• Title/Summary/Keyword: Near Field Measurements

Search Result 268, Processing Time 0.026 seconds

GLOBAL MAPPING OF NEAR-EARTH MAGNETIC FIELDS MEASURED BY KITSAT-1 AND KITSAT-2 (KITSAT-1과 KITSAT-2에서 관측한 지구자기장의 분포)

  • 표유선;이동훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.81-92
    • /
    • 1994
  • The magnetic field measurements from the KitSat-1 and KitSat-2 were tested by comparing with the IGRF model. The magnetic data have been collected by a three-axis fluxgate magnetometer on each satellite at an latitude of 1,325 km and 820 km, respectively. To avoid highly variable magnetic disturbances at the polar region, the field map has been within the limits of 50 degrees in latitude. Each data is averaged over the square of $5{\times}5$ degrees in both latitude and longitude. In these results, the relatively quiet periods were selected and the sampling rate was 30 seconds. It is shown that the results from these measurements are consistent with the IGRF map over the global surface map.

  • PDF

New Experimental Investigation of Magnetic and Electric Fields in the Vicinity of High-Voltage Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.102-109
    • /
    • 2016
  • In this paper, the theoretical and experimental characteristics of magnetic and electric fields in the vicinity of high voltage lines are investigated. To realize these measurements and calculations, we have developed some equations for two overhead power line configurations of 150 kV (single circuit, double circuit), based on Biot-savart law, image and Maxwell theories, in order to calculate the magnetic and electric fields. The measurements were done to a maximum distance from the tower of 50 m, at a height of 1m from the ground. These experiments take into consideration the real situations of the power lines and associated equipment. The experimental results obtained are near to that of the Biot-Savart theoretical results for a far distance from the tower; and for a distance close to the power line, the results from the image theory are in good agreement with the experimental results.

Dynamic Response and Carrier Velocity in Organic Field-Effect Transistors

  • Cobb, Brian;Wang, Liang;Dunn, Lawrence;Dodabalapur, Ananth
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.60-63
    • /
    • 2009
  • In this letter we report on the carrier velocity of polycrystalline pentacene transistors as a function of electric field. We performed a series of measurements on devices with a range of channel lengths. At moderate electric fields (<$5{\times}10^5$ V/cm), the characteristics are similar to those of disordered or amorphous organic semiconductors. The highest velocities we have measured are near $6{\times}10^4$ cm/s at room temperature. We perform quasi-static and dynamic measurements to measure carrier velocity. These results fill an important void between experimental results that have been obtained with disordered/amorphous organic semiconductors and single crystals.

  • PDF

Simultaneous Measurements of Temperature and Velocity Fields of a Buoyant Jet Using LIE and PIV Techniques (LIE와 PIV 기법을 이용한 부력제트의 온도장과 속도장 동시측정)

  • Kim Seok;Jang Young Gil;Lee Sang Joon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.513-516
    • /
    • 2002
  • The flow structure and heat transfer characteristics of a turbulent buoyant jet were investigated experimentally. The instantaneous temperature and velocity fields in the near field were measured using a two-frame PIV and PLIF techniques. A thin light sheet illuminated a two-dimensional cross section of the buoyant jet in which Rhodamine B was added as a fluorescent dye. The intensity variations of LIF signal from Rhodamine B molecules scattered by the laser light were captured by a CCD camera after passing an optical filter. By ensemble averaging the instantaneous temperature and velocity fields, the mean temperature and velocity fields as well as the spatial distributions of turbulent statistics were obtained. The results show the flow structure and convective heat transfer of the developing shear layer in the near field.

  • PDF

Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower (송전철탑 주변에서 전장과 자장의 측정과 분석)

  • Lee, B.H.;Gil, H.J.;Ahn, C.H.;Lee, K.O.;Park, T.W.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

Velocity Field Measurements of a Vertical Turbulent Buoyant Jet Using a PIV Technique (PIV 기법을 이용한 비등온 부력제트의 유동구조에 관한 연구)

  • Sin, Dae-Sik;Yun, Jeong-Hwan;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.611-618
    • /
    • 2001
  • The flow characteristics of a turbulent buoyant jet were experimentally investigated using a single-frame PIV system. The Reynolds number based on the nozzle exit velocity and nozzle diameter was about Re=5$\times$10$^3$. The instantaneous velocity fields in the streamwise plane passing the jet axis were measured in the near field X/D <11 with and without the temperature gradient. By ensemble averaging the instantaneous velocity fields, the spatial distributions of mean velocity, vorticity, and higher-order statistics up to third order were obtained. The temperature difference of 10$\^{C}$ does not affect a significant influence to the flow structure in the near field, but the total entrainment rate is increased slightly. The entrainment rate shows a linear variation with the streamwise distance in the region after X/D=5.0.

A Study on Initial and Near-Field Dilution at the Ocean Outfall of Masan-Changwon Municipal Wastewater Treatment Plant (마산ㆍ창원 하수종말 처리장의 해양방류 처리수에 대한 초기ㆍ근역 희석연구(I))

  • Kang See-Whan;You Sung-Hyup;Oh Byung-Cheol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.60-69
    • /
    • 1999
  • In this paper, we have obtained the initial and near-field dilution rates of wastewaters discharged from the ocean outfall of Masan-Changwon municipal wastewater treatment plant from both of field measurements and CORMIX model simulations. In the summer of 1998, water temperature and salinity profiles was measured at 16 stations in the vicinity of the Masan outfall and the dilution rates were analyzed by salinity deficit method. The transport of the wastefields and their initial dilution rates were calculated by CORMIX model using field data as model input. Both of observed and predicted results are shown In very low dilutions with the range of 32~48 from the field data analysis and 29~43 from the model prediction, respectively. This indicates that the water quality in the Masan outfall area can be worsening due to the low dilution rates of diswastewaters, especially, when the ambient currents are very weak in a neap tide and ambient water density is highly stratified in summer.

  • PDF

Near-field limit in positioning the microphone for pressure measurements in using the near-field acoustical holography (근접 음향 홀로그래피에서 음압 측정용 마이크로폰의 근접 거리 한계)

  • Kang, Sung-Chon;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.731-736
    • /
    • 2000
  • The recently developed BEM-based NAH(nearfield acoustical holography) is a useful technique for identifying the sound source of vibrating objects. The acoustic parameters of a sound source can be reconstructed by using the vibro-acoustic transfer matrix, which is determined by means of BEM, and the sound pressure measured in the nearfield. Theoretically, one can come up with a very nice reconstructed result as the field plane gets near to the source surface. However, when a microphone is placed in the very close nearfield of the source surface, the scattering, reflection, or resonance in the gap between the source and the microphone can distort the acoustic field, and therefore, the measured field pressure would differ from the actual one in the absence of the microphone. In order to analyze this problem, the interference effect of the microphone is numerically calculated by using the nonsingular BEM that yields very small error in the nearfield. From this analysis, it is found that the prediction error of the field pressure decreases firstly and then increases as the microphone approaches the vibrating surface from the farfield to the close nearfield. It is noted that the microphone should be separated from the source surface by at least a diameter of the microphone for an error ratio less than 2% in the low frequency range less than about 2.7kHz. This means that if one wants to put a microphone in the very close nearfield. a microphone with small diameter should be used.

  • PDF

Study of Incipient Soot Particles with Measuring Methodologies (입자 측정방법을 통한 초기 수트입자 연구)

  • Lee Eui Ju
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • The physical characteristics of soot near the soot inception point were investigated with various measurements. In-situ measurements of particle size and volume fraction were introduced based on time resolved laser-induced incandescence (TIRE-LII) and laser-induced ion mobility (LIIM). The one has more convenience and accuracy than conventional LII technique and the other works best for particle sizes of a few nanometers at high concentrations in a uniform concentration field. A complementary ex-situ measurement of particle size is nano differential mobility analyzer (Nano-DMA), which recently developed for measuring particle sizes between 2nm and 100nm and provides high-resolution size information for early soot. Particles will be also collected on transmission electron microscope (TEM) grids using rapid thermophoretic sampling and analyzed for morphology. These measurements will allow fresh and original insight into the characterizing soot inception process. The measured physical properties of incipient soot will clarify the controlling growth mechanism combined with chemical ones, and the dominant mechanism for soot modeling can be deduced from the information.

  • PDF