• 제목/요약/키워드: National Power

검색결과 19,147건 처리시간 0.04초

제주계통의 전압조정을 위한 MMC-HVDC 시스템 응용 (Application of MMC-HVDC System for Regulating Grid Voltage Based on Jeju Island Power System)

  • 왓나우덩;김일환;이도헌;김호찬
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.494-502
    • /
    • 2014
  • This paper presents a control method of the modular multilevel converter - high-voltage direct current (MMC-HVDC) system to regulate grid voltage on the basis of the Jeju Island power system. In this case, the MMC-HVDC system is controlled as a static synchronous compensator (Statcom) to exchange the reactive power with the power grid. The operation of the MMC-HVDC system is verified by using the PSCAD/EMTDC simulation program. The Jeju Island power system is first established on the basis of the parameters and measured data from the real Jeju Island power system. This power system consists of two line-commutated converter - high-voltage direct current (LCC-HVDC) systems, two Statcom systems, wind farms, thermal power plants, transformers, and transmission and distribution lines. The proposed control method is then applied by replacing one LCC-HVDC system with a MMC-HVDC system. Simulation results with and without using the MMC-HVDC system are compared to evaluate the effectiveness of the control method.

고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발 (Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System)

  • 이현우;박영균;이진한;정상현;박철우
    • 전자공학회논문지
    • /
    • 제53권7호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 고조파로 전압과 전류가 왜곡된 상황에서 정확하게 기본파의 역률을 측정할 수 있는 방법을 제안한다. 제안한 역률 계측 방법에서는 전압과 전류를 DQ회전좌표계로 변환한 후 유효전력과 무효전력을 계산하여 역률값을 구하게 된다. 기존의 역률 계측방법과 제안한 방법을 수식적으로 비교하여 제시하고, 제안한 방법은 전압과 전류 모두 고조파 왜곡된 상황에서도 기본파의 역률을 정확하게 계측할 수 있는 것을 MATLAB을 이용한 모의실험에서 확인한다. 제안한 역률 계측방법을 자동역률제어장치에 적용할 경우 고조파 왜곡 환경에서 역률 보상 성능을 최대화 할 수 있다. 그 결과 수용가에서는 역률 개선을 통한 전기료 감소, 선로손실 감소, 부하 용량 증대 효과가 기대된다. 특히 발전 사업가 측에서는 역률 보상 성능의 향상으로 송전 여유 용량 확보와 발전량 절감이 가능하다.

Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections

  • Jung, Ga-Eun;Dinh, Minh-Chau;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.60-64
    • /
    • 2018
  • As the offshore wind farms increase, interest in the efficient power system configuration of submarine cables is increasing. Currently, transmission system of the offshore wind farm uses almost AC system. High temperature superconducting (HTS) power cable of the high capacity has long been considered as an enabling technology for power transmission. The HTS cable is a feasible way to increase the transmission capacity of electric power and to provide a substantial reduction in transmission losses and a resultant effect of low CO2 emission. The HTS cable reduces its size and laying sectional area in comparison with a conventional XLPE or OF cable. This is an advantage to reduce its construction cost. In this paper, we discuss the economic feasibility of the 22.9 kV HTS power cable and the conventional AC power cables for an offshore wind farm connections. The 22.9 kV HTS power cable cost for the offshore wind farm connections was calculated based on the capital expenditure and operating expense. The economic feasibility of the HTS power cable and the AC power cables were compared for the offshore wind farm connections. In the case of the offshore wind farm with a capacity of 100 MW and a distance of 3 km to the coast, cost of the 22.9 kV HTS power cable for the offshore wind farm connections was higher than 22.9 kV AC power cable and lower than 70 kV AC power transmission cable.

박형 자기소자를 이용한 AC-PDP 전원회로의 설계 및 제작 (Design and Implementation of AC-PDP Power Supply using Planar Magnetic Components)

  • 김명수;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.677-681
    • /
    • 2004
  • This paper presents the design and implementation of a low-profile power supply developed for AC-PDP application systems. In the proposed power supply, planar magnetics and SMD devices are integrated into advanced power conversion techniques to implement a low-profile power supply applicable to most AC-PDP application systems. Engineering details on the design and fabrication of planar magnetic components are presented. The performance of the prototype power supply is also demonstrated to validate the application potentials of the proposed power supply.

  • PDF

Dynamic Power Management Structure for Energy Harvesting Pervasive Computing System

  • Bae, Hyeoungho;Kim, Dong-Sung
    • 대한임베디드공학회논문지
    • /
    • 제1권1호
    • /
    • pp.1-7
    • /
    • 2006
  • In this paper, a novel power management structure for an energy harvesting pervasive system is proposed. The system considers the power state of each subsystem to assign proper power sources. The switch matrix structure utilizes each power source to reduce the peak current of the battery. The power management structure can be interfaced to an embedded system power supply without significant design change.

  • PDF

국제 열핵융합실험로 펄스전원계통의 무효전력보상기 검증 (Reactive Power Compensator for Pulsed Power Electric Network of International Thermonuclear Experimental Reactor)

  • 조현식;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.290-295
    • /
    • 2015
  • Analysis and verification of reactive power compensator (RPC) for ITER pulsed power electric network (PPEN) are described in this paper. The RPC system is rated for a nominal power of 250 Mvar necessary to comply with the allowable reactive power limit value from the grid 200 Mvar. This system is currently under construction and is based on static var compensation technology with a thyristor-controlled reactor and a harmonic filter. The RPC minimizes reactive power from grid using prediction of reactive power consumption of AC-DC converters. The feasibility of the reactive power compensation was verified by assembling a real controller and implementing ITER PPEN in the real time digital simulator for the hardware-in-loop facility. When maximum reactive power is reached, grid voltage is stabilized and maximum reactive power decreased from 120 Mvar to 40 Mvar via the reactive power prediction method.

전력계통의 전압안정도향상을 위한 감시제어시스템 개발 (A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System)

  • 이현철;정기석;박지호;백영식
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

Design of High Efficiency CMOS Class E Power Amplifier for Bluetooth Applications

  • Chae Seung Hwan;Choi Young Shig;Choi Hyuk Hwan;Kim Sung Woo;Kwon Tae Ha
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.499-502
    • /
    • 2004
  • A two-stage Class E power amplifier operated at 2.44GHz is designed in 0.25-$\mu$m CMOS process for Class-l Bluetooth application. The power amplifier employs c1ass-E topology to exploit its soft-switching property for high efficiency. A preamplifter with common-mode configuration is used to drive the output-stage of Class-E type. The amplifier delivers 20-dBm output power with 70$\%$ PAE (power -added-efficiency) at 2-V supply voltage.

  • PDF

NILRADICALS OF POWER SERIES RINGS AND NIL POWER SERIES RINGS

  • HUH, CHAN;KIM, CHOL ON;KIM, EUN JEONG;KIM, HONG KEE;LEE, YANG
    • 대한수학회지
    • /
    • 제42권5호
    • /
    • pp.1003-1015
    • /
    • 2005
  • Klein proved that polynomial rings over nil rings of bounded index are also nil of bounded index; while Puczylowski and Smoktunowicz described the nilradical of a power series ring with an indeterminate. We extend these results to those with any set of commuting indeterminates. We also study prime radicals of power series rings over some class of rings containing the case of bounded index, finding some examples which elaborate our arguments; and we prove that R is a PI ring of bounded index then the power series ring R[[X]], with X any set of indeterminates over R, is also a PI ring of bounded index, obtaining the Klein's result for polynomial rings as a corollary.

변압기를 이용한 저가형 단일형 PDP 구동회로에 대한 연구 (A study of simple PDP driver architecture using the transformer network)

  • 김우섭;신종원;채수용;현병철;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.63-65
    • /
    • 2007
  • 본 논문에서는 변압기를 이용한 단일형 전력회수회로 및 구동 회로를 제안한다. 제안된 회로는 변압기를 이용하여 회수 콘덴서 대체 및 다이오드를 제거하여 전력회수회로를 단순화 한다. 양전원을 이용하여 기존 구동회로의 소거방전시 필요한 주 경로상 직렬 단방향 스위치도 제거된다. 모의 실험을 통해 이용하여 제안된 회로의 타당성을 검토한다.

  • PDF