Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Plasma Chemical Reaction

플라즈마 화학반응에 의한 연소가스 중 NOx. SOx 동시제거 특성

  • 박재윤 (경남대학교 전기공학과) ;
  • 고용술 (경남대학교 전기공학과) ;
  • 이재동 (경남대학교 전기공학과) ;
  • 손성도 (경남대학교 전기공학과) ;
  • 박상현 (경남대학교 전기공학과) ;
  • 고희석 (경남대학교 전기공학과)
  • Published : 1999.05.01

Abstract

Experimental Investigations were carried out to remove NOx, SOx simultaneously from simulated flue gas[NO(0.02%)-SO$_2$(0.08%)-$CO_2$-Air-$N_2$] by using a plasma chemical reaction. Ammonia gas(14.81%) balanced by argon was diluted by all and was Introduced to mall simulated flue gas duct through NH$_3$ Injection system which is in downstream of reactor. The NH$_3$ molecular ratio(MR) was determined based on (NH3) to [NO+S0$_2$]. MR is 1, 1.5, 2.5. The NOx removal rate significantly increased with increasing NaOH bubble quantity. The SO$_2$ removal rate was not significantly effected by applied voltage, however it fairly Increased with increasing NH$_3$ molecule ratio. By-product aerosol particle was observed by XRD(X-ray diffraction) after sampling, The NOx, SOx removal rates, when H2O vapour bubbled by dry all was injected to plasma reactor, were better than those of other cases. When aqueous NaOH solution(20%) bubbled by 2.5( ι /min) of $N_2$ and 0.5 ( ι /min) NH$_3$(MR=1.5) were injected to simulated flue gas, The NOx. SOx removal rate was 95 ~ 100[%]

Keywords