• Title/Summary/Keyword: National response system

Search Result 3,085, Processing Time 0.037 seconds

Improvement of Information Sharing System for Efficient Response of Chemical Accident (화학사고의 효율적 대응을 위한 정보공유체계 개선 연구)

  • Lee, Taehyung;Yun, Jeonghyeon;Heo, Hwajin;Lee, Yulburm;Yoo, Byungtae
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.54-61
    • /
    • 2018
  • In this study, we developed a system for information sharing and cooperation support system among the accident response organizations to enable prompt and efficient response in responding to chemical accidents. In other words, by applying mobile messenger function, it is proposed to improve the chemical accident response system that provides information necessary for accident response promptly and accurately, and facilitates bi-directional communication between accident response organizations and field responders, thereby enabling efficient and organic response. As a result of comparing the information provision time before and after the chemical accident of chemical accident response information sharing system, the ratio of processing of substance information and chemical air diffusion information within 30 minutes was improved by 8% and 32%, respectively. As a result of this study, applying the chemical accident response information sharing system to the chemical accident response is expected to contribute to the improvement of the system and the ability to cope with the accident more effectively.

Extracting Priorities of Strategic Components of Product Liability Response System using AHP (AHP기법을 활용한 제조물책임 대응시스템 구축요인의 전략적 우선순위 도출에 관한 연구)

  • JunHyeok, Seo;BokSoo, Ko;Bae, SungMin
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.2
    • /
    • pp.235-251
    • /
    • 2014
  • Purpose: To develop efficient PL response system, SMEs should decide which component of PL response system is important and implemented with priority under limited resources. To accomplish this goal, we propose strategic priority components of PL response system for SME manufacturer. Methods: We categorize the components of PL response system based on prior research results - System, Organization, Training, Technology, Cost, and Awareness. AHP (Analytic Hierarchy Process) is applied to extract important components of PL response system, which is used in assigning the priority of component. To analyze effects of each components, performance sensitivity analysis is applied. Results: The survey analysis results show Technology is the most important components. Organization and Cost component are follows. As the importance of Technology is changed, we can find Organization, Cost is second and third important components. Conclusion: Our research shows Technology which is related to make a safe product with systematic process, is a basic enabler of PL response system. Also, building a PL team and securing a budget for PL activity should be carry out with limited resources.

Reorganization of Disaster Management Systems for Effective Emergency and Disaster Response: The Pivotal Role of The National Emergency Management Agency (NEMA) (대형 재난의 효율적 대응을 위한 소방조직 중심의 재난대응체계 개편 방안)

  • Mun, Gi-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • The current study aims to propose a reorganization plan for the national emergency management system to improve the current organizational structure for responding to national disasters and emergency situations. As a theoretical framework, the current study identified four key elements of successful disaster response systems: responsiveness, controllability, expertise, and devotedness. On the basis of the four key elements of disaster response systems, this study critically reviewed the current state of the organizational structure of the Korean national emergency response system by discussing the issues inherent in the current structure and by doing a comparative analysis of two high-profile national disaster cases-the Sewol ferry disaster in 2014 and the Gwangsan Rescue of buried people in 2013. Then, this study proposed the reorganization plan for the national disaster response system in which the NEMA is under direct control of the Prime Minister of Korea. It coordinates and controls the related government departments, such as the police, maritime police, and military during the national disaster and emergency situation. This study also proposed a reorganizational plan for the regional disaster response system in Korea. Finally, it was suggested that the status of firefighters should be elevated to the national public servant level in order to achieve organizational efficiency and solve existing problems that come from the current separated systems.

National Oil Pollution Response System : Current Issues and Policy Recommendation (우리나라 기름오염방제제도의 문제점과 개선방안)

  • 목진용
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.7 no.2
    • /
    • pp.105-121
    • /
    • 2001
  • After the Sea Prince oil spill accident in 1995, the korean government has taken a measure to establish an emergency response system and equip clean-up capacity against large spill, major contents of which are as follows: First, Korea Marine Pollution Response Corporation has been established as a non-government organization for recovery of spilled oil in order to improve private response capabilities. Second, clean-up equipments, such as large clean-up vessels and oil fences for the open sea operation has been expanded. Third, a national contingency plan on the large spill accidents has been established compliance with the provisions of Article 6 of the OPRC 1990. However, there exist some problems in the national response system, such as clearly roles definition between government and private agencies; propel amendment of the Marine Pollution Prevention Act to incorporate major contents of the OPRC 1990; and training and exercises of clean-up personnel. With the above problems in mind, this paper reviews the current issues on the national oil pollution response system and recommends policy-making to tackle to those problems.

  • PDF

The Design of an Optimal Demand Response Controller Under Real Time Electricity Pricing

  • Jin, Young Gyu;Choi, Tae-Seop;Park, Sung Chan;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.436-445
    • /
    • 2013
  • The use of a demand response controller is necessary for electric devices to effectively respond to time varying price signals and to achieve the benefits of cost reduction. This paper describes a new formulation with the form of constrained optimization for designing an optimal demand response controller. It is demonstrated that constrained optimization is a better approach for the demand response controller, in terms of the ambiguity of device operation and the practicality of implementation of the optimal control law. This paper also proposes a design scheme to construct a demand response controller that is useful when a system controller is already adapted or optimized for the system. The design separates the demand response function from the original system control function while leaving the system control law unchanged. The proposed formulation is simulated and compared to the system with simple dynamics. The effects of the constraints, the system characteristics and the electricity price are examined further.

A Experimental Study on the Response Time Characteristics of Actuator in the Hydraulic Control System (유압제어계통의 액추에이터 응답시간 특성변화에 관한 실험적 연구)

  • Lee, Joo-Seong;Lee, Kye-Bock
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • Response time of actuator in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary, Occasionally the appropriate response time is not easily determined. This study is on the characteristics of response time in the hydraulic system.

  • PDF

Suggestions to Improve the Effectiveness of National Radiological Emergency Response System (국내 방사능재난대응체계 실효성 제고를 위한 제언)

  • Moon, Joo Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.195-206
    • /
    • 2020
  • Although the national radiological emergency response system has been improved by incorporating lessons from the Fukushima nuclear power plant accident and recent domestic natural disasters, it has not fully incorporated these lessons. In addition, it cannot deal with a variety of aftermath of the radiological disaster. Even for the same disaster, the national emergency response system should comply with multiple domestic laws in our country. Furthermore, there are a few discrepancies between the articles of the domestic laws that the national radiological emergency response system should address. Therefore, this study investigates the characteristics of radiological disasters, examines articles on the domestic laws related to the national radiological emergency response system, and analyses the Japanese government's responses to the Fukushima nuclear power plant accident. Based on the results of the review, suggestions for the improvement of the national radiological emergency response system in terms of response organization and framework have been proposed in this study.

Predictive current control for fast response of generator excitation system (발전기 여자 시스템 속응성 개선을 위한 예측제어 전류 기법)

  • Lee, B.K.;Moon, S.P.;Choi, J.H.;Rhew, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.416-418
    • /
    • 1997
  • Stable power source and fast control response are important for the generator excitation system. To stabilize the control of excitation circuit the PI controller for excitation current has been used. But the response of the system with this conventional control technique is very poor, especially in transient response with a predictive current control, the response of the excitation system can be improved. In this study, it is verified by the PSIM simulation.

  • PDF

Development of HAZMAT Information System (수송안전정보시스템 개발)

  • 안승범;김시곤;김용진;홍우식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.2
    • /
    • pp.49-65
    • /
    • 2004
  • Ministry of Environment developed ‘Emergency Response Information System (ERIS)’ in 2001, which is in operation. As a next step, currently National Emergency Response Information System (NERIS) is being developed. The main difference among ERIS and NERIS is to enhance the system in the national level, including transportation of hazardous materials. This paper introduces concepts and methods applied to NERIS, especially HAZMAT, and the information system, operating strategies. Based on GIS and transportation-network data, the best route can be offered using Risk Analysis. Strategies for reporting and first-response information systems are also designed for emergencies in the paper.

Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier (3상 위상제어 정류기를 위한 DVR의 반응시간 최적화)

  • Park, Chul-Woo;Joung, Sookyoung;Ryu, Jee-Youl;Lee, Dae-Seup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.