Near Infrared Spectroscopy of LAS (linear alkyl benzene sulfonate) (근적외선 분광분석법을 이용한 LAS (linear alkyl benzene sulfonate)의 정량분석법)

  • 조창희;최병기;김효진
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.39-43
    • /
    • 2000
  • Linear alkyl sulfonates (LAS) constitute a large fraction of the surfactants used in cleaning processes in households, trade and industry Despite the industrial significance and the possible environmental impact of these compounds, the fast and inexpensive determination of LAS concentrations is still a difficult task. In this study, near infrared (NIR) spectroscopy which is a rapid spectroscopic analysis method compared with a traditional analytical method for the measurement of LAS concentration such as HPLC, GC and standard wet chemistry method. NIR spectra of LAS between 0.313 and 25.0% (w/v) in water were utilized to develop a calibration model. The best results (R = 0.998, SEP = 0.244% (w/v)) obtained by using partial least-squares regression with spectral data treatment and 2nd derivatization were comparable to the results (SEC = 0.186% (w/v), SEP = 0.206% (w/v)) obtained by using multiple linear least-squares regression (MLR). However, models based on derivative spectra have no significant advantage with MLR.

  • PDF

A method for quantitative analysis of DEHP in PVC packing material by Near-Infrared Spectroscopy (근적외선 분광광도법을 이용한 PVC포장재 중 DEHP 정량법에 관한연구)

  • 김재관;윤미혜;박포현;김기철
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.61-67
    • /
    • 2002
  • NIRS(Near infrared spectroscopy) scanning from 1300nm to 2400nm was appl ied for the DEHP(di-(2 ethylhexyl)phthalate) in PVC(polyvinyl chloride_packing material. All samples were devided into calibration group and validation group. As a result of conduction the multiple regression analysis on the correlation between the NIR spectrum data and chemical assay value obtained by the Korea Food Sanitation Act. The validation model for measuring the DEHP content had R of 0.997, SEC of 0.132, SEP of 0.176 by MLR and R of 0.996, SEC of 0.142, SEP of 0.198 by PLS and the detection limit was 0.1%. The obtained results indicate that the NIR procedure can potentially be used as a nondestructive analysis method for the purpose of rapid and simple measurement of DEHP in PVC packing material.

Near-infrared Spectroscopic Measurement of Glucose Under the Existence of Other Major Blood Components (혈액의 주요 구성물질 존재 하에서 근적외분광분석법을 이용한 글루코오스 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.171-176
    • /
    • 2004
  • This study was described for measuring clinically relevant levels of glucose in undiluted plasma and whole blood by near-infrared (NIR) spectroscopy. Result from an initial measurement of major blood components powder was over-lapped the absorption bands of glucose at 1500-1600 nm. However, the NIR data of blood components were clearly separated by principle component analysis (PCA) space. By the use of partial least squares (PLS) regression, glucose concentrations in undiluted plasma and whole blood could be determined with standard errors of prediction (SEP) of 15 mg/dl and 76 mg/dl, respectively. Although these blood components possessed strong absorption bands that overlapped with the absorption bands of glucose, successful calibration models could be carried out.

Quantification of intact ambroxol tablet using near-infrared spectroscopy

  • Kim, Do-Hyung;Lim, Hun-Rang;Woo, Young-Ah;Kim, Hyo-Jin;Kang, Shin-Jung;Choi, Hyun-Chul;Choi, Han-Gon
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.279.1-279.1
    • /
    • 2003
  • NIR reflectance spectroscopy, using a fiber-optic probe was used to determine rapidly and non-destructively the content of ambroxol in intact ambroxol 30 mg (nominal content 12.5% m/m ambroxol) tablets by collecting NIR spectra in range 1100 - 1750 nm and using PLSR calibration method. The tablets (10.3 - 15.9% m/m ambroxol, i.e., 82 - 127% of the nominal label content) were used 7 calibration set and 5 validation set. (omitted)

  • PDF

Determination of NaOH, $Na_2CO_3$ and $Na_2S$ Concentration in a Naphtha Cracking Process by FT-NIR Spectroscopy (FT-NIR를 이용한 Naphtha Cracking 공정중 NaOH, $Na_2CO_3$$Na_2S$ 정량분석)

  • Jang, Mijin;Kim, Hyunwook;Cho, Ilyoung
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.448-451
    • /
    • 1998
  • The feasibility of using FT-NIR (Fourier Transform Near Infrared) spectrometer to measure NaOH, $Na_2CO_3$ and $Na_2S$ concentration in a naphtha cracking process, and an outline of the method development to identify spectral feature of the hydroxide whose band is overlapped by a strong water absorption were demonstrated. For measuring NaOH, $Na_2CO_3$ and $Na_2S$, FT-NIR spectrometer is a rapid and possible alternative to the current titration method with a standard deviation of 0.1.

  • PDF

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.