• Title/Summary/Keyword: Neck fracture

Search Result 241, Processing Time 0.025 seconds

Fracture and dislocation of the four lateral metatarsophalangeal joints - A case report (외측 4개 중족 족지 관절의 골절-탈구 - 증례보고 -)

  • Yim, Soo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2000
  • Fracture and dislocation of the four lateral metatarsal head and neck at the metatarsophalangeal joint, which may be associated with a hyperextension force, axial load, and additional rotating force, has rarely been reported. The patient was a 32-year-old man who sustained the injury in a motor vehicle accident. Manual reduction was easily performed but maintenance of reduction was difficult, due to the associated fractures of the metatarsal necks. Thus percutaneous internal fixation with Kirshner's wires was required.

  • PDF

Usefulness of Fracture Risk Assessment Tool Using Lumbar Bone Mineral Density in Prediction of Osteoporotic Vertebral Fracture

  • Lee, Heui Seung;Lee, Sang Hyung;Chung, Young Seob;Yang, Hee-Jin;Son, Young-Je;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.346-349
    • /
    • 2015
  • Objective : To investigate the value of lumbar bone mineral density (BMD) in fracture risk assessment (FRAX) tool. Methods : One hundred and ten patients aged over 60 years were enrolled and divided into 2 groups as non-osteoporotic vertebral fracture (OVF) and OVF groups. The 10-year-risk of major osteoporotic vertebral fracture of each group was calculated by FRAX tool with femoral and lumbar spine BMDs to compare the usefulness of lumbar spine BMD in prediction of OVF. The blood level of osteocalcin and C-terminal telopeptide (CTX) as markers of activities of osteoblast and osteoclast, respectively were analyzed using the institutional database. Results : In the OVF group, the ratio of patients with previous fracture history or use of glucocorticoid was higher than those in non-OVF group (p=0.000 and 0.030, respectively). The levels of T-score of femur neck and lumbar spine in OVF group were significantly lower than those in non-OVF group (p=0.001 and 0.000, respectively). The risk of OVF in FRAX using femur BMD in non-OVF and OVF groups was $6.7{\pm}6.13$ and $11.4{\pm}10.06$, respectively (p=0.007). The risk of using lumbar BMD in the 2 groups was $6.9{\pm}8.91$ and $15.1{\pm}15.08$, respectively (p=0.002). The areas under the receiver operator characteristic curve in the FRAX risk with lumbar and femur neck BMD were 0.726 and 0.684, respectively. The comparison of osteocalcin and CTX was not significant (p=0.162 and 0.369, respectively). Conclusion : In our study, the 10-year risk of major osteoporotic fracture in the OVF group of our study was lower than the recommended threshold of intervention for osteoporosis. Hence, a lower threshold for the treatment of osteoporosis may be set for the Korean population to prevent OVF. In the prediction of symptomatic OVF, FRAX tool using lumbar spine BMD may be more useful than that using femur neck BMD.

A Case of Oncocytic Carcinoma Arising in the Submandibular Gland (악하선에 발생한 호산성 세포암종 1예)

  • Shin, Seung-Kuk;Lee, Young-Ok;Lee, Byung-Joo;Lim, Yun-Sung
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.55 no.3
    • /
    • pp.173-176
    • /
    • 2012
  • Oncocytic neoplasm of the head and neck region accounts for approximately 1% of all salivary gland tumors, but only 5% of oncocytic neoplasm is malignant. Oncocytic carcinoma arising in the submandibular gland is exceedingly rare. We encountered a sixty seven-year-old male patient who presented with multiple mass in the right neck. Fine needle aspiration biopsy revealed a salivary gland tumor of predominantly oncocytic form, and a differential diagnosis included oncocytic adenoma or mucoepidermoid carcinoma. A right submandibular gland resection and modified radical neck dissection were performed. Histologically, the tumor cells showed nuclear pleomorphism, and stromal invasion, which were compatible with oncocytic carcinoma. After surgery, the entire neck region was irradiated. Seventeen months after the initial surgery, multiple metastases to the bone and lung were detected from the incidental pathologic bone fracture of the right humerus; palliative chemotherapy was performed to resolve this. We report a case of oncocytic carcinoma in the submandibular gland with a review of literature.

Fracture Analysis of Hole Flanging Process for High Strength Steel Sheets (고강도 열연판재의 홀 플랜정시 파단특성연구)

  • 김정운;김봉준;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.6
    • /
    • pp.465-470
    • /
    • 2001
  • Hole flanging experiments are performed on flat circular plates with a hole in the center and the flangeability and fracture behaviors of TRIP steels and ferrite-Bainite duplex steels were examined. In the hole flanging, deformation by lip and petalling occurs when plates are struck by punches of various shapes and high circumferential strains induced in the target material cause radial cracking and the subsequent rotation of the affected plate material in a number of symmetric petals. In all cases, failure of the plate was due to lip fracture that results from multiple localized neckings that take place around the hole periphery where straining is most severe and a somewhat regular pattern was observed in a fracture shape. The neck characteristics in flange formation and the transition from the lip to petal mode at which fracture occurs were compared with two materials.

  • PDF

Surgical Treatment of Ipsilateral Multi-Level Femoral Fracture Treated Using Antegrade Intramedullary Nail

  • Kim, Beom-Soo;Cho, Jae-Woo;Yeo, Do-Hyun;Oh, Jong-Keon
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2018
  • Ipsilateral fractures of proximal femur with shaft and condylar region are very rare. Current concept of management is based on fixation of each fracture as independent entity using separate fixation modalities for proximal and distal parts of femur. However, we considered that antegrade femoral nailing with cephalomedullary screw fixation is a good option for ipsilateral multi-level femoral fractures. Here, we present an experience of satisfactory treatment for ipsilateral femoral neck fracture, subtrochanteric fracture, comminuted shaft fracture with supracondylar fracture following road traffic accident.

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

Influence of neck width on the performance of ADAS device with diamond-shaped hole plates

  • Wu, Yingxiong;Lu, Jianfeng;Chen, Yun
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.19-32
    • /
    • 2020
  • Metallic energy-dissipation dampers are widely used in structures. They are comprised of an added damping and stiffness (ADAS) device with many parallel, diamond-shaped hole plates, the neck width of which is an important parameter. However, no studies have analyzed the neck width's influence on the ADAS device's performance. This study aims to better understand that influence by conducting a pseudo-static test on ADAS, with three different neck widths, and performing finite element analysis (FEA) models. Based on the FEA results and mechanical theory, a design neck width range was proposed. The results showed that when the neck width was within the specified range, the diamond-shaped hole plate achieved an ideal yield state with minimal stress concentration, where the ADAS had an optimal energy dissipation performance and the brittle shear fracture on the neck was avoided. The theoretical values of the ADAS yield loads were in good agreement with the test values. While the theoretical value of the elastic stiffness was lower than the test value, the discrepancy could be reduced with the proposed modified coefficient.

Comparative Study for Osteosynthesis of Femoral Neck Fractures: Cannulated Screws versus Femoral Neck System

  • Youngho Cho;Jae-uk Shin;Sangwoo Kim
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.47-53
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the radiological results of fixation using the femoral neck system (FNS) and cannulated screw (CS) for treatment of femoral neck fractures. Materials and Methods: A retrospective study of patients with femoral neck fractures who underwent internal fixation and had follow-up of more than six months from 2010 to 2020 was conducted. A total of 87 patients were enrolled in the study. The FNS group included 20 patients and the CS group included 67 patients. Classification of fractures was performed according to Garden and Pauwels classification. Operation time, intraoperative blood loss, sliding distance of the implant, lateral soft tissue irritation caused by implants, and complications were evaluated. Results: The mean operation time was 40.30 minutes in the FNS group and 46.84 minutes in the CS group. The mean intraoperative bleeding volume was 51.25 mL in the FNS group and 72.16 mL in the CS group. Bone union was achieved in 18 patients in the FNS group (90.0%) and in 61 patients in the CS group (91.0%). The mean sliding distance of the implant was 4.06 mm in the FNS group and 3.92 mm in the CS group. No patients in the FNS group and 12 patients in the CS group complained of soft tissue irritation. Conclusion: A shorter operative time, less intraoperative bleeding, and less irritation of soft tissue were observed in the FNS group. FNS could be an alternative to CS for fixation of femoral neck fractures.

Modified Extracorporeal Reduction of the Mandibular Condylar Neck Fracture

  • Kim, Min-Keun;Kwon, Kwang-Jun;Kim, Seong-Gon;Park, Young-Wook;Kim, Jwa-Young;Kweon, Hae-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.1
    • /
    • pp.30-36
    • /
    • 2014
  • There are many treatment options in management of mandibular condylar neck fractures. Closed reduction is the most conservative treatment; however, achievement of anatomic reduction is difficult, and there are some risks of mandibular functional impairment. Open anatomic reduction and internal fixation have some advantages; therefore, many oral and maxillofacial surgeons have attempted to achieve anatomic reduction through the open approach and extracorporeal reduction and fixation. However, when using this method, there is some risk of resorption of the fractured mandibular condylar head. Therefore, we designed a modified extracorporeal reduction technique, without detaching the lateral pterygoid muscle in order to maintain the blood supply to the fractured mandibular condylar head. We believe that this minor modification may minimize the risk of resorption of the fractured mandibular condylar head. In this article, we introduce this technique in detail, and report on two cases.

Risk Factors of the 2-Year Mortality after Bipolar Hemiarthroplasty for Displaced Femoral Neck Fracture

  • Jung Wook Huh;Han Eol Seo;Dong Ha Lee;Jae Heung Yoo
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.164-174
    • /
    • 2023
  • Purpose: This study investigates the relationship between preoperative neutrophil-to-lymphocyte ratio (NLR), lymphocyte-to-C-reactive protein ratio (LCR), albumin, and 2-year mortality in elderly patients having hemiarthroplasty for displaced femoral neck fracture (FNF). Materials and Methods: We retrospectively reviewed 284 elderly patients who underwent hemiarthroplasty for Garden type IV FNF from September 2014 to September 2020. Using the receiver operating characteristic curve, optimal cutoff values for LCR, NLR, and albumin were established, and patients were categorized as low or high. Associations with 2-year mortality were evaluated through univariate and multivariate Cox regression analyses. Results: Of the 284 patients, 124 patients (45.9%) died within 2 years post-surgery. The optimal cutoff values were: LCR at 7.758 (specificity 58.5%, sensitivity 25.0%), NLR at 3.854 (specificity 39.2%, sensitivity 40.0%), and albumin at 3.750 (specificity 65.9%, sensitivity 21.9%). Patients with low LCR (<7.758), high NLR (≥3.854), and low albumin (<3.750) had a statistically significant reduced survival time compared to their counterparts. Conclusion: Lower preoperative LCR and albumin levels, along with higher NLR, effectively predict 2-year mortality and 30-day post-surgery complications in elderly patients with Garden type IV FNF undergoing hemiarthroplasty.