• Title/Summary/Keyword: Natural Standard

Search Result 1,773, Processing Time 0.028 seconds

Transition of Isc according to Natural Solar Spectrum on c-Si and a-Si PV Module (결정질과 비정질 PV모듈의 자연광 스펙트럼에 따른 Isc의 변화)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.86-91
    • /
    • 2009
  • In this paper, we analyze the Transition of Isc by natural solar spectrum of c-Si and a-Si PV module. Commonly, performance of photovoltaic (PV) module is estimated under the standard test condition (STC). That is, solar irradiance $1kW/m^2$, solar spectrum distribution: AM1 5G, module temperature $25^{\circ}C$ This means it rarely meets actual outdoor conditions. The solar spectrum always changes. So it is rare to fit the standard solar spectrum AM1 5G defined in ASTM G173-03 or IEC 60904-3. Thus spectral response of PV module is different depending on the material. so we estimated the variation of Isc at every minutes by comparing c-Si PV module with a-si PV module for outdoor conditions.

  • PDF

A Study of Comparison of Temperature Seasons and Biotic Seasons in Jeonnam Region

  • Hwang, Sung Eun;Ryu, Chan Su
    • Journal of Integrative Natural Science
    • /
    • v.6 no.2
    • /
    • pp.118-123
    • /
    • 2013
  • Korea, which is located in the middle-latitude area of the northern hemisphere, has four seasons. These seasons can be classified based on their months, mean temperatures, biology and natural phenomena. In this study, climatic changes were identified by biotic and temperature seasons, changing trends were compared by season, and the appropriateness of the biotic phenomena for the biotic season classification was examined. The data for this study included the mean temperatures, and biology phenomenon observation dates, which had been observed for 38 years from the ASOSs in seven Gwangju and Jeonnam regions. Limitations were found in the classification of the temperature and biotic seasons. Especially in the case of the biotic season based on a single life, the points of the first sighting and the initial sound fluctuated so much that the accuracy of the results was not guaranteed. Therefore, the life species had to be selected subject to detailed verification and accurate specifications, and to be applied to the meteorological phenomena. In addition, there were lives in the standard biology that could no longer be observed because of environmental pollution and climatic change, which indicates the need to protect the existing standard biology.

A Study Identifying Improved Building Height Regulations for Managing Natural Landscape in Collective Facility Districts in and around National Parks (국립공원 집단시설지구 자연경관관리를 위한 층고규제 합리화 방안)

  • Lee, Gwan-Gyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.5
    • /
    • pp.48-56
    • /
    • 2011
  • The objective of this study is to develop quantitative criteria for setting reasonable standards and regulations for building heights in collective facility districts inside national parks or those connected to their borders. Heights of all building sin collective facility districts were simulated in order to determine heights of ridge lines of sight passing the upper parts of buildings from a main view point. Where a facility's zone is located at the inside or boundary of inland mountainous national parks, and there are coastal type national parks with mountains in the background, the study recommended assigning the maximum allowable height of a building as 8.82m if national park authorities intend to preserve the ridges at three-tenths the height of a mountain. It amounts to 3 or 3.5 stories when it is converted into the number of floors. It is desirable to apply this standard to accommodations like a hotel except lodge or cottage as the maximum allowable height of a building. Nevertheless, when there aren't back mountainous areas among coastal-type national parks, there is a need for applying a separate standard. If an equal and uniform standard is applied to all collective facility districts, it becomes difficult to address local differences when managing landscape. There must be flexibility when applying a standard, depending on variables such as location of view points, differences in the methods of selection of view points, and differences in view angles, etc. Thus, there is a need for different landscape management strategies that address the unique natural environment of different zones.

Study on the Interaction of U(VI) Species With Natural Organic Matters in KURT Groundwater (KURT 지하수의 천연 유기물질과 6가 우라늄 화학종의 상호작용에 관한 연구)

  • Jung, Euo Chang;Baik, Min Hoon;Cho, Hye-Ryun;Kim, Hee-Kyung;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.101-116
    • /
    • 2017
  • The interaction of U(VI) (hexavalent uranium) species with natural organic matter (NOM) in KURT (KAERI Underground Research Tunnel) groundwater is investigated using a laser spectroscopic technique. The luminescence spectra of the NOM are observed in the ultraviolet and blue wavelength regions by irradiating a laser beam at 266 nm in groundwater. The luminescence spectra of U(VI) species in groundwater containing uranium concentrations of $0.034-0.788mg{\cdot}L^{-1}$ are measured in the green-colored wavelength region. The luminescence characteristics (peak wavelengths and lifetime) of U(VI) in the groundwater agree well with those of $Ca_2UO_2(CO_3)_3(aq)$ in a standard solution prepared in a laboratory. The luminescence intensities of U(VI) in the groundwater are weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. The luminescence intensities of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution mixed with the groundwater are also weaker than those of $Ca_2UO_2(CO_3)_3(aq)$ in the standard solution at the same uranium concentrations. These results can be ascribed to calcium-U(VI)-carbonate species interacting with NOM and forming non-radiative U(VI) complexes in groundwater.

A literature review on expansion of dental hygienists' radiography operations (치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰)

  • Choi, Young-Suk;Kim, Jin-Kyoung;Jang, Jong-Hwa;Park, Yong-Duk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF

A Research on the Application of Eco-Friendly Approval Criteria in Forest Land-use (자연친화적 산지이용허가기준 적용 방안 연구)

  • Park, Shin-Won;Choi, Sang-Hee;Cho, Young-Tae
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.33-43
    • /
    • 2012
  • The research which it sees is the simulation research for "The Ecological Diversion of Forest Land-Use System". It accomplished the simulation which applies a permission standard, it developed escape it did a model and the basic draft. From the research which it sees in order to investigate the application characteristic of natural intimate mountain district application standard the mountain district whole aspect instance middle actual object a time mountain district use standard about under selecting which it will yell it applied. "Natural intimate mountain district development standard triangular position plan research" from compatibility of the mode of life mountain district whole aspect permission standard which is proposed about under investigating it presented the improvement program and a institutional improvement direction of corresponding standard. About under preserving plan it applies the yearly environment the mountain district to sleep it prepares the foundation for it accomplished the transcendental research for. With the achievement resources which the mountain district has resultantly must preserve a value, limit of the development size it will be able to minimize the effect which it follows in development, the arrangement method back could be proposed, also the case which will use the mountain district where it is damaged induces the development which cabinets to the concept of demobilization, the case which will apply the existing forest resources takes a triangular position with the act it will be able to increase the circulating value of the resources and will do.

A Comparative Study on the Formation of Methane Hydrate Using Natural Zeolite and Synthetic Zeolite 5A (천연 제올라이트와 합성 제올라이트 5A를 이용한 메탄 하이드레이트의 생성에 대한 비교 연구)

  • Park, Sung-Seek;Park, Yun-Beom;Kim, Nam-Jin
    • New & Renewable Energy
    • /
    • v.8 no.2
    • /
    • pp.24-32
    • /
    • 2012
  • Natural gas hydrates have a high potential as the 21st century new energy resource, because it have a large amount of deposits in many deep-water and permafrost regions of the world widely. Natural gas hydrate is formed by physical binding between water molecule and gas mainly composed of methane, which is captured in the cavities of water molecules under the specific temperature and pressure. $1m^3$ methane hydrate can be decomposed to the methane gas of $172m^3$ and water of $0.8m^3$ at standard condition. Therefore, there are a lot of practical applications such as separation processes, natural gas storage transportation and carbon dioxide sequestration. For the industrial utilization of methane hydrate, it is very important to rapidly manufacture hydrate. However, when methane hydrate is artificially formed, its reaction time may be too long and the gas consumption in water becomes relatively low, because the reaction rate between water and gas is low. So in this study, hydrate formation was experimented by adding natural zeolite and Synthetic zeolite 5A in distilled water, respectively. The results show that when the Synthetic zeolite 5A of 0.01 wt% was, the amount of gas consumed during the formation of methane hydrate was higher than that in the natural zeolite. Also, the natural zeolite and Synthetic zeolite 5A decreased the hydrate formation time to a greater extent than the distilled water at the same subcooling temperature.

Performance of Hanwoo calves fed a commercial colostrum replacer versus natural bovine colostrum

  • Ahmadi, Farhad;Kim, Seongjin;Hwangbo, Deok;Oh, Yongik;Yu, Jisu;Bae, Jisun;Kim, Na Yeon
    • Journal of Animal Science and Technology
    • /
    • v.63 no.5
    • /
    • pp.1114-1125
    • /
    • 2021
  • Supplying a sufficient amount of high-quality colostrum is a prevailing challenge in Hanwoo calf production systems. This study aimed to describe the efficiency of a lacteal-derived colostrum replacer versus natural bovine colostrum (from Holstein) fed to Hanwoo calves. Forty newborn Hanwoo calves (25 males and 15 females; 30.7 ± 3.15 kg body weight [mean ± standard deviation]) were blocked by sex and birth weight and fed either natural colostrum or a commercial colostrum replacer. Calves displayed a narrow difference in the evolution of body weight and structural body dimensions when they received a commercial versus natural colostrum. Minor differences existed in the starter and total dry matter consumption between calves fed natural or commercial colostrum. Although the colostrum source had no significant effects on days to first diarrhea (average of 7.6 days; p = 0.17), the duration of diarrhea was longer in natural colostrum-fed calves (3.2 vs. 4.5 days; p = 0.04). Consumption of natural colostrum resulted in greater mean serum immunoglobulin G (IgG) on day 2 (14.7 vs. 10.8 ± 0.92 mg/mL) and day 7 (8.21 vs. 5.12 ± 0.82 mg/mL) of calf life, resulting in a greater proportion of commercial colostrum-fed calves (50% vs. 15%; day 2) to experience failure of passive transfer of immunity (serum IgG < cutoff point of 10 mg/mL). Overall, growth rate, body frame development, and incidence of diarrheal disease were not different in both groups. These results suggested that the colostrum replacer product tested in this study could be an alternative to natural colostrum derived from Holstein cow in securing calf growth and health in Hanwoo calf-rearing operations.

A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China- (인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로-)

  • Back, Seong-Kyung;Lee, Seung-Hoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

A NEW STOCHASTIC EVALUATION THEORY OF ARBITRARY ACOUSTIC SYSTEM RESPONSE AND ITS APPLICATION TO VARIOUS TYPE SOUND INSULATION SYSTEMS -EQUIVALENCE TRANSFORMATION TOWARD THE STANDARD HERMITE AND/OR LAGUERRE EXPANSION TYPE PROBABILITY EXPRESSIONS

  • Ohta, Mitsuo;Ogawa, Hitoshi
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.692-697
    • /
    • 1994
  • In the actual sound environmental systems, it seems to be essentially difficult to exactly evaluate a whole probability distribution form of its response fluctuation, owing to various types of natural, social and human factors. Up to now, we very often reported two kinds of unified probability density expressions in the standard expansion from of Hermite and Laguerre type orthonormal series to generally evaluate non-Gaussian, non-linear correlation and/or non-stationary properties of the fluctuation phenomenon. However, in the real sound environment, there still remain many actual problems on the necessity of improving the above two standard type probability expressions for practical use. In this paper, first, a central point is focused on how to find a new probabilistic theory of practically evaluating the variety and complexity of the actual random fluctuations, especially through introducing some equivalence transformation toward two standard probability density expressions mentioned above in the expansion from of Hermite and Laguerre type orthonormal series. Then, the effectiveness of the proposed theory has been confirmed experimentally too by applying it to the actual problems on the response probability evaluation of various sound insulation systems in an acoustic room.

  • PDF