• Title/Summary/Keyword: NOx/SOx removal

Search Result 49, Processing Time 0.037 seconds

A Study on the Removal of SOx and NOx Using Catalytic Ceramic Filters (촉매담지 세라믹 필터를 이용한 황산화물과 질소산화물의 제거에 관한 연구)

  • 홍민선;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.455-464
    • /
    • 1998
  • Removal teals of Soxmox were performed using low density ceramic filters doped with various catalysts. Disc type (50 mmO.Dx10 mmt) low density ceramic filters were doped with three different catalysts such as Cu to remove SOx and NOx, and Mn and Co to remove NOx. The air permeabilities and specific surface areas were 40~50cc/min.cm2.cmH2O and 4.1~8.88 m2/g, respectively. Also, the peak pore sizes of catalyst support were 3~5nm. Tests were focused to search optimum operating temperatures for different catalysts. It was found that as the CuO content increases, SOx removal efficiency was increased. NOx removal efficiencies for Mn, Cu and Co, were 85% at 30$0^{\circ}C$, 90% at 40$0^{\circ}C$ and 90% at 45$0^{\circ}C$, respectively.

  • PDF

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Plasma Chemical Reaction (플라즈마 화학반응에 의한 연소가스 중 NOx. SOx 동시제거 특성)

  • 박재윤;고용술;이재동;손성도;박상현;고희석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.406-409
    • /
    • 1999
  • Experimental Investigations were carried out to remove NOx, SOx simultaneously from simulated flue gas[NO(0.02%)-SO$_2$(0.08%)-$CO_2$-Air-$N_2$] by using a plasma chemical reaction. Ammonia gas(14.81%) balanced by argon was diluted by all and was Introduced to mall simulated flue gas duct through NH$_3$ Injection system which is in downstream of reactor. The NH$_3$ molecular ratio(MR) was determined based on (NH3) to [NO+S0$_2$]. MR is 1, 1.5, 2.5. The NOx removal rate significantly increased with increasing NaOH bubble quantity. The SO$_2$ removal rate was not significantly effected by applied voltage, however it fairly Increased with increasing NH$_3$ molecule ratio. By-product aerosol particle was observed by XRD(X-ray diffraction) after sampling, The NOx, SOx removal rates, when H2O vapour bubbled by dry all was injected to plasma reactor, were better than those of other cases. When aqueous NaOH solution(20%) bubbled by 2.5( ι /min) of $N_2$ and 0.5 ( ι /min) NH$_3$(MR=1.5) were injected to simulated flue gas, The NOx. SOx removal rate was 95 ~ 100[%]

  • PDF

Reaction Characteristics of SOx/NOx Removal Using CuO/γ-Al2O3 Sorbent/Catalyst (CuO/γ-Al2O3 흡수제/촉매를 이용한 SOx/NOx 제거 반응특성)

  • Yoo, Kyung Seun;Kim, Sang Done
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.671-678
    • /
    • 2000
  • Reaction characteristics of simultaneous removal of SOx and NOx have been investigated in a thermogravimetric analyzer and tubular fixed bed reactor using the $CuO/{\gamma}-Al_2O_3$ sorbent/catalyst. Sulfur removal capacity of $CuO/{\gamma}-Al_2O_3$ sorbent/catalyst is largely enhanced above both the temperature of $450^{\circ}C$ and the loading of 6wt% due to the participation of alumina support in a sulfation reaction. The NO reduction efficiency of 8wt% $CuO/{\gamma}-Al_2O_3$ sorbent/catalyst shows the maximum value at $370^{\circ}C$ and then decreases with the increase of reaction temperature due to the oxidation of $NH_3$ gas. The presence of sulfate on the surface of sorbent/catalyst enhances the optimum reaction temperature showing the maximum deNOx efficiency. In the simultaneous removal of SOx and NOx at $250^{\circ}C$. deNOx activity of $CuO/{\gamma}-Al_2O_3$ sorbent/catalyst is rapidly decreased due to the formation of ammonium salts such as $NH_4HSO_4$. In the simultaneous removal reaction of SOx and NOx, the optimum temperature showing the maximum deNOx efficiency increases to $400^{\circ}C$ due to the presence of $SO_2$ gas.

  • PDF

The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain (연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성)

  • Park, J.Y.;Koh, Y.S.;Lee, J.D.;Song, W.S.;Park, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

A study about NOx. SOx removal using non-thermal plasma (비열 플라즈마를 이용한 NOx, SOx 제거에 대한 연구)

  • Sun, Sang-Kweon;Woo, In-Sung;Lee, Byung-Ki;Sung, Nak-Jin;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1596-1597
    • /
    • 1998
  • This study is an experiment using the non-thermal plasma for removal of NOx, SOx. This experimental setup is made up the superposing discharge electrode in order to increase the removal. Both electrode are plate and niddle electrode, back of plate installed the lower electrode making pure silver. The result of the superposing discharge is thought that the rate of removal increase by means of rising effect. This is studied the property to the U.V irradiation and temperature dependence of the flue gas.

  • PDF

Simultaneous Removal of NOx/SOx by Catalyst-loaded Cordierite Porous Filter (촉매 담지 코디어라이트 다공성 필터의 NOx/SOx 동시제거에 대한 연구)

  • Lee, Shi-Hee;Chung, Koo-Chun;Kim, Jee-Woong;Shin, Min-Chul;Lee, Hee-Soo
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.256-262
    • /
    • 2002
  • After porous filters were manufactured using cordierite powder whose mean paricle size was 200${\mu}m$, they were loaded with catalysts such as $V_2O_5$, CuO and $LaCoO_3$ by vacuum impregnation method. And the NOx/SOx simultaneous removal efficiency was measured by passing NO and $SO_2$ through catalyst-loaded ceramic filters. The cordierite porous filters had the apparent porosity of 61.6%, the compressive strength of 12.3 MPa and the pressure drop of 147 pa at the face velocity of 5 cm/sec. According to the analysis of NO/$SO_2$ simultaneous removal efficiency, perovskite $LaCoO_3$ catalyst was the most efficient for the simultaneous NO and $SO_2$ removal. The $LaCoO_3$ catalyst-loaded filter could remove more than 90% for NO and more than 80% for $SO_2$.