• Title/Summary/Keyword: NIR camera

Search Result 71, Processing Time 0.024 seconds

The Akari two-color diagrams for AGB stars

  • Suh, Kyung-Won;Kwon, Young-Joo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.80.1-80.1
    • /
    • 2010
  • From the Akari observational data, we have cross-identified a major portion of AGB stars listed in the catalog of AGB stars presented by Suh & Kwon (2009). We have used the Akari-IRC (Infrared Camera) PSC (Point Source Catalogue; about 850,000 sources at 9 and $18\;{\mu}m$) and Akari-FIS (Far-infrared Surveyer) BSC (Bright Source Catalogue; about 440,000 sources at 65, 90, 140 and $160\;{\mu}m$) as well as the IRAS and NIR observational data to make various meaningful two-color diagrams for AGB stars. We compare them with the theoretical models with various dust shell model parameters and chemical compositions.

  • PDF

Estimating Black Hole Mass in Active Galactic Nuclei with Hydrogen Brackett lines

  • Kim, Do-Hyeong;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.32.2-32.2
    • /
    • 2010
  • Red dusty Active Galactic Nuclei (AGNs) are suspected to mid-stage between ULIRG and AGN phase. As well as, they are suspected that they have more than 50% of AGN population. To understand character of red AGN, Black Hole (BH) mass of red AGN is a key property and haven't measured by existing method such as reverberation mapping and single epoch method. So we still don't know their character and properties clearly. To estimate properties of red AGNs escape from effect of dust-obscuration, we have obtained Near InfraRed (NIR) spectra of 31 reverberation mapped AGNs and 49 Palomar-Green(PG) Quasi-Stellar Object (QSO) using the infrared camera (IRC) for AKARI with unique wavelength range 2.5-$5.0{\mu}m$. From this spectra, we measured the FWHM and luminosity of brackett ${\alpha}$, ${\beta}$ at 4.0, 2.6 micron meter for deriving new BH mass estimators based on the properties of Brackett line emission.

  • PDF

Development of early diagnosis method of damaged tree by pine wilt disease using Portable NIR camera (휴대용 근적외선 카메라를 이용한 소나무 재선충 피해목 조기탐지 방법개발)

  • Jung, Sung-Eun;Kim, Yoo-Seung;Noh, Byung-Yoon;Lee, Young-Won
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.14-19
    • /
    • 2008
  • 소나무 재선충에 감염되어 고사하는 소나무의 증가는 우리나라 산림에 심각한 위협이 되고 있다. 재선충은 매개 후 고사단계에 이르기까지 진행과 확산이 빨라 감염목이 발견되면 곧바로 임내에서 벌채 및 훈증 처리해야 하며 5${\sim}$6월에 감염되어 10${\sim}$11월에 육안으로 고사를 확인할 수 있다. 재선충에 의해 소나무가 고사되는 과정에서 식생활력도가 크게 감소하며 이러한 현상은 근적외선 영역에서 분광반사의 감소를 수반한다. 따라서 본 연구는 근적외선영역의 분광감소를 이용하여 재선충 피해목의 조기진단이 가능할 수 있다는 것에 착안하여 수행하였다. 근적외선영상 취득 방법으로 휴대가 간편한 근적외선 카메라를 이용하여 재선충 피해지역의 소나무림을 5월부터 11월까지 매월 촬영하였다. 이렇게 수집된 분광반사값으로부터 식생지수(Vegetation Index: VI)의 변화를 분석하였고, VI의 감소율로부터 소나무 재선충 감염목을 조기에 발견할 수 있다는 결과를 도출하였다.

  • PDF

The $2.5-5.0{\mu}m$ Spectra Atlas of Type 1 Active Galactic Nuclei with AKARI: Establishing the Black Hole Mass Estimator of Active Galactic Nuclei with Hydrogen Brackett Lines

  • Kim, Do-Hyeong;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.80.1-80.1
    • /
    • 2012
  • The $2.5-5.0{\mu}m$ spectrum of AGN was poorly understood due to the atmosphere effect beyond $2{\mu}m$. Nevertheless, the $2.5-5.0{\mu}m$ range includes several important lines, such as $Br{\beta}$ ($2.63{\mu}m$), $Br{\alpha}$ ($4.05{\mu}m$), PAH (3.3${\mu}m$) and many molecular or atomic lines. We compile $2.5-5.0{\mu}m$ spectra of 79 AGNs and QSOs from infrared camera (IRC) on AKARI infrared astronomy satellite. Our $2.5-5.0{\mu}m$ spectra will provide an access to full wavelength spectra of AGNs for the first time. Moreover, we present the Brackett line properties, FWHMs and luminosities, of AGNs. Using these Brackett line properties, we derive new black hole (BH) mass estimators. The new BH mass estimators using NIR hydrogen lines will be very useful to estimate BH mass of dusty red AGNs in the future.

  • PDF

Establishing the Black Hole Mass Estimator of Active Galactic Nuclei with Hydrogen Brackett Lines

  • Kim, Do-Hyeong;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.51.1-51.1
    • /
    • 2011
  • Red dusty Active Galactic Nuclei (AGNs) are suspected to mid-stage between ULIRG and AGN phase. As well as, red AGNs are suspected that they have more than 50% of whole AGN population. In order to understand the character of red AGNs, Black Hole (BH) mass of red AGN is a key property and can not measured by existing method such as reverberation mapping and single epoch method. Thus we still don't know their character and properties in clearly. To estimate properties of red AGNs without the effect of dust-obscuration, we have obtained Near InfraRed (NIR) spectra of 31 reverberation mapped AGNs and 49 Palomar-Green(PG) Quasi-Stellar Object (QSO) by using the infrared camera (IRC) for AKARI with unique wavelength range $2.5-5.0{\mu}m$. From this spectra, we measured the FWHM and luminosity of brackett ${\alpha}$ and ${\beta}$ at 4.0, 2.6 micron meter for deriving new BH mass estimators based on the properties of Brackett line emission.

  • PDF

Research for Calibration and Correction of Multi-Spectral Aerial Photographing System(PKNU 3) (다중분광 항공촬영 시스템(PKNU 3) 검정 및 보정에 관한 연구)

  • Lee, Eun Kyung;Choi, Chul Uong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.4
    • /
    • pp.143-154
    • /
    • 2004
  • The researchers, who seek geological and environmental information, depend on the remote sensing and aerial photographic datum from various commercial satellites and aircraft. However, the adverse weather conditions and the expensive equipment can restrict that the researcher can collect their data anywhere and any time. To allow for better flexibility, we have developed a compact, a multi-spectral automatic Aerial photographic system(PKNU 2). This system's Multi-spectral camera can catch the visible(RGB) and infrared(NIR) bands($3032{\times}2008$ pixels) image. Visible and infrared bands images were obtained from each camera respectively and produced Color-infrared composite images to be analyzed in the purpose of the environment monitor but that was not very good data. Moreover, it has a demerit that the stereoscopic overlap area is not satisfied with 60% due to the 12s storage time of each data, while it was possible that PKNU 2 system photographed photos of great capacity. Therefore, we have been developing the advanced PKNU 2(PKNU 3) that consists of color-infrared spectral camera can photograph the visible and near infrared bands data using one sensor at once, thermal infrared camera, two of 40 G computers to store images, and MPEG board to compress and transfer data to the computer at the real time and can attach and detach itself to a helicopter. Verification and calibration of each sensor(REDLAKE MS 4000, Raytheon IRPro) were conducted before we took the aerial photographs for obtaining more valuable data. Corrections for the spectral characteristics and radial lens distortions of sensor were carried out.

  • PDF

Changes in the Hyperspectral Characteristics of Wheat Plants According to N Top-dressing Rates at Various Growth Stages (밀에서 질소 시비 조건에 따른 생육 단계별 초분광 특성 변화)

  • Jung, Jae Gyeong;Lee, Yeong Hun;Choi, Jae Eun;Song, Gi Eun;Ko, Jong Han;Lee, Kyung Do;Shim, Sang In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.4
    • /
    • pp.377-385
    • /
    • 2020
  • Recently, wheat consumption has been increasing in Korea, requiring increased production. Nitrogen fertilization is a critical determinant in crop yield; therefore, it is necessary to optimize the nitrogen fertilization regime with current trends that emphasize the minimum impact of nitrogen fertilizer on the environment. In this study, both nondestructive spectral analysis using a hyperspectral camera and growth analysis were performed to determine the optimal N top-dressing rates after heading. The nitrogen application regimes consisted of three conditions according to the secondary top-dressing rate: N4:3:0 (0 kg 10 a-1), N4:3:3 (2.73 kg 10 a-1), and N4:3:6 (5.46 kg 10 a-1). Subsequently, growth and physiological investigations were performed at the jointing, heading, and ripening stages of wheat, and spectral investigations were conducted. On April 29, as the nitrogen fertilization rate was increased to N4:3:3 and N4:3:6, plant height and grain yield increased by 4% and 8%, and 8% and 52%, respectively, compared to those under N4:3:0. Leaf area index and SPAD value also increased by 13% and 24%, and 32% and 43%, respectively. The R (red), G (green), and B (blue) of leaf color were lowered by 15, 11, and 4 in N4:3:3 and 44, 34, and 18 in N4:3:6, respectively, as compared to the control. Grain yield was the highest at high top-dressing (N4:3:6), however, there was no difference between no top-dressing (N4:3:0) and intermediat top-dressing (N4:3:3). The reflectance analyzed using a hyperspectral camera showed a difference in the near-infrared (NIR) region on March 19, and on April 29, there was a difference both in the visible light region greater than 550 nm and the NIR region. Vegetation indices differed according to fertilization regime, except for the greenness index (GI). The results of this study showed that not only growth and physiological analysis but also spectral indices can be used to optimize the nitrogen top-dressing rate.

Analysis for Concentration Range of Fluorescein Sodium (플루오레신나트륨의 농도 범위 분석)

  • Lee, Da-Ae;Kim, Yong-Jae;Yoon, Ki-Cheol;Kim, Kwang-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • Brain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.

Mobile Iris Recognition System Based on the Near Infrared Light Illuminator of Long Wavelength and Band Pass Filter and Performance Evaluations (장파장 근적외선 조명 및 밴드 패스 필터 기반 이동형 홍채 인식 시스템 및 성능 평가)

  • Cho, So-Ra;Nam, Gi-Pyo;Jeong, Dae-Sik;Shin, Kwang-Yong;Park, Kang-Ryoung;Shin, Jae-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1125-1137
    • /
    • 2011
  • Recently, there have been previous research about the iris recognition in mobile device to increase portability, whose accuracy is affected by the quality of iris image. Iris image is affected by illumination environment during the image acquisition. The existing system has high accuracy in indoor environment. However the accuracy is degraded in outdoor environment, because the gray levels of iris patterns in image are changed, and ghost and eyelash shading regions are produced by the sunlight of various wavelengths into iris region. To overcome these problems, we propose new mobile iris camera system which uses the near-infrared (NIR) light illuminator of 850 nm and band pass filter (BPF) of 850 nm. To measure the performance of the proposed system, we compared it to the existing one with the iris images captured in indoor and outdoor sunlight environments in terms of the equal error rates (EER) based on false acceptance rate (FAR) and false rejection rate (FRR). The experimental result showed that the proposed system had the lower EERs than those of previous system by 0.96% (with frontal light in indoors), 4.94% (with frontal light in outdoor), 9.24% (with side light in outdoor), and 7% (with back light in outdoor), respectively.

A Study on Non-uniformity Correction Method through Uniform Area Detection Using KOMPSAT-3 Side-Slider Image (사이드 슬리더 촬영 기반 KOMPSAT-3 위성 영상의 균일 영역 검출을 통한 비균일 보정 기법 연구 양식)

  • Kim, Hyun-ho;Seo, Doochun;Jung, JaeHeon;Kim, Yongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1013-1027
    • /
    • 2021
  • Images taken with KOMPSAT-3 have additional NIR and PAN bands, as well as RGB regions of the visible ray band, compared to imagestaken with a standard camera. Furthermore, electrical and optical properties must be considered because a wide radius area of approximately 17 km or more is photographed at an altitude of 685 km above the ground. In other words, the camera sensor of KOMPSAT-3 is distorted by each CCD pixel, characteristics of each band,sensitivity and time-dependent change, CCD geometry. In order to solve the distortion, correction of the sensors is essential. In this paper, we propose a method for detecting uniform regions in side-slider-based KOMPSAT-3 images using segment-based noise analysis. After detecting a uniform area with the corresponding algorithm, a correction table was created for each sensor to apply the non-uniformity correction algorithm, and satellite image correction was performed using the created correction table. As a result, the proposed method reduced the distortion of the satellite image,such as vertical noise, compared to the conventional method. The relative radiation accuracy index, which is an index based on mean square error (RA) and an index based on absolute error (RE), wasfound to have a comparative advantage of 0.3 percent and 0.15 percent, respectively, over the conventional method.