• Title/Summary/Keyword: NMR magnet

Search Result 62, Processing Time 0.029 seconds

Temperature dependency of magnetic field drifts of HTS pancake coils for NMR/MRI applications

  • Choi, Kyeongdal;Lee, Seyeon;Kim, Woo-Seok;Lee, Sang Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.44-47
    • /
    • 2013
  • We had proposed a winding method so called "Wind-and-Flip", which enables a persistent current operation of an HTS pancake coil without any electrical joint. In order to improve the magnetic field drift characteristics, a prototype HTS coil with the technique was fabricated, and tested under various temperatures. Because the coil doesn't have any electric terminals for current leads, an HTS background magnet was used to induce the persistent current in the coil by field cooling process. A conduction cooling system with a GM cryocooler was prepared to keep the operating temperatures of the prototype coil much below the 77 K. We investigated the magnetic field drift characteristics under the various operating temperatures by measuring the center magnetic field with a cryogenic Hall sensor. The persistent current mode operation at 20 ~ 50K showed a strong possibility of the winding technique for the application such as MRI or NMR.

Detection of Iron Nanoparticles using Nuclear Magnetic Resonance Relaxometry and Inverse Laplace Transform

  • Kim, Seong Min
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: Rapid detection of bacteria is very important in agricultural and food industries to prevent many foodborne illnesses. The objective of this study was to develop a portable nuclear magnetic resonance (NMR)-based system to detect foodborne pathogens (E. coli). This study was focused on developing a method to detect low concentrations of magnetic nanoparticles using NMR techniques. Methods: NMR relaxometry was performed to examine the NMR properties of iron nanoparticle mixtures with different concentrations by using a 1 T permanent magnet magnetic resonance imaging system. Exponential curve fitting (ECF) and inverse Laplace transform (ILT) methods were used to estimate the NMR relaxation time constants, $T_1$ and $T_2$, of guar gum solutions with different iron nanoparticle concentrations (0, $10^{-3}$, $10^{-4}$, $10^{-5}$, $10^{-6}$, and $10^{-7}M$). Results: The ECF and ILT methods did not show much difference in these values. Analysis of the NMR relaxation data showed that the ILT method is comparable to the classical ECF method and is more sensitive to the presence of iron nanoparticles. This study also showed that the spin-spin relaxation time constants acquired by a Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence are more useful for determining the concentration of iron nanoparticle solutions comparwith the spin-lattice relaxation time constants acquired by an inversion recovery pulse sequence. Conclusions: We conclude that NMR relaxometry that utilizes CPMG pulse sequence and ILT analysis is more suitable for detecting foodborne pathogens bound to magnetic nanoparticles in agricultural and food products than using inversion recovery pulse sequence and ECF analysis.

Development of 600-MHz 19F-7Li Solid-State NMR Probe for In-Situ Analysis of Lithium Ion Batteries

  • Jeong, Ji-Ho;Park, Yu-Geun;Choi, Sung-Sub;Kim, Yongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3253-3256
    • /
    • 2013
  • Lithium is a highly attractive material for high-energy-concentration batteries, since it has low weight and high potential. Rechargeable lithium-ion batteries (LIBs), which have the extremely high gravimetric and volumetric energy densities, are currently the most preferable power sources for future electric vehicles and various portable electronic devices. In order to improve the efficiency and lifetime, new electrode compounds for lithium intercalation or insertion have been investigated for rechargeable batteries. Solid-state nuclear magnetic resonance (NMR) is a very useful tool to investigate the structural changes in electrode materials in actual working lithium-ion batteries. To detect the in-situ microstructural changes of electrode and electrolyte materials, $^7Li-^{19}F$ double-resonance solid-state NMR probe with a static solenoidal coil for a 600-MHz narrow-bore magnet was designed, constructed, and tested successfully.

Development of a 1.8T HTS Insert Coil for High Field Magnet (고자장 자석용 1.8T HTS insert 코일 개발)

  • Bae, Joon-Han;Seong, Ki-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1035-1038
    • /
    • 2007
  • We designed and manufactured a 1.8T high temperature superconducting(HTS) insert coil for a NMR magnet operated at 4.2 K. Suitable HTS superconductor and HTS coil were carefully designed and developed. We have selected multi-filamentary Bi2223 conductor fabricated by American Superconductor Corporation(AMSC). The selected conductor consists of Bi2223 filaments of 55, silver stabilizer and stainless steel reinforcement tapes. Therefore, it shows good hoop strength as well as compression tolerance. The conductor has a tape cross-section of 0.31mm x 4.8mm. the Bi2223 conductor shows large anisotropy of critical current. The critical current of conductor in magnetic field parallel to the flat surface are much higher than that in magnetic field perpendicular. The HTS coil has an inner diameter of 78 mm, an outer diameter of 127 mm and a coil length of 600 mm. In this paper, the detailed design, fabrication and test results on the HTS insert coil are presented.

Operating characteristics of linear type magnetic flux pump (리니어타잎 초전도 전원장치의 동작특성)

  • Chung, Yoon-Do;Bae, Duck-Kweon;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.665-666
    • /
    • 2008
  • Inserted HTS (high temperature superconducting) coil is promisingly expected as a solution for achievement of higher fields such as GHz scale NMR magnet. However, HTS magnet causes persistent current decay in the persistent current mode and this decay should be compensated in order to keep stable magnetic field. As a solution for the decay in the HTS magnets, we proposed a new type superconducting power supply, i.e., linear type magnetic flux pump (LTMFP). The LTMFP mainly consists of DC bias coil, 3-phase AC coil and superconducting Nb foil. The compensating current in closed superconductive circuit can be easily controlled by the intensity of 3-phase AC current and its frequency. In this study, it has been investigated that the flux pump can effectively charge the current for various frequencies according to the different load magnets.

  • PDF

The Study on the Characteristics and Design Method of High-Tc Superconducting Persistent Current Switch (고온초전도 영구전류스위치의 특성 및 설계에 관한 연구)

  • 박상건;강형구;배덕권;윤용수;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.216-219
    • /
    • 2003
  • Persistent Current Switch (PCS) is used in many superconducting magnet system. To apply the high-Tc superconductor in superconducting machine such as motor, generator, MAGLEV, MRI and NMR, the study on the persistent current mode should be performed. Because persistent current mode provide best stability and homogeneous characteristics to the superconducting machine. To stabilize the superconductor system, it is important to estimate the length of PCS. If the proper length of PCS is too short, it cause serious injury to system in fault state. So we calculated the optimal length of PCS in this paper.

  • PDF

Fabrication and test of heater triggered persistent current switch using coated conductor tapes (Coated conductor를 이용한 히터트리거 방식의 영구전류 스위치의 제작과 실험)

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Yoon, Yong-Soo;Ko, Tae-Huk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2039-2040
    • /
    • 2006
  • Persistent current switch (PCS) system in NMR, MRI, MAGLEV and SMES has many advantages, such as uniformity and durability of magnetic field and reducing a thermal loss, which enable many superconducting application to operate effectively. This paper deals with fabrication and test of heater trigger persistent current switch using coated conductor (CC) which has high n-index, critical current independency from external magnetic field and adaptable selectivity of stabilizer. PCS system consists of magnet power supply for energizing current to a magnet, heater, switch and magnet using coated conductor tape. Finite element method (FEM) is used to simulate thermal quench (switching) characteristic and design heater trigger. With FEM simulation, optimal length of heater is calculated by temperature and time analysis. Fabrication of PCS system and test of heater trigger characteristic were performed and compared with simulation result. This paper would be the foundation of researches of superconducting switching application.

  • PDF

Estimation of the critical current of race-track HTS magnet considering angular dependency

  • Lee, Kyubong;Sim, Kideok;Lee, Changyoung;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.47-50
    • /
    • 2015
  • The high temperature superconducting (HTS) magnet has been developed for the high magnetic field applications such as NMR, MRI and other industrial machinery. In designing process of these HTS magnets, the accurate estimation on the critical current (Ic) is essential to predict and secure the electromagnetic performance. The critical current of 2G HTS tape has anisotropic Ic degradation characteristics with the application of magnetic field - angular dependency of critical current. It is known that the perpendicular magnetic field to the face of HTS tape makes dominant degradation on the critical current for conventional 2G HTS tape. However, recently developed 2G HTS tape has more complex characteristics due to the artificial pinning center. Therefore, the method for Ic estimation reflecting such characteristics of 2G HTS tape needs to be devised. The method considering the angular dependency is introduced in this paper. And the result of newly devised method is compared with that of previous method.

Design, fabrication and test of inside notched superconducting coil (내노치형 초전도 솔레노이드 마그네트의 설계.제작 및 평가)

  • Nah, Wan-Soo;Jin, Hong-Beom;Oh, Bong-Hwan;Kwon, Young-Kil;Oh, Sang-Soo;Cho, Jeon-Wook;Ha, Dong-Woo;Lee, Eon-Yong;Ryu, Kang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.63-65
    • /
    • 1994
  • In this paper, the design, fabrication and test of inside notched superconducting coil are described. The inside notched coil is one of the basic configurations, producing homogeneous magnetic field. This magnet is a primitive version of MRI or NMR magnet in Korea Electromagnetic Research Institute. To test the magnetic field distribution inside the magnet, a X-Z scanner was made and the homogeneity was about $1.8{\times}10^{-3}$in 5 cm dsv (Diameter of Spherical Volume).

  • PDF

A Prospect of the Superconductivity Research of the Industrial Application (초전도 산업응용기술의 연구동향 및 발전방향)

  • Kwon, Young-Kil
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.18-21
    • /
    • 1999
  • This paper is to present the general descriptions and their research trend of MRl/NMR which has already commercialized and also is more successful than any other applications of superconducting magnet, Superconducting Single Crystal Growing Equipment and Superconducting Magnetic Separation technology which are practically used in the related areas, and power electric application machine, which is the most effective and efficient one among the applications using high magnetic field. Therefore, it is hoped that this study will help to establish the ground of the industrial application of superconductivity in Korea.

  • PDF