• 제목/요약/키워드: Muscles, US

검색결과 38건 처리시간 0.024초

Correlations Between Maximal Isometric Strength and the Cross-Sectional Area of Lumbrical Muscles in the Hand

  • Jung, Doh-Heon;Lee, Won-Hwee;Kim, Su-Jung;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제18권4호
    • /
    • pp.34-42
    • /
    • 2011
  • The lumbrical muscles contribute to the intrinsic plus position, that is simultaneous metacarpophalangeal (MCP) flexion and interphalangeal (IP) extension. The strength of the lumbrical muscles is necessary for normal hand function. However, there is no objective and efficient method of strength measurement for the lumbrical muscles. In addition, previous studies have not investigated the measurement of the cross-sectional area (CSA) of the lumbrical muscles using ultrasonography (US) and the relationship between lumbrical muscle strength in the intrinsic plus position and the CSA. Therefore, the purpose of this study was to identify the measurement method of the CSA of the lumbrical muscles using US and to examine the relationship between maximal isometric strength and the CSA of lumbrical muscles. Nine healthy males participated in this study. Maximal isometric strength of the second, third, and fourth lumbrical muscles was assessed using a tensiometer in the intrinsic plus position which isolated MCP flexion and IP extension. The CSA of the lumbrical muscles was measured with an US. The US probe was applied on the palmar aspect of the metacarpal head with a transverse view of the hand in resting position. There was no significant difference between maximal isometric strength of the lumbrical muscles, but the fourth lumbrical muscle was stronger than the others. The CSA of the lumbrical muscles was significantly different and the fourth lumbrical muscle was significantly larger than the second lumbrical muscle. There was moderate to good correlation between maximal isometric strength and the CSA of the lumbrical muscles. Therefore, we conclude that maximal isometric strength of the lumbrical muscles was positively correlated to the CSA of the lumbrical muscle in each finger, while the measurement of the CSA of the lumbrical muscles, using US protocol in this study, was useful for measuring the CSA of the lumbrical muscles.

Influence of Difficulty Variation of the Core Stabilization Exercise on Thickness Changes of Abdominal Muscles in Healthy Subjects: A Pilot Study

  • Kang, Jeong-Hyeon;Suh, Hye-Rim;Kim, Chang-Yong;Kim, Hyeong-Dong;Kim, Hyungkun
    • The Journal of Korean Physical Therapy
    • /
    • 제28권2호
    • /
    • pp.112-118
    • /
    • 2016
  • Purpose: This study examined thickness changes in abdominal muscles according to difficulty level of core stabilization exercise in healthy subjects. Methods: Thirty healthy subjects (age range: 21-30 years) volunteered under three conditions. In the first condition, the subjects performed an abdominal draw-in maneuver (ADIM). In the second condition, they performed the ADIM during quadruped exercise using a suspension device without extending their lower limbs. In the third condition, the subjects performed the ADIM during quadruped exercise using a suspension device while extending both lower limbs. The changes in thickness of transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles were measured by ultrasonography (US) imaging during the three experimental conditions, and US was used to measure the improvement ratio of muscle thickness at rest. The interventions were conducted over three trials in each condition, and measurements were performed on each subject by one examiner. Results: Our results showed a significantly greater increase in the muscle thickness of TrA and IO muscles after performance of quadruped exercise using a suspension device without knee extension (p<0.05) compared to the other conditions. The results also showed a significantly greater increase in the thickness changes of EO muscle in those who performed the ADIM during quadruped exercise using a suspension device with knee extension (p<0.05) compared with the ADIM only. Conclusion: These findings demonstrated positive evidence that a low-level core stabilization exercise could improve thickness of abdominal muscles.

데드리프트와 업라이트로우 시 운동강도에 따른 근활성도 평가 (Evaluation of Muscle Activity according to Exercise Intensity during the Deadlift and Upright Row)

  • Cho, Won Jun;Song, Ju Won;Choi, Myung Soo;Kim, Nam Yim;Kim, Ryong;Lee, Chang Min;Hong, Jae Heon;Kang, Gun Woo;Moon, Young Jin
    • 한국운동역학회지
    • /
    • 제31권4호
    • /
    • pp.270-275
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate 16 muscles activity according to three exercise intensity when performing Deadlift and Upright row. Method: To accomplish the purpose of the study, subjects (n=10) were performed Electromyography (EMG) measurement for 16 different muscles. The experimental movements were Deadlift and Upright row, measured five times for each intensity (40%, 60%, 80%) of 1RM. This study normalized the EMG values through RVC for comparative analysis. Results: The results were summarized as follows: As a result of Deadlift, there was significant difference in the mean EMG value according to the exercise intensity in all muscles except RA, PM and BB (p<.05). As a result of Upright row, There was significant difference in the mean EMG value according to the exercise intensity in all muscles except BF, TA, GN, RA and UT (p<.05). Conclusion: This study allowed us to know the activities of major muscles according to the exercise intensity for 16 different muscles when performing Deadlift and Upright row.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

Muscle Fiber Typing in Bovine and Porcine Skeletal Muscles Using Immunofluorescence with Monoclonal Antibodies Specific to Myosin Heavy Chain Isoforms

  • Song, Sumin;Ahn, Chi-Hoon;Kim, Gap-Don
    • 한국축산식품학회지
    • /
    • 제40권1호
    • /
    • pp.132-144
    • /
    • 2020
  • The aim of this study was to optimize staining procedures for muscle fiber typing efficiently and rapidly in bovine and porcine skeletal muscles, such as longissimus thoracis, psoas major, semimembranosus, and semitendinosus muscles. The commercially available monoclonal anti-myosin heavy chain (MHC) antibodies and fluorescent dye-conjugated secondary antibodies were applied to immunofluorescence histology. Two different procedures, such as cocktail and serial staining, were adopted to immunofluorescence analysis. In bovine muscles, three pure types (I, IIA, and IIX) and one hybrid type, IIA+IIX, were identified by the cocktail procedure with a combination of BA-F8, SC-71, BF-35, and 6H1 anti-MHC antibodies. Porcine muscle fibers were typed into four pure types (I, IIA, IIX, and IIB) and two hybrid types (IIA+IIX and IIX+IIB) by a serial procedure with a combination of BA-F8, SC-71, BF-35, and BF-F3. Unlike for bovine muscle, the cocktail procedure was not recommended in porcine muscle fiber typing because of the abnormal reactivity of SC-71 antibody under cocktail procedure. Within the four antibodies, combinations of two or more anti-MHC antibodies allowed us to distinguish pure fiber types or all fiber types including hybrid types. Application of other secondary antibodies conjugated with different fluorescent dyes allowed us to get improved image resolution that clearly distinguished hybrid fibers. Muscle fiber characteristics differed depending on species and muscle types.

해부학적 변이를 가지는 전방골간신경 증후군: 1예 보고 (Anterior Interosseous Nerve Syndrome with Varient Nerve Innervation: A Case Report)

  • 이준호;나재범;김재수;유진종;이경규;정성훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권2호
    • /
    • pp.147-151
    • /
    • 2002
  • 전방골간신경 증후군은 전방골간신경의 질환으로서, 장무지 굴근, 심수지 굴근 및 방형 회내근의 마비가 나타나고, 감각은 정상인 것이 특징적이다. 전방골간신경 증후군은 많이 알려져 있으나 자기공명영상 소견에 대한 보고는 적으며, 신경 분포의 해부학적 변이를 가지는 전방골간신경 증후군에 관한 보고는 더욱 드물다. 저자들은 정상변이의 신경분포를 보이는 전방골간신경 증후군 증례를 1예 경험하였기에 방사선학적 소견을 문헌고찰과 함께 보고하고자 한다.

  • PDF

경추부의 초음파 적용: 임상화보 (Musculoskeletal Ultrasound Application in Cervical Spine: Pictorial Essay)

  • 윤용순;이정후;김은실;이광재
    • Clinical Pain
    • /
    • 제20권2호
    • /
    • pp.74-85
    • /
    • 2021
  • Ultrasound (US) can depict of various anatomical structures, such as muscles, tendons, ligaments, nerve roots, and vessels, around the neck. The usage of US around the neck is increasing due to its quick and easy application for guided injection for nerves, tendons, and joints. This article elaborates the degenerative diseases causing neck pain, sonoanatomy, and the use of US for diagnosis and intervention; for example, small nerves around the neck, cervical root, stellate ganglion, medial branches, greater occipital nerve (GON), and third occipital nerve (TON). The aim of this review article is to lead readers to understand the anatomy around the neck and structural relations, and to get to know about several US-guided intervention of the neck.

Comparison of three different surface plank exercises on core muscle activity

  • Lee, Jin;Jeong, Kwanghyun;Lee, Hyuna;Shin, Jaeyeon;Choi, Jaelim;Kang, Seungbeom;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권1호
    • /
    • pp.29-33
    • /
    • 2016
  • Objective: This study compared the muscle activities of the erector spinae (ES), the external oblique (EO), and the rectus abdominis (RA) on three different surfaces. The purpose of this study was to determine which surface induces the highest muscle activity during the plank exercises. The information from this study can be used to recommend plank exercises to athletes and patients with weak core muscles. Design: Cross-sectional study. Methods: The subjects include 20 adult males attending S University in Seoul. Participants completed each plank exercise on three different surfaces. To measure muscle activities, researchers used the values from electromyography. The measurement excluded the initial two and final two seconds and collected information on the RA, EO, and ES in each posture of each subject. Results: The left external oblique showed significant differences between the plank position on stable ground (ST) and the plank position using a suspension device (SL) (p<0.05) and between the plank position on the unstable ground (US) and SL (p<0.05). The right rectus abdominis and left rectus abdominis displayed statistically significant differences between the ST and the US (p<0.05) and between the ST and the SL (p<0.05). The right erector spinae had a statistically significant difference between ST and US (p<0.05). Conclusions: The plank exercise strengthens the core muscles effectively, and muscle activity is related to the posture of the exercise and the location of the muscle. These results suggest that plank exercises improve muscle activities. Additionally, plank exercises can be applied to general medical care.

Quality Assessment of Longissimus and Semitendinosus Muscles from Beef Cattle Subjected to Non-penetrative and Penetrative Percussive Stunning Methods

  • Sazili, A.Q.;Norbaiyah, B.;Zulkifli, I.;Goh, Y.M.;Lotfi, M.;Small, A.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권5호
    • /
    • pp.723-731
    • /
    • 2013
  • This study provides a comparative analysis of the effects of pre-slaughter penetrative and non-penetrative stunning and post-slaughter stunning on meat quality attributes in longissimus lumborum (LL) and semitendinosus (ST) muscles in heifers. Ten animals were assigned to each of four treatment groups: i) animals were subjected to conventional Halal slaughter (a clean incision through the structures at the front of the upper neck - the trachea, oesophagus, carotid arteries and jugular veins) and post-cut penetrating mechanical stun within 10 to 20 s of the neck cut (Unstunned; US); ii) high power non-penetrating mechanical stunning followed by the neck cut (HPNP); iii) low power non-penetrating mechanical stunning followed by the neck cut (LPNP); and iv) penetrative stunning using a captive bolt pistol followed by the neck cut (P). For each carcass, muscle samples were removed within 45 min of slaughter, portioned and analysed for pH, cooking loss, water holding capacity (WHC), tenderness (WBS), lipid oxidation (TBARS) and color, over a two week storage period. Stunning did not affect pH and cooking loss. Significant differences in water holding capacity, tenderness, lipid oxidation and color were present at different storage time points. HPNP stunning resulted in lower WHC and color values, particularly lightness ($L^*$), higher TBARS values and peak force values compared with those stunned using LPNP, P and US. These adverse effects on quality were mostly encountered in the ST muscle. In conclusion, the meat quality achieved using P, LPNP and US treatments was comparable, and no treatment stood out as considerably better than another.

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.