• 제목/요약/키워드: National response system

검색결과 3,085건 처리시간 0.03초

화학사고의 효율적 대응을 위한 정보공유체계 개선 연구 (Improvement of Information Sharing System for Efficient Response of Chemical Accident)

  • 이태형;윤정현;허화진;이율범;유병태
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.54-61
    • /
    • 2018
  • In this study, we developed a system for information sharing and cooperation support system among the accident response organizations to enable prompt and efficient response in responding to chemical accidents. In other words, by applying mobile messenger function, it is proposed to improve the chemical accident response system that provides information necessary for accident response promptly and accurately, and facilitates bi-directional communication between accident response organizations and field responders, thereby enabling efficient and organic response. As a result of comparing the information provision time before and after the chemical accident of chemical accident response information sharing system, the ratio of processing of substance information and chemical air diffusion information within 30 minutes was improved by 8% and 32%, respectively. As a result of this study, applying the chemical accident response information sharing system to the chemical accident response is expected to contribute to the improvement of the system and the ability to cope with the accident more effectively.

AHP기법을 활용한 제조물책임 대응시스템 구축요인의 전략적 우선순위 도출에 관한 연구 (Extracting Priorities of Strategic Components of Product Liability Response System using AHP)

  • 서준혁;고복수;배성민
    • 품질경영학회지
    • /
    • 제42권2호
    • /
    • pp.235-251
    • /
    • 2014
  • Purpose: To develop efficient PL response system, SMEs should decide which component of PL response system is important and implemented with priority under limited resources. To accomplish this goal, we propose strategic priority components of PL response system for SME manufacturer. Methods: We categorize the components of PL response system based on prior research results - System, Organization, Training, Technology, Cost, and Awareness. AHP (Analytic Hierarchy Process) is applied to extract important components of PL response system, which is used in assigning the priority of component. To analyze effects of each components, performance sensitivity analysis is applied. Results: The survey analysis results show Technology is the most important components. Organization and Cost component are follows. As the importance of Technology is changed, we can find Organization, Cost is second and third important components. Conclusion: Our research shows Technology which is related to make a safe product with systematic process, is a basic enabler of PL response system. Also, building a PL team and securing a budget for PL activity should be carry out with limited resources.

대형 재난의 효율적 대응을 위한 소방조직 중심의 재난대응체계 개편 방안 (Reorganization of Disaster Management Systems for Effective Emergency and Disaster Response: The Pivotal Role of The National Emergency Management Agency (NEMA))

  • 문기식
    • 대한안전경영과학회지
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2017
  • The current study aims to propose a reorganization plan for the national emergency management system to improve the current organizational structure for responding to national disasters and emergency situations. As a theoretical framework, the current study identified four key elements of successful disaster response systems: responsiveness, controllability, expertise, and devotedness. On the basis of the four key elements of disaster response systems, this study critically reviewed the current state of the organizational structure of the Korean national emergency response system by discussing the issues inherent in the current structure and by doing a comparative analysis of two high-profile national disaster cases-the Sewol ferry disaster in 2014 and the Gwangsan Rescue of buried people in 2013. Then, this study proposed the reorganization plan for the national disaster response system in which the NEMA is under direct control of the Prime Minister of Korea. It coordinates and controls the related government departments, such as the police, maritime police, and military during the national disaster and emergency situation. This study also proposed a reorganizational plan for the regional disaster response system in Korea. Finally, it was suggested that the status of firefighters should be elevated to the national public servant level in order to achieve organizational efficiency and solve existing problems that come from the current separated systems.

우리나라 기름오염방제제도의 문제점과 개선방안 (National Oil Pollution Response System : Current Issues and Policy Recommendation)

  • 목진용
    • 해양환경안전학회지
    • /
    • 제7권2호
    • /
    • pp.105-121
    • /
    • 2001
  • After the Sea Prince oil spill accident in 1995, the korean government has taken a measure to establish an emergency response system and equip clean-up capacity against large spill, major contents of which are as follows: First, Korea Marine Pollution Response Corporation has been established as a non-government organization for recovery of spilled oil in order to improve private response capabilities. Second, clean-up equipments, such as large clean-up vessels and oil fences for the open sea operation has been expanded. Third, a national contingency plan on the large spill accidents has been established compliance with the provisions of Article 6 of the OPRC 1990. However, there exist some problems in the national response system, such as clearly roles definition between government and private agencies; propel amendment of the Marine Pollution Prevention Act to incorporate major contents of the OPRC 1990; and training and exercises of clean-up personnel. With the above problems in mind, this paper reviews the current issues on the national oil pollution response system and recommends policy-making to tackle to those problems.

  • PDF

The Design of an Optimal Demand Response Controller Under Real Time Electricity Pricing

  • Jin, Young Gyu;Choi, Tae-Seop;Park, Sung Chan;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.436-445
    • /
    • 2013
  • The use of a demand response controller is necessary for electric devices to effectively respond to time varying price signals and to achieve the benefits of cost reduction. This paper describes a new formulation with the form of constrained optimization for designing an optimal demand response controller. It is demonstrated that constrained optimization is a better approach for the demand response controller, in terms of the ambiguity of device operation and the practicality of implementation of the optimal control law. This paper also proposes a design scheme to construct a demand response controller that is useful when a system controller is already adapted or optimized for the system. The design separates the demand response function from the original system control function while leaving the system control law unchanged. The proposed formulation is simulated and compared to the system with simple dynamics. The effects of the constraints, the system characteristics and the electricity price are examined further.

유압제어계통의 액추에이터 응답시간 특성변화에 관한 실험적 연구 (A Experimental Study on the Response Time Characteristics of Actuator in the Hydraulic Control System)

  • 이주성;이계복
    • 한국산업융합학회 논문집
    • /
    • 제5권1호
    • /
    • pp.21-26
    • /
    • 2002
  • Response time of actuator in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary, Occasionally the appropriate response time is not easily determined. This study is on the characteristics of response time in the hydraulic system.

  • PDF

국내 방사능재난대응체계 실효성 제고를 위한 제언 (Suggestions to Improve the Effectiveness of National Radiological Emergency Response System)

  • 문주현
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.195-206
    • /
    • 2020
  • 국내 방사능재난대응체계는 일본 후쿠시마 원전 사고와 최근의 국내 대형 재난 교훈 등을 바탕으로 개선돼 오고 있지만, 아직 방사능재난 특성과 후쿠시마 원전 사고 교훈을 완전히 반영하고 있지 못하다. 하나의 방사능재난대응체계에 복수의 국내법이 적용되면서, 실제 상황 시, 대응체계의 실효성을 훼손할 가능성이 있는 법 조항 간 불일치 사항이 존재하기도 한다. 이에 본 논문에서는 방사능재난대응 속성을 분석하고, 방사능재난대응체계 적절성 측면에서 「재난 및 안전관리 기본법」과 「원자력시설 등의 방호 및 방사능 방재 대책법」에서 규정한 방사능재난대응체계, 후쿠시마 원전 사고 시 일본측의 방사능 재난 대응 활동을 분석하고, 이 분석결과를 토대로, 대응체계와 조직 측면에서 국내 방사능재난대응체계 실효성을 제고하기 위해 필요한 개선사항을 도출하여 제시하였다.

발전기 여자 시스템 속응성 개선을 위한 예측제어 전류 기법 (Predictive current control for fast response of generator excitation system)

  • 이병구;홍현문;최재호;류홍우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.416-418
    • /
    • 1997
  • Stable power source and fast control response are important for the generator excitation system. To stabilize the control of excitation circuit the PI controller for excitation current has been used. But the response of the system with this conventional control technique is very poor, especially in transient response with a predictive current control, the response of the excitation system can be improved. In this study, it is verified by the PSIM simulation.

  • PDF

수송안전정보시스템 개발 (Development of HAZMAT Information System)

  • 안승범;김시곤;김용진;홍우식
    • 대한안전경영과학회지
    • /
    • 제6권2호
    • /
    • pp.49-65
    • /
    • 2004
  • Ministry of Environment developed ‘Emergency Response Information System (ERIS)’ in 2001, which is in operation. As a next step, currently National Emergency Response Information System (NERIS) is being developed. The main difference among ERIS and NERIS is to enhance the system in the national level, including transportation of hazardous materials. This paper introduces concepts and methods applied to NERIS, especially HAZMAT, and the information system, operating strategies. Based on GIS and transportation-network data, the best route can be offered using Risk Analysis. Strategies for reporting and first-response information systems are also designed for emergencies in the paper.

3상 위상제어 정류기를 위한 DVR의 반응시간 최적화 (Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier)

  • 박철우;정수경;류지열;이대섭
    • 제어로봇시스템학회논문지
    • /
    • 제19권3호
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.