를 측정한 후 그 파라메타로 모션 보상을 함으로서 영상안정을 이룰 수 있다.

  • PDF

공동현상을 고려한 커먼레일용 고압 DME 인젝터 노즐의 최적 설계 연구 (Study on the Optimum Design of High Pressure Common-rail DME Injector Nozzle with Consideration of Cavitation)

  • 정수진;박정권;이상인
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.99-106
    • /
    • 2013
  • DME (Di-Methyl Ether) is synthetic product that is produced through dehydration of methanol or a direct synthesis from syngas. And it is able to save fossil fuel and reduce pollutants of emission such as PM and $CO_2$. In spite of its advantages it is difficult to design DME fuelled engine system because DME fuel may cause to severely generate cavitation and corrosion in fuel delivery system due to physical properties of DME. Therefore, in this study three-dimensional internal flow characteristics with consideration of cavitation were predicted in the DME injector using diesel and DME fuel. Moving grid technique was employed to describe needle motion and 1-D hydraulic simulation of injector was also simulated to obtain transient needle motion profiles. The results of simulation show that cavitations was generated at the inlet of nozzle near high velocity region both diesel and DME. And mass flow rate of DME is reduced by 4.73% compared to that of diesel at maximum valve lift because cavitation region of DME is much more larger. To increase flow rate of DME injector, internal flow simulation has been conducted to investigate the nozzle hole inner R-cut effect. The flow rates of diesel and DME increase as R-cut increases, and flow coefficient of DME fuel injector was increased by 6.3% on average compared with diesel fuelled injector. Finally, optimum shape of DME injector nozzle is suggested through the comparison of flow coefficient with variation of nozzle hole inner R-cut.

흡입 후 견 봉합사 거치를 통한 만성 족관절 외과 점액낭염의 치료 (The Effect of Indwelling Silk Suture Following Aspiration in the Treatment of Chronic Lateral Malleolar Bursitis)

  • 이봉진;이성락;김성태
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2005
  • Purpose: To evaluate the drainage effect of silk suture following aspiration of the bursa as an early treatment of chronic lateral malleolar bursitis. Materials and Methods: Thirteen cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 16.4 months. The average symptom duration before introduction into this study was 7.8 weeks. With an aseptic technique, the aspiration of the bursa was done with 18G needle and syringe and then the insertion of silk suture through the aspiration needle was performed. The amount of drainage was identified two or three times in a week and stitch out was done at the cessation of drainage. Over one year follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Results: Redness around the insertion site of silk suture was found in all cases, but there was no development of active infection or recurrence. The average duration of treatment is 10.4 days. Conclusion: The drainage with silk suture following aspiration of the bursa is less invasive and very effective method in the early treatment of chronic lateral malleolar bursitis.

  • PDF

흡입 후 견 봉합사 거치를 통한 만성 주두 점액낭염의 치료 (The Effect of Indwelling Silk Suture Following Aspiration in the Treatment of Chronic Olecranon Bursitis)

  • 이봉진;이성락;김성태
    • Clinics in Shoulder and Elbow
    • /
    • 제8권1호
    • /
    • pp.31-35
    • /
    • 2005
  • The purpose of this study was to evaluate the drainage effect of silk suture following aspiration of the bursa as an early treatment of chronic olecranon bursitis. Eleven cases, which have over two weeks of history and over one year of follow-up, were investigated. The average duration of follow-up was 17.5 months. The average symptom duration was 1.8 months. With an aseptic technique, the aspiration of the bursa was done with 18gauge needle and syringe and then the insertion of silk suture through the aspiration needle was performed. The amount of drainage was regularly checked $2{\sim}3$ days interval and stitch out was done at the cessation of drainage. At the follow-up, recurrence, infection, pain, and limitation of range of motion were investigated by telephone interview. Redness around the insertion site of silk suture was found in all cases, but there was no active infection or recurrence. The results were satisfactory in all cases and the average time for recovery was 10.5 days. The drainage with silk suture following aspiration of the bursa is less invasive and very effective method in the early treatment of chronic olecranon bursitis.