Abstract
Experimental Investigations were carried out to remove NOx, SOx simultaneously from simulated flue gas[NO(0.02%)-SO$_2$(0.08%)-$CO_2$-Air-$N_2$] by using a plasma chemical reaction. Ammonia gas(14.81%) balanced by argon was diluted by all and was Introduced to mall simulated flue gas duct through NH$_3$ Injection system which is in downstream of reactor. The NH$_3$ molecular ratio(MR) was determined based on (NH3) to [NO+S0$_2$]. MR is 1, 1.5, 2.5. The NOx removal rate significantly increased with increasing NaOH bubble quantity. The SO$_2$ removal rate was not significantly effected by applied voltage, however it fairly Increased with increasing NH$_3$ molecule ratio. By-product aerosol particle was observed by XRD(X-ray diffraction) after sampling, The NOx, SOx removal rates, when H2O vapour bubbled by dry all was injected to plasma reactor, were better than those of other cases. When aqueous NaOH solution(20%) bubbled by 2.5( ι /min) of $N_2$ and 0.5 ( ι /min) NH$_3$(MR=1.5) were injected to simulated flue gas, The NOx. SOx removal rate was 95 ~ 100[%]