• Title/Summary/Keyword: National measurements standards

Search Result 169, Processing Time 0.03 seconds

A Study on the Development of Jeans Pattern and Grading Method (청바지 패턴 및 그레이딩에 관한 연구)

  • 정선희;이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.9_10
    • /
    • pp.1048-1059
    • /
    • 2003
  • This study focusses pattern draft and grading of jeans for women in their 20s, who consume jeans the most. Pattern was drafted based on existing patterns collected from companies. It is different from the existing educational patterns. It suggests new sizing system for twenties referring to sizes used companies and grading rule and method. he results were as follows; 1. Companies manufacture 2-8 sizes and they referred to the Korean Industrial Standards, KS K 0051, for their sizing system. 2. Drawing method for Pattern of the study had following measurements for each part: in the case of waist circumference, front part was W/4+1.5cm, back part was W14+2cm, front hip circumference was H/4-1.5cm, crotch line was the crotch length (practical measurement), hip circumference was (upper crotch line length)/5+0.5cm, front crotch part was 2.7cm, back crotch part was W/5+2.7cm, knee height was (the length of leg)/2+6cm and the circumference of knee and the tip of pants were 40cm. Through the wearing test on the subject of twenties, researched pattern received higher ratings, especially in appearance than the existing pattern. 3. 5 sizes system was made referred to the sizing system of companies and National Anthropometric Survey of Korean in 1997 Grading rule for 12 grading points of front part and 13 grading points of back part was suggested. Results of wearing test on the graded patterns showed high ratings similar to standard size.

A Study on the Development of Torso Pattern for an Automated Order-based Manufacturing System - focused on women in the twenties - (주문생산을 위한 자동제도 토르소 원형연구 -20대 여성을 중심으로-)

  • Hwan, Soo-Yeun;Nam, Yun-Ja
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.67-80
    • /
    • 2002
  • An efficient torso pattern has been developed to cope with the future trend of order-based, individualized production like the E.C.(Electronic Commerce) in the apparel industry, and to make a database foundation of automatic garment pattern drafting. For this purpose, a non-contact three-dimensional anthropometric measurement system was used to provide a lot of accurate body data for better individual fit, and an automatic pattern drafting system that can easily generate various size patterns and construct a pattern database has been developed too. The subjects of this research were 18 to 24 year-old women whose data had been gathered through the Korean national investigation of anthropometry for industrial standards in 1997 and various body shapes were analyzed by the measurements. And a special software system has been developed to verify the validity of newly proposed drawing rules. The results of sensory evaluation for appearance and moving fitness of the new torso pattern showed a significant improvement in individual fit even for the figures with large deviation from standard shape compared with the results of the traditional one.

Precise Temperature Control by Adjusting Flow of Liquid Nitrogen (액체 질소의 흐름 조절을 통한 저온 정밀 온도 제어)

  • Yang, Inseok;Lee, Jee-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.65-70
    • /
    • 2016
  • We devised a method to control the temperature of a liquid bath as low as $-100^{\circ}C$ using the duty cycle control of a solenoid valve. The solenoid valve controls the flow of liquid nitrogen that we used as a cryogen in this system. By controlling the duty cycle of a solenoid valve using feedback from the measured temperature of the liquid bath, we were able to achieve temperature stability within ${\pm}19mK$ around $-100^{\circ}C$. We also demonstrated that by taking average values of the temperature readings for sequence of measurements from more than one thermometer, it is possible to use this system for the calibration of thermometers within 3 mK. This system and the control method can be used for the precise temperature control in the range between $0^{\circ}C$ and $-100^{\circ}C$, where commercially available precision baths are much expensive and hard to be built in customized configurations.

Study on Characterization of Hydrophilic and Hydrophobic Fractions of Water-soluble Organic Carbon with a XAD Resin (XAD 수지에 의한 친수성 및 소수성 수용성 유기탄소의 특성조사)

  • Jeong, Jae-Uk;Kim, Ja-Hyun;Park, Seung-Shik;Moon, Kwang-Joo;Lee, Seok-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.337-346
    • /
    • 2011
  • 24-hr integrated measurements of water-soluble organic carbon (WSOC) in PM2.5 were made between May 5 and September 25, 2010, on a six-day interval basis, at the Metropolitan Area Air Pollution Monitoring Supersite. A macro-porous XAD7HP resin was used to separate hydrophilic and hydrophobic WSOC. Compounds that penetrate the XAD7HP column are referred to hydrophilic WSOC, while those retained by the column are defined as hydrophobic WSOC. Laboratory calibrations using organic standards suggest that hydrophilic WSOC includes lowmolecular aliphatic dicarboxylic acids and carbonyls with less than 4 or 5 carbons, amines, and saccharides. While the hydrophobic WSOC is composed of compounds of aliphatic dicarboxylic acids with carbon numbers larger than 4~5, phenols, aromatic acids, cyclic acid, and humic-like Suwannee River fulvic acid. Over the entire study period, total WSOC accounted for on average 48% of OC, ranging from 32 to 65%, and hydrophilic WSOC accounted for on average 30.5% (9.3~66.7%) of the total WSOC. Based on the previous results, our measurement result suggests that significant amounts of hydrophobic WSOC during the study period were probably from primary combustion sources. However, on June 9 when 1-hr highest ozone concentration of 130 ppb was observed, WSOC to OC was 0.61, driven by increases in the hydrophilic WSOC. This result also suggests that processes, such as secondary organic aerosol formation, produce significant levels of hydrophilic WSOC compounds that add substantially to the fine particle fraction of the organic aerosol.

Comparisons of obesity assessments in over-weight elementary students using anthropometry, BIA, CT and DEXA

  • Yu, Ok-Kyeong;Rhee, Yang-Keun;Park, Tae-Sun;Cha, Youn-Soo
    • Nutrition Research and Practice
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • Obesity was characterized in Korean elementary students using different obesity assessment tests on 103 overweight elementary students from three schools of Jeonbuk Province. The body mass index (BMI) and obesity index (OI) were compared, and the data using DEXA and CT were compared with the data using BIA and a tape measure. The results of this study are as follows: first, 27 students who were classified as obese by OI were classified as overweight by BMI, and 3 students who were classified as standard weight by BMI were classified as overweight by OI. Secondly, by DEXA and BIA measurements, there was 1.51% difference in body fat percentage (boys 1.66%, girls 1.17%) and the difference in body fat mass between boys and girls was 0.77 kg (boys 0.85 kg, girls 0.59 kg), but those differences in body fat percentage and mass were not statistically significant. Thirdly, the average total abdominal fat (TAF) measured by CT scans of obese children was more significantly related with subcutaneous fat (r = 0.983, P < 0.01) than visceral fat (r = 0.640, P < 0.01). Also, TAF were highest significant with waist circumference by a tape measure (r = 0.744, P < 0.01). In summary, as there are some differences of assessment results between two obesity test methods (BMI, OI), we need more definite standards to determine the degree of obesity. The BIA seems to be the most simple and effective way to measure body fat mass, whereas waist/hip ratio (WHR) using a tape measurer is considered to be the most effective method for assessing abdominal fat in elementary students.

A LATERAL CEPHALOMETRIC STUDY OF 10-YEAR-OLD CHILDREN WITH NORMAL OCCLUSION (10세 정상교합 아동의 측모두부방사선 계측학적 연구)

  • Ju, Chan-Hee;Kim, Seon-Mi;Yang, Kyu-Ho;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.280-290
    • /
    • 2012
  • This study was performed to establish the lateral cephalometric standards of Korean children for diagnosis of antero-posterior and vertical discrepancies of maxillofacial region. The lateral cephalometric radiographs were taken from 100 Korean children with normal occlusion, and then 15 measurements were statistically analysed. The results of this study were as follows : 1. Maxillary length of males was significantly greater than that of females (p < 0.05). There was strong correlation between maxillary and mandibular length (r = 0.625(M), 0.574(F)). 2. Lower facial height of males was significantly greater than that of females (p < 0.05). Furthermore, there was strong correlation between total facial height and upper facial height (r = 0.405(M), 0.417(F)) and very strong correlation between total facial height and lower facial height (r = 0.763(M), 0.787(F)). 3. All measurements for dento-alveolar relation showed no statistically significant sex difference. Maxillary length showed strong correlation with mandibular plane - lower incisor (r = 0.474(M), 0.426(F)) and mandibular plane - lower molar (r = 0.488(M), 0.499(F)).

Characterization of Annual PM2.5 and PM10 Concentrations by Real-time Measurements in Cheonan, Chungnam (실시간 측정을 통한 천안시 대기 중 연간 PM2.5, PM10 농도 특성 조사)

  • Heo, Jung-Hyuk;Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.445-450
    • /
    • 2012
  • From 2015, PM2.5 standards will be added to Korean national ambient air quality standards. To characterize PM2.5 levels in Cheonan, annual PM2.5 concentrations along with PM10 concentrations were investigated between February 2010 and January 2011 using a dust monitor. The annual PM2.5 concentration was $40.45{\mu}g/m^3$ and over the standards($25{\mu}g/m^3$). The daily average PM2.5 concentrations ranged from 2.43 to $178.84{\mu}g/m^3$, and 26% days exceeded the daily PM2.5 standard($50{\mu}g/m^3$). During the same periods, only 11% days exceeded the daily PM10 standard, showing that PM2.5 were more concerning levels than PM10. Seasonal variations showed the highest concentrations in spring and winter, and lowest concentration in summer due to heavy rain fall. Changes in PM2.5 concentrations during the day were remarkable and showed the highest concentrations in commuting periods. The results indicated that the concentrations of PM2.5 in Cheonan were at the concerning level, and mainly from the mobile sources.

Co Ion-implanted GaN and its Magnetic Properties

  • Kim, Woo-Chul;Kang, Hee-Jae;Oh, Suk-Keun;Shin, Sang-Won;Lee, Jong-Han;Song, Jong-Han;Noh, Sam-Kyu;Oh, Sang-Jun;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2006
  • $2-\mu{m}$ thick GaN epilayer was prepared, and 80 KeV $Co^{-}$ ions with a dose of $3X10^{16}\;cm^{-2}$ were implanted into GaN at $350^{\circ}C$. The implanted samples were post annealed at $700^{\circ}C$. We have investigated the magnetic and structural properties of Co ion-implanted GaN by various measurements. HRXRD results did not show any peaks associated with second phase formation and only the diffraction from the GaN layer and substrate structure were observed. SIMS profiles of Co implanted into GaN before and after annealing at $700^{\circ}C$ have shown a projected range of $\sim390\AA$ with 7.4% concentration and that there is little movement in Co. AFM measurement shows the form of surface craters for $700^{\circ}C$-annealed samples. The magnetization curve and temperature dependence of magnetization taken in zero-field-cooling (ZFC) and field-cooling (FC) conditions showed the features of superparamagnetic system in film. XPS measurement showed the metallic Co 2p core levels spectra for $700^{\circ}C$-annealed samples. From this, it could be explained that magnetic property of our films originated from Co magnetic clusters.

Simultaneous Determination of Tryptophan and Tyrosine by Spectrofluorimetry Using Multivariate Calibration Method (다변량 분석법을 이용한 Tryptophan과 Tyrosine의 형광분광법적 정량)

  • Lee, Sang-Hak;Park, Ju-Eun;Son, Beom-Mok
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.309-317
    • /
    • 2002
  • A spectrofluorimetric method for the simultaneous determination of amino acids (tryptophan and tyrosine) based on the application of multivariate calibration method such as principal component regression and partial least squares (PLS) to luminescence measurements has been studied. Emission spectra of synthetic mixtures of two amino acids were obtained at excitation wavelength of 257 ㎚. The calibration model in PCR and PLS was obtained from the spectral data in the range of 280-500 ㎚ for each standard of a calibration set of 32 standards, each containing different amounts of two amino acids. The relative standard error of prediction ($RSEP_a$) was obtained to assess the model goodness in quantifying each analyte in a validation set. The overall relative standard error of prediction ($RSEP_m$) for the mixture obtained from the results of a validation set, formed by 6 independent mixtures was also used to validate the present method.

Development and Characterization of an Atmospheric Turbulence Simulator Using Two Rotating Phase Plates

  • Joo, Ji Yong;Han, Seok Gi;Lee, Jun Ho;Rhee, Hyug-Gyo;Huh, Joon;Lee, Kihun;Park, Sang Yeong
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.445-452
    • /
    • 2022
  • We developed an adaptive optics test bench using an optical simulator and two rotating phase plates that mimicked the atmospheric turbulence at Bohyunsan Observatory. The observatory was reported to have a Fried parameter with a mean value of 85 mm and standard deviation of 13 mm, often expressed as 85 ± 13 mm. First, we fabricated several phase plates to generate realistic atmospheric-like turbulence. Then, we selected a pair from among the fabricated phase plates to emulate the atmospheric turbulence at the site. The result was 83 ± 11 mm. To address dynamic behavior, we emulated the atmospheric disturbance produced by a wind flow of 8.3 m/s by controlling the rotational speed of the phase plates. Finally, we investigated how closely the atmospheric disturbance simulation emulated reality with an investigation of the measurements on the optical table. The verification confirmed that the simulator showed a Fried parameter of 87 ± 15 mm as designed, but a little slower wind velocity (7.5 ± 2.5 m/s) than expected. This was because of the nonlinear motion of the phase plates. In conclusion, we successfully mimicked the atmospheric disturbance of Bohyunsan Observatory with an error of less than 10% in terms of Fried parameter and wind velocity.