• Title/Summary/Keyword: NaI(TI)

Search Result 85, Processing Time 0.026 seconds

Design of Wide-Range radiation measurement system using GM Tube and NaI(TI) Detector (GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계)

  • Ra, Seung-Tak;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.146-149
    • /
    • 2017
  • In this paper, we propose a wide-range radiation measurement system using GM Tube and NaI(TI) detector. The proposed system is designed as a small module optimized to control and count the detector signal of NaI(Tl) Detector and GM Tube. The radiation dose is measured in a wide-range 0.1uSv/h to 10mSv/h in conjunction with two detectors, and two detectors operate simultaneously at 10uSv/h to 100uSv/h, where the measurement interval overlaps. The radiation dose was selected using a wide-range radiation measurement algorithm that controls the on/off function of the detector in the appropriate interval for the overlapped radiation measurable interval. In order to evaluate the performance of the proposed system, it has been confirmed that the measurement uncertainty of each section is measured as ${\pm}7.5%$ and it operates normally under ${\pm}15%$ of the international standard.

Monte Carlo Simulations of Detection Efficiency and Position Resolution of NaI(TI)-PMT Detector used in Small Gamma Camera (소형 감마카메라 제작에 사용되는 NaI(TI)- 광전자증배관 검출기의 민감도와 위치 분해능 특성 연구를 위한 몬테카를로 시뮬레이션)

  • Kim, Jong-Ho;Choi, Yong;Kim, Jun-Young;Im, Ki-Chun;Kim, Sang-Eun;Choi, Yeon-Sung;Joo, Kwan-Sik;Kim, Young-Jin;Kim, Byung-Tae
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 1997
  • We studied optical behavior of scintillation light generated in NaI(TI) crystal using Monte Carlo simulation method. The simulation was performed for the model of NaI(TI) scintillator (size: 60 mm ${\times}$ 60 mm ${\times}$ 6 mm) using an optical tracking code. The sensitivity as a function of surface treatment (Ground, Polished, Metal-0.95RC, Polished-0.98RC, Painted- 0.98RC) of the incident surface of the scintillator was compared. The effects of NaI(TI) scintillator thickness and the refractive index of light guide optically coupling between the NaI(TI) scintillator and photomultiplier tube (PMT) were simulated. We also evaluated intrinsic position resolution of the system by calculating the spread of scintillation light generated. The sensitivities of the system having the surface treatment of Ground, Polished, Metal-0.95RC, Polished-0.98RC and Painted-0.98RC were 70.9%, 73.9%, 78.6%, 80.1% and 85.2%, respectively, and the surface treatment of Painted-0.98RC allowed the highest sensitivity. As increasing the thickness of scintillation crystal and light guide, the sensitivity of the system was decreased. As the refractive index of light guide increases, the sensitivity was increased. The intrinsic position resolution of the system was estimated to be 1.2 mm in horizontal and vertical directions. In this study, the performance of NaI(TI)-PMT detector system was evaluated using Monte Carlo simulation. Based on the results, we concluded that the NaI(TI)-PMT detector array is a favorable configuration for small gamma camera imaging breast tumor using Tc-99m labeled radiopharmaceuticals.

  • PDF

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector (플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발)

  • Kwak, Dong-Hoon;Ko, Tae-Young;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.638-644
    • /
    • 2018
  • In this paper, we develop a measurement system that uses 3D Scintillator and NaI(TI) Detector to 3-dimensionally identify the location of multiple radiation sources in moving vehicle loads. The radiation measurement system consists of radiation measurement (plastic scintillator), 2-channel Pulse Counter Board, nuclide analysis (NaI(TI) detector) and 1 channel MCA Board. The source locator algorithm calculates the coordinate value of the ratio of the CPS value($1/r^2$) of the source according to the angle(${\theta}$) in inverse proportion to the square of the distance(X, Y) through the SVM classification. The coordinate values are input every predetermined period of the spectrum, and after analyzing the spectrum per unit cycle, the position of the nuclide at the time is calculated by determining whether or not the nuclide is present in the remaining part except for the background area. As a result of the position discrimination test, the error within the international standard of ${\pm}1m$ was shown. Thus, the utility of the proposed system has been demonstrated.

Ferroelectric Phase Transition Behavior in $(Na_{1/2}Bi_{1/2})TiO_3-PbTiO_3$ System ($(Na_{1/2}Bi_{1/2})TiO_3-PbTiO_3$ 고용체의 강유전 상전이 거동)

  • 홍국선;조서용;박승익
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.8
    • /
    • pp.915-921
    • /
    • 1995
  • The morphotropic phase boundary and phase transitions of the solid solutiion system, (1-x)(Na1/2Bi1/2)TiO3-PbTiO3+xPbTiO3 were studied by investigating changes in crystal structure, variations in permittivity with temperature, and calorimetric behavior. It was observed that the morphotropic phase boundary (MPB) of this solid solutiion system was at near 14 mol% of PbTiO3. Compositions containing less than 10mol% PbTiO3 (x<0.1) exhibited a phase transition, i.e. ferroelectric rhombohedrallongrightarrowparaelectric paraelectric cubic, with increasing temperature. Composition containing more than 14 mol% PbTiO3 (x 0.14) showed a phase transition from ferroelectric tetragonal to paraelectric cubic. In the composition range of 0.1$\varepsilon$ (T) curve, which coincided with a phase transition from ferroelectric rhombohedral to an intermediate phase, was also found.

  • PDF

Comparing Resistances to Pitting Corrosion of Additive Manufactured Ti-6Al-4V Alloys in NaCl and NaBr Aqueous Solutions (NaCl과 NaBr수용액에서 적층가공으로 제조된 Ti-6Al-4V 합금의 공식 저항성 비교)

  • Seo, Dong-Il;Lee, Jae-Bong
    • Corrosion Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.110-116
    • /
    • 2019
  • Resistances to pitting corrosion of additive manufactured (AM) Ti-6Al-4V alloys in 0.6 M NaBr and 0.6 M NaCl aqueous solutions were compared using micro-droplet cell techniques. With respect to the pitting corrosion resistance, this study focused on two different types of halide anions in aqueous solutions, i.e. $Br^-$ and $Cl^-$. The differences between $Br^-$ and $Cl^-$ halide anions for breakdown on passive films of AM Ti-6Al-4V alloy were explained using Langmuir adsorption model with their equilibrium adsorption coefficients. The results of the analysis showed that the lower resistance to pitting potential of AM Ti-6Al-4V alloy in $Br^-$ aqueous solution was attributed to the higher equilibrium adsorption coefficient of Br-. In addition, micro-electrochemical test results showed that the pitting corrosion resistance of dark grains in additive manufactured Ti-6Al-4V alloy was lower as compared to that of bright grains due to the larger volume of ${\alpha}^{\prime}$ phase that caused the susceptibility to pit initiation.

Preparation and characterization of new perovskite compounds $(Na_{0.5}Sr_{0.5})(M_{0.5}N_{0.5})O_3$(MTi,Zr N=Ta,Nb)

  • Chung, Hoon-Taek;Tetsuro Nakamura;Mitsuru Itoh
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.06a
    • /
    • pp.49-51
    • /
    • 1997
  • New complex perovskite compounds (Na0.5Sr0.5)(Ti0.5Nb0.5)O3, (Na0.5Sr0.5)(Zr0.5Ti0.5)O3 and (Na0.5Sr0.5)(Ti0.5Ta0.5)O3 have been prepared. The crystal structures of these compounds were determined by powder X-ray Rietveld analysis. The crystal structure of (Na0.5Sr0.5)(Ti0.5Nb0.5)O3 and (Na0.5Sr0.5)(Zr0.5Ta0.5)O3 was Pmmn, and that of (Na0.5Sr0.5)(Ti0.5Nb0.5)O3 was I4/mmm. All these compounds showed the superstructure due to the oxygen octahedron distortion. The selected bond distances and bond angles were calculated by the OFFER. The octahedron distortion for each sample, which was measured from the bond distances and bond angles, showed the following order: (Na0.5Sr0.5)(Z0.5Ta0.5)O3> (Na0.5Sr0.5)(Ti0.5Nb0.5)O3 > (Na0.5Sr0.5)(Ti0.5Ta0.5)O3. Dielectric properties were measured for the samples. In this study, the crystal structure and dielectric properties of the new complex perovskite structures and discussed.

  • PDF

Biomimetic Deposition of Apatite on Zr-1Nb and Ti-6Al-4V

  • Kim, J.;Choi, Y.C.;Kim, H.S.;Hong, S.I.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1089-1090
    • /
    • 2006
  • Biomimetic apatite deposition behaviors on Zr-1Nb and Ti-6Al-4V plate with various surface conditions were examined. Both alloys were polished with abrasive papers to have different roughness and some of them were treated in NaOH before exposition in simulated body fluid. NaOH treatment was found to enhance the deposition rate of apatite on Ti-6Al-4V significantly. On the other hand, the deposition rate of Zr-1Nb was not influenced by NaOH treatment. Without NaOH treatment, the polished Zr-1Nb with abrasive paper was found to induce more apatite nucleation than the polished Zr-6Al-4V.

  • PDF

A Study on the Ouabain-induced Transient Inward Current(TI) in the Rabbit Sinoatrial Node (동방결절에서 Ouabain에 의하여 발생하는 일과성 내향전류(TI)에 관한 연구)

  • Choi, Jung-Yun;Hong, Chang-Yee;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.19 no.2
    • /
    • pp.101-111
    • /
    • 1985
  • Transient inward current (TI) was studied by the two micro-electrode voltage clamp technique in the sinoatrial node of the rabbit. The author confirmed that in $10^{-6}$ M ouabain TI was found in the SA node and investigated the effects of ions, $(Na^+,\;K^+,\;Ca^{2+})$, $\beta-agonist$ (isoprenaline), local anesthetics (quinidine, lidocaine) and Ca-blockers ($Co^{2+}$, verapamil, diltiazem) on the TI recorded during depolarizing voltage clamp pulses to -40 and -20 mV. The results obtained were as follows ; 1) $10^{-6}M$ ouabain increased the frequency of sinus action potential and decreased the amplitude, especially overshoot of action potential. TI was induced by the depolarizing voltage clamp Pulses and the magnitude of the slow inward current (isi) decreased and the time course was slowed by the same depolarizing pulses. 2) 30% $Na^{+}$ and 24mM $K^+$ decreased by $10^{-6}M$ ouabain and 6 mM $Ca^{2+}$ and $10^{-7}M$ isoprenaline increased TI, $i_{si}$ and current oscillations. 3) Quinidine $(5\times10^{-7}M)$ reduced TI and $i_{si}$ but lidocaine $(10^6\;-10^5M)$ didn't reduced or increase TI. Current oscillations increased and isi decreased by lidocaine. 4) Ca-blockers decreased the amplitude and the frequency of sinus action potential. TI and $i_{si}$ decreased significantly but were not abolished completely at the concentrations used in this experiment. Verapamil and diltiazem had inhibitory action on TI in $2\times10^{-7}M$ concentration and showed very slow recovery after wasting out with normal Tyrode solution.

  • PDF

Pyrolytic Conversion of Blended Precursors into Ti-Al-N Ceramic Composites

  • Cheng, Fei;Sugahara, Yoshiyuki;Kuoda, Kazuyuki
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.32-36
    • /
    • 2000
  • Pyrolytic preparations of Ti-Al-N ceramics from three blended precursors were investigated. The precursors were prepared stirring ($HA1N^{i}Pr_m$ and an aminolysis product of $Ti(NMe_2)_4$ with $MeHNCH_2CH_2$NHMe in $C_6/H_6$ . IR and $^1H\;NMR $analyses suggested that essentially no Ti-N-Al bonds were present in the precursors. Pyrolysis of the precursors under $NH_3-N_2$led to the formation of brown solids with ceramic yields of about 30%, and the Ti-Al ratios in the pyrolyzed products were close to those of the precursors. XRD analysis of the pyrolyzed product from the precursor with Ti:Al=5:1 indicated the formation of a NaCl-type compound as the only crystalline phase. Pyrolysis of the precursor with Ti:Al=2:1 led to the formation of AlN besides the major NaCl-type compound. A ceramic composite containing AlN and the NaCl-type compound was formed by pyrolysis of the precursor with Ti:Al=1:2.

  • PDF