• 제목/요약/키워드: Nea

Search Result 177, Processing Time 0.022 seconds

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

솔잎 발효액이 식빵의 품질에 미치는 영향 (Effects of Fermentation Pine Needle Extract on the Quality of Plain Bread)

  • 최동만;이동선;정순경
    • 한국식품저장유통학회지
    • /
    • 제14권2호
    • /
    • pp.154-159
    • /
    • 2007
  • 식빵을 제조할 때 솔잎의 당 발효액을 설탕 대용으로 사용하면서 솔잎의 기능성을 제빵에 이용하고자 솔잎발효 액을 첨가하여 반죽에 대한 물성을 측정하고, 빵을 제조 후 실온에 저장하면서 제품의 품질 변화를 보았다. farinogram에 의한 반죽의 물성 평가에서 반죽에 대한 안정성과 혼합 내구성에서 설탕을 함유한 반죽보다 솔잎발효 액을 첨가한 처리구가 우수한 것으로 평가되었다. 또한 반죽의 발효에 영향을 미칠 수 있는 pH에서도 솔잎발효액 첨가 구에서 효모의 활성이 왕성할 수 있는 pH조건인 pH 5.4-5.8사이로 유지되었다. 반죽의 경도 역시 높지 않아 발효 중 가스 보지력에 영향을 줄 수 있는 반죽의 신장성이 우수함을 확인하였다. 제품의 부피와 비용적에 있어서도 대조구에 비교해서 솔잎발효 액의 함량이 많을수록 부피와 비용적이 각각 크고 높은 것으로 나타났다. 식빵의 저장 중 가장 중요하게 여기는 노화현상의 정도를 확인하기 위하여 저장중의 경도 변화를 측정한 결과에서는 대조구보다 처리구에서 노화가 억제됨을 확인할 수 있었고, 솔잎발효 액의 첨가량이 증가할수록 노화가 지연되는 것으로 나타났다. 또한 미생물 변화에 있어서도 총균수 및 곰팡이 균수에서 솔잎의 기능성인 항균력으로 인해 솔잎발효액의 처리구에서 미생물 생육이 억제됨을 확인하였다. 이상의 결과를 종합해 볼 때 솔잎발효액을 첨가함으로써 빵 반죽은 물론 완제품에 대해서 긍정적인 영향을 줌으로써 제빵의 품질은 물론 저장성뿐만 아니라 안전성 측면에서도 많은 기여를 할 수 있을 것으로 기대된다.

『용감한 사람들 Los bravos』에 나타난 공간의 의미 (The Meaning of Space in Los bravos)

  • 김선웅
    • 비교문화연구
    • /
    • 제46권
    • /
    • pp.173-197
    • /
    • 2017
  • 본 연구는 헤수스 페르난데스 산토스의 "용감한 사람들"에 나타난 공간의 의미를 연구했다. 주요 내용은 작품에 나타난 공간에 대한 다양한 측면을 담고 있다. 시간의 흐름에 따라 공간의 개념도 소설의 진화와 함께 변화되었음을 볼 수 있다. 과거 아리스토텔레스는 공간을 사물과 인물이 존재하는 곳으로 여겼다. 르네상스까지 이러한 개념이 유지되었다. 19세기에 공간은 당시 낭만주의 작가들이 그 중요성을 더 부여해서 단순한 행동 묘사에만 그치지 않았다. 그리고 이후 사실주의는 집 안 내부 등과 같이 구체적인 공간에 관심을 보였다. 본 논문에서는 "용감한 사람들"에서의 공간의 다양한 의미에 초점을 두었다. 우선 실재적인 공간과 이상적인 공간에 대하여 살펴보았고, 인물들에 따른 치유적인 공간도 찾아보았다. 도시와 시골의 대립적인 공간이 어떻게 묘사되었는지, 마지막으로는 남성과 여성의 대립적인 공간을 보았다. 연구에 따르면, 어떤 인물은 자신의 이상적인 공간을 찾아 떠나기 했고, 여자 인물들은 부엌이라는 공간에서 편안함을 찾았고, 남자들은 카페에 모여 친구들과 이야기를 하는 광경을 자주 볼 수 있었다. 문이나 창문은 집 안의 구조적인 경계일 수도 있지만, 남성과 여성의 심리적 경계가 되기도 했다.

Experimental assessment of thermal radiation effects on containment atmospheres with varying steam content

  • R. Kapulla;S. Paranjape;U. Doll;E. Kirkby;D. Paladino
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4348-4358
    • /
    • 2022
  • The thermal-hydraulics phenomena in a containment during an accident will necessarily include radiative heat transfer (i) within the gas mixture due to the high radiative absorption and emission of steam and (ii) between the gas mixture and the surrounding structures. The analysis of some previous PANDA experiments (PSI, Switzerland) demonstrated the importance of the proper modelling of radiation for the benefit of numerical simulations. These results together with dedicated scoping calculations conducted for the present experiments indicated that the radiative heat transfer is considerable, even for a very low amount of steam (≈2%). The H2P2 series conducted in the large-scale PANDA facility at the Paul-Scherrer-Institut (PSI) in the framework of the OECD/NEA HYMERES-2 project is intended to enhance the understanding of thermal radiation phenomena and to provide a benchmark for corresponding numerical simulations. Thus, the test matrix was tailored around the two opposite extremes: either gas compositions with small steam content such that radiative heat transfer phenomena can be neglected. Or gas mixtures containing larger amounts of steam, so that radiative heat transfer is expected to play a dominant role. The H2P2 series consists of 5 experiments designed to isolate the radiation phenomena from convective and diffusive effects as much as possible. One vessel with a diameter of 4 m and a height of 8 m was preconditioned with different mixtures of air / steam at room and elevated temperatures. This was followed by the build-up of a stable helium stratification at constant pressure in the upper part of the vessel. After that, helium was injected from the top into the vessel which leads to an increase of the vessel pressure and a corresponding elevation-dependent and transient rise of the gas temperature. It is shown that even the addition of small amounts of steam in the initial gas atmosphere considerably impacts the radiative heat transport throughout all phases of the experiments and markedly influences i) the monitored gas peak temperature, ii) the temperature history during the compression and iii) the following relaxation phase after the compression was stopped. These PANDA experiments are the first of its kind conducted in a large scale thermal-hydraulic facility.

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

사용후핵연료 심지층처분장부지 지질환경 기본요건 검토 (Study on Basic Requirements of Geoscientific Area for the Deep Geological Repository of Spent Nuclear Fuel in Korea)

  • 배대석;고용권;박주완;박진백;송종순
    • 방사성폐기물학회지
    • /
    • 제10권1호
    • /
    • pp.63-75
    • /
    • 2012
  • 사용후핵연료 심지층처분장 부지선정과 최종 처분장부지의 처분적합성을 평가하는 업무는 시행-착오를 줄이고 기술적 신뢰성 확보와 합리적이고 효율적인 업무수행을 추구하여야 한다. 이에 선행하여, 우리나라에 적용 가능한 처분장부지의 지질환경 요건 설정을 위한 기본방향과 개별 인자의 처분적합성지표를 가능한 한 정량화하여 설정하고 업무에 적용하여야 한다. 사용후핵연료 처분장부지 선정과 최종처분장 부지의 안전성확보를 위한 처분요건과 관련하여 IAEA 및 OECD 회원국들과 처분연구 및 상용사업 수행 관련 선진국가들의 사례를 바탕으로 요건 별로 구분하여 현황을 분석하였다. 여기서는 사용후핵연료 처분장 부지로서 암석 암반이 갖추어야 할 충분 혹은 선호요건에 대한 이해 제고와 관련 세부 기술지침을 도출하는데 기여하고자 하였다. 이를 토대로 어떠한 암석 암반이 상대적으로 보다 유리한 조건을 가지는 선호요건으로 제시해야 하는지, 그리고 충분요건과 선호요건을 적용하여 후보부지 조사 선별평가 기간 동안 부지선정업무에 반영하고 평가하고 결정하여야 하는 방법론을 도출할 수 있도록 기본 골격을 제시하였다. 또한 처분안전성 확보를 위해 필요한 기본적인 사항을 검토하고 서술하였다. 본 논문에서 기술한 항목들은 처분안전성 확보를 위한 처분요건의 기술지침 구성 체계, 처분안전성 확보개념, 다중방벽 기능 조건, 천연방벽의 지질환경 기본요건, 그리고 우리나라에 적용 가능한 처분장부지 지질환경 기본요건(안) 등으로 구성된다. 우리나라의 사용후핵연료 심지층처분장 부지의 위치에 관한 사업자 기술지침 요건으로 제안하였다. 이와 관련하여 충분요건과 선호요건으로, 화산활동, 지진활동, 단층운동 융기 침강 운동 및 기후 해수면변동 등 장기지질안정성 요건을 비롯한 15개 충분요건과 48개 선호요건을 제안하였다. 이들 요건은 우리나라의 지질환경 특성을 충분히 반영하여 후속되는 각 부문별 특성에 적합한 정량적인 기술 기준 및 지침으로 개발되어야 할 것이다. 정량적 기술지침의 도출은 상용 처분장부지 선별평가과정 및 처분장 부지적합성평가 과정으로부터 확립될 수 있을 것이다. 또한 다양한 부문별 안전사례(safety case) 작성 혹은 연구용 지하처분연구시설 (underground research laboratory: URL)을 이용한 처분시스템의 실증과정 등을 통하여 객관적이고 신뢰성있는 정량적인 지침들이 확립될 수 있을 것이다.

호흡기능장애와 관련된 간호진단의 타당도 조사 (Validity of Nursing Diagnoses Related to Difficulty in Respiratory Function)

  • 김조자;이원희;유지수;허혜경;김창희;홍성경
    • 대한간호학회지
    • /
    • 제23권4호
    • /
    • pp.569-584
    • /
    • 1993
  • This study was done to verify validity of nursing diagnoses related to difficulty in respiratory function. First, content validity was examined by an expert group considering the etiology and the signs / symptoms of three nursing diagnoses - ineffective airway clearance, ineffective breathing pattern, impaired gas exchange. Second, clinical validity was examined by comparing the frequencies of the etiologies and signs / symptoms of the three nursing diagnoses in clinical case studies with the results of the content validity. This study was a descriptive study. The sample consisted of 23 experts (professors, head nurses and clinical instructors) who had had a variety of experiences using nursing diagnoses in clinical practice, and 102 case reports done by senior student nurses of the college of nursing of Y-university. These reports were part of their clinical practice in the ICU. The instrument used for this study was a checklist for etiologies and signs and symptoms based on the literature, Doenges and Moorhouse (1988), Kim, McFarland, McLane (1991), Lee Won Hee et al. (1987), Kim Cho Ja et at. (1988). The data was collected over four month period from May 1992 to Aug. 1992. Data were analyzed using frequencies done with the SPSS / PC+ package. The results of this study are summarized as follows : 1. General Characteristics of the Expert Group A bachelor degree was held by 43.5% and a master or doctoral degree by 56.5% of the expert group. The average age of the expert group was 35.3 years. Their average clinical experience was 9.3 years and their average experience in clinical practice was 5.9 years. The general characteristics of the patients showed that there were more women than men, that the age range was from 1 to over 80. Most of their medical diagnoses were diagnoses related to the respiratory. system, circulation or neurologic system, and 50% or more of them had a ventilator with intubation or a tracheostomy. The number of cases for each nursing diagnoses was : · Ineffective airway clearance, 92 cases. · Ineffective breathing pattern, 18 cases. · Impaired gas exchange, 22 cases. 2. The opinion of the expert group as to the classification of the etiology, and signs and symptoms of the three nursing diagnoses was as follows : · In 31.8% of the cases the classification of etiology was clear. · In 22.7%, the classification of signs and symptoms was clear. · In 17.4%, the classification of nursing interventions was clear. 3. In the expert group 80% or mere agreed to ‘dysp-nea’as a common sign and symptom of the three nursing diagnoses. The distinguishing signs and symptoms of (Ineffective airway clearance) were ‘sputum’, ‘cough’, ‘abnormal respiratory sounds : rales’. The distinguishing sings and symptoms of (Ineffective breathing pattern) were ‘tachypnea’, ‘use of accessory muscle of respiration’, ‘orthopnea’ and for (Impaired gas exchange) it was ‘abnormal arterial blood gas’, 4. The distribution of etiology, and signs and symptoms of the three nursing diagnoses was as follows : · There was a high frequency of ‘increased secretion from the bronchus and trachea’ in both the expert group and the case reports as the etiology of ineffective airway clearance. · For the etiologies for ineffective breathing pat-tern, ‘rain’, ‘anxiety’, ‘fear’, ‘obstructions of the tract, ca and bronchus’ had a high ratio in the ex-pert group and ‘decreased expansion of lung’ in the case reports. · For the etiologies for impaired gas exchanges, ‘altered oxygen -carrying capacity of the blood’ and ‘excess accumulation of interstitial fluid in lung’ had a high ratio in the expert group and ‘altered oxygen supply’ in the case reports. · For signs and symptoms for ineffective airway clearance, ‘dyspnea’, ‘altered amount and character of sputum’ were included by 100% of the expert group. ‘Abnormal respiratory. sound(rate, rhonchi)’ were included by a high ratio of the expert group. · For the signs and symptoms for ineffective breathing pattern. ‘dyspnea’, ‘shortness of breath’ were included by 100% of the expert group. In the case reports, ‘dyspnea’ and ‘tachypnea’ were reported as signs and symptoms. · For the sign and symptoms for impaired gas exchange, ‘hypoxia’ and ‘cyanosis’ had a high ratio in the expert group. In the case report, ‘hypercapnia’, ‘hypoxia’ and ‘inability to remove secretions’ were reported as signs and symptoms. In summary, the similarity of the etiologies and signs and symptoms of the three nursing diagnoses related to difficulty in respiratory function makes it difficult to distinguish among them But the clinical validity of three nursing diagnoses was established through this study, and at last one sign and symp-tom was defined for each diagnosis.

  • PDF