• 제목/요약/키워드: Near-Field Resonator

검색결과 23건 처리시간 0.024초

근접장 마이크로파 현미경을 이용한 Copper(II)-phthalocyanine 박막의 특성 연구 (Characterization of thin film properties of Copper(II)-Phthalocyanine using a near-field scanning microwave microscope)

  • 박미화;이기진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.460-463
    • /
    • 2003
  • We report the microwave reflection coefficient $S_{11}$ of copper(II)-phthalocyanine(CuPc) using a near-field microwave microscope(NSMM) in order to understand the intrinsic electromagnetic properties of organic materials. For a NSMM system, a high-quility microstip resonator coupled with a dielectric resonator was used. The reflection coefficient $S_{11}$ was changed by the preparation conditions of CuPc thin films. We compared the reflection coefficient with crystal phase, surface morphology, UV absorption spectra and x-ray diffraction results.

  • PDF

발진기의 2채배 고조파 주파수 천이를 이용한 생체신호 측정센서 (Vital Sign Sensor Based on Second Harmonic Frequency Drift of Oscillator)

  • 구기영;홍윤석;이희조;윤기호;육종관;김강욱
    • 한국전자파학회논문지
    • /
    • 제27권3호
    • /
    • pp.299-306
    • /
    • 2016
  • 본 논문에서는 공진기와 인체와의 거리에 따른 근접 전자기장 변화에 의한 공진기 임피던스의 변화를 토대로 사람의 호흡 및 심박신호를 검출할 수 있는 센서를 제안한다. 제안된 생체신호 측정센서는 패치형 공진기가 결합된 발진기, 발진주파수의 2채배 주파수만 통과시키기 위한 다이플렉서, 증폭기, SAW 필터 및 RF 검출기로 구성되어 있다. 호흡과 심박신호와 같은 인체의 주기적인 움직임은 근접 전자기장 영역 안에서 공진기의 임피던스 변화를 야기하며, 발진기의 주파수를 변화시킨다. 감도를 향상시키기 위해 발진주파수의 2채배 주파수 천이를 SAW 필터의 저지대역에 위치시킴으로써, 제안된 센서의 검출 거리를 2배로 확장시킬 수 있다. 제안된 센서의 측정결과, 최대 40 mm까지 호흡 및 심박신호가 안정적으로 측정되는 것을 확인하였다.

근접장 마이크로파 현미경을 이용한 Copper(II)-phthalocyanine의 Phase Transition 연구 (Study of Phase Transition of Copper(II)-phthalocyanine using a Near Field Scanning Microwave Microscope)

  • 박미화;유현준;윤순일;임은주;이기진;차덕준;이용산
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.641-646
    • /
    • 2004
  • We report the changes of the microwave reflection coefficients S$_{11}$ of copper(II)-phthalocyanine (CuPc) thin films by using a near-field microwave microscope(NSMM) in order to understand the phase transition of CuPc. For a NSMM system, a high-quality microstrip resonator coupled with a dielectric resonator was used. CuPc thin films were prepared on the pre-heated glass substrates using a thermal evaporation method. The reflection coefficients S$_{11}$ of CuPc thin films were changed by the dependence on the substrate pre-heating temperatures. By comparing reflection coefficient S$_{11}$ and crystal structures, we found the phase transition of CuPc thin films from $\alpha$-phase to $\beta$-phase at the substrate heating temperature 200 $^{\circ}C$./TEX>.

Wireless RF Sensor Structure for Non-Contact Vital Sign Monitoring

  • Kim, Sang-Gyu;Yun, Gi-Ho;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제12권1호
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes a compact and novel wireless vital sign sensor at 2.4 GHz that can detect heartbeat and respiration signals. The oscillator circuit incorporates a planar resonator, which functions as a series feedback element as well as a near-field radiator. The periodic movement of a human body during aerobic exercise could cause an input impedance variation of the radiator within near-field range. This variation results in a corresponding change in the oscillation frequency and this change has been utilized for the sensing of human vital signs. In addition, a surface acoustic wave (SAW) filter and power detector have been used to increase the system sensitivity and to transform the frequency variation into a voltage waveform. The experimental results show that the proposed sensor placed 20 mm away from a human body can detect the vital signs very accurately.

비접촉 근접장 마이크로파 현미경을 이용한 NaCl 용액의 농도 측정 (Concentration of Sodium Chloride Solutions Sensing by Using a Near-Field Microwave Microprobe)

  • 김송희;윤영운;;김종철;이기진
    • 비파괴검사학회지
    • /
    • 제27권1호
    • /
    • pp.23-30
    • /
    • 2007
  • 본 연구에서는 근접장 마이크로파 현미경을 이용하여 NaCl 용액의 농도검출센서로의 응용 가능성에 대해 알아보았다. 근접장 마이크로파 현미경은 높은 Q 인자를 갖는 유전체 공진기를 이용하여 고감도 특성을 갖는다. 측정과정에저 탐침이 액체 시료표면에 근접했을 때 발생할 수 있는 표면장력의 영향을 피하기 위해 튜닝폭 피드백시스템을 이용하여 탐침과 시료 사이의 거리를 $1{\mu}m$로 유지하였다. 측정은 4GHz에서 이루어졌으며 NaCl 용액의 농도 변화, 농도 및 온도 변화, 부피 변화에 따른 마이크로파 반사계수($S_{11}$)을 관측하여 농도를 측정하였다. 또한 선택적 반응 감도 특성을 알아보기 위하여 NaCl과 글루코스의 혼합용액에서 글루코스의 농도 및 NaCl 용액의 농도를 관측하였다.

도파관 공진기를 이용한 마이크로파 근접장 현미경의 특성에 관한 연구 (A Study on Properties of a Near-Field Microwave Microscope Using a Waveguide Resonator)

  • 김현;김송희;김주영;이기진
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.16-24
    • /
    • 2008
  • 섭동이론인 형태 섭동과 물질 섭동을 적용하여 도파관 공진기를 사용한 마이크로파 근접장 현미경의 특성에 대해 연구하였다. 먼저, Ansoft사의 HFSS (high frequency structure simulator)를 사용하여 공진기 내부의 모드해석과 함께 공진기에서 선형 및 고리형 탐침에 대해 전력전달이 최대가 되고 탐침의 감도 향상을 기대할 수 있는 위치를 확인하였다. 더불어, 유전율이 서로 다른 유전체 시료 (teflon, glass, $Al_2Q_3,\;LaAlO_3,\;SrTiO_3$)에 대해 마이크로파 반사계수$(S_{11})$를 측정하였다. 측정결과로부터 유전율이 증가함에 따라 마이크로파 반사계수$(S_{11})$는 증가하고 공진주파수는 감소하였다. 이를 통해, 도파관 공진기를 이용한 마이크로파 근접장 현미경에서 선형 및 고리형 탐침의 위치에 따른 공진기의 감도 및 공진특성에 대해 알아보았다.

New Classes of LC Resonators for Magnetic Sensor Device Using a Glass-Coated Amorphous CO83.2B3.3Si5.9Mn7.6 Microwire

  • Kim, Yong-Seok;Yu, Seong-Cho;Hwang, Myung-Joo;Lee, Hee-Bok
    • Journal of Magnetics
    • /
    • 제10권3호
    • /
    • pp.122-127
    • /
    • 2005
  • New classes of LC resonators for micro magnetic sensor device were proposed and fabricated. The first type LC resonator (Type I) consists of a small piece of microwire and two cylindrical electrodes at the end of the microwire without direct contact to its ferromagnetic core. In type I resonator the ferromagnetic core of the microwire and cylindrical electrodes act as an inductor and two capacitors respectively to form a LC circuit. The second type LC resonator (Type II) consists of a solenoidal micro-inductor with a bundle of soft magnetic microwires as a core. The solenoidal micro-inductors fabricated by MEMS technique were $500\sim1,000\;\mu{m}$ in length with $10\sim20$ turns. A capacitor is connected in parallel to the micro-inductor to form a LC circuit. A tiny glass coated $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire was fabricated by a glass-coated melt spinning technique. A supergiant magneto-impedance effect was found in a type I resonator as much as 400,000% by precise tuning frequency at around 518.51 MHz. In type II resonator the changes of inductance as a function of external magnetic field in micro-inductors with properly annealed microwire cores were varied as much as 370%. The phase angle between current and voltage was also strongly dependent on the magnetic field. The drastic increments of magnetoimpedance at near the resonance frequency were observed in both types of LC resonators. Accordingly, the sudden change of the phase angle, as large as $180^{\circ}C$, evidenced the occurrence of the resonance at a given external magnetic field.

Magneetoelastic Resonators에 사용되는 새로운 비정질 함금 (Devised New Amorphous Alloys for Magneetoelastic Resonators)

  • 김창경;유충근; R.C. O'Handley
    • 한국표면공학회지
    • /
    • 제31권5호
    • /
    • pp.245-250
    • /
    • 1998
  • There is clear pressing need to reduce bias field(Ha,) used on linear magenetomechanical resonator tag by at least a factor of two to allow low-bias operation near the frequency minimum since reducing Ha causes a dramatic increase in well depth, which implies increased stability. However, this makes it more difficult to maintain tight frequncy specs. It can be solved by a reduction of magnetomechanical coupling(k). We determined from an equivalent circuit model that optimal reduced, k, is near 0.3 Also, We determiend the material properties($lambda_s$, :saturated magenetostriction, $M_s$, and,$H_a$) that give k=0.3. From these evaluations, we suggested that on optimal comosition with adequate mathrial properties is $Fe_{55}Co_{15}Cr_6Nb_2B_{18}Si_4$.

  • PDF

Aperture-Miniaturized Antenna Loaded with Split Ring Resonator Array

  • Oh, Soon-Soo;Park, Wook-Ki;Kang, Suk-Youb;Park, Hyo-Dal
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.315-317
    • /
    • 2009
  • In this letter, a novel antenna with a miniaturized aperture is proposed. The substrate including a split-ring resonator array is inserted into a size-reduced open-ended waveguide. For a low return loss and high radiation efficiency, the ring arrangement is optimized, and a stepped transition using H-plane discontinuity is proposed. The proposed antenna achieves a 70% aperture reduction compared to a conventional standard waveguide antenna of WR-187 (47.6 mm${\times}$22.2 mm). The return loss drops significantly at three frequencies, and a reasonable gain is achieved. The aperture-miniaturized antenna can be used in many antenna applications such as near-field measurement.

  • PDF

Open-Ended Waveguide Antenna Using a Single Split-Ring Resonator

  • Ju, Young-Rim;Oh, Soon-Soo;Park, Wook-Ki;Park, Hyo-Dal
    • ETRI Journal
    • /
    • 제33권2호
    • /
    • pp.291-294
    • /
    • 2011
  • This letter proposes an open-ended waveguide antenna with a single split-ring resonator. In contrast to the waveguide antennas incorporating multiple rings reported in a previous study, which exhibited narrow bandwidth, the proposed antenna uses only one ring to achieve broader bandwidth while keeping the aperture small. A single ring has a relatively low quality factor compared to multiple rings. The simulated and measured fractional bandwidth was 4.13% and 4.03%, respectively, which is much broader than the fractional bandwidth of about 1% demonstrated in a previous study. This simple technique can be used in many applications that require small apertures including near-field probes and array elements.