• Title/Summary/Keyword: Multiple Test

Search Result 8,672, Processing Time 0.036 seconds

Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard (IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구)

  • Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

A Studies on Symmetric Type Multiple Unit Roots Test

  • Yil-Yong;I, Key-I
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.1
    • /
    • pp.107-118
    • /
    • 2000
  • Due to the close relation between cointegration test and multiple unit roots test multiple unit roots test are greatly studied by many researchers,. In this paper we suggest the symmetric type unit roots test which is an adjusted method of Shin (1999) Also we have a small Monte-Carlo simulation study to compare the power of the statistic developed in this paper with those of Shin (1999) and adjusted Fuller statistic(1996)

  • PDF

Comparison of the Effects of Dynamic Postural Stability Training Versus Soft Ankle Bracing on Multiple Hop Performance in Participants With Functional Ankle Instability (기능적 발목 불안정성을 가진 대상자에게 동적 자세 안정성 훈련과 연성 발목 보조기가 다중 한발 뛰기 수행에 미치는 효과 비교)

  • Cha, Youn-sang;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Background: The multiple hop test is an active performance test that has been commonly used to assess individuals with functional ankle instability. Previous studies have suggested that insufficiency of dynamic postural stability and passive stability during dynamic activities can have an influence on performance in the multiple hop test. However, no study has investigated the effects of dynamic postural stability training and ankle bracing on multiple hop test performance in individuals with functional ankle instability. Objects: The purpose of this study was to compare the immediate effects of dynamic postural stability training versus ankle bracing in the performance of the multiple hop test for participants with functional ankle instability. Methods: Twenty-nine participants with functional ankle instability who scored below 24 in the Cumberland Ankle Instability Tool were selected. The participants were randomly divided into two groups: a dynamic postural stability training group (n1=14) and an ankle bracing control group ($n_2=15$). The multiple hop tests were performed before and after applying each intervention. Dynamic postural stability training was performed using visual-feedback-based balance-training equipment; participants in this group were asked to perform a heel raise in a standing position while watching the centering of their forefoot pressure to prevent excessive ankle inversion. Ankle bracing was applied in the control group. Results: When comparing the pre- and post-intervention period for both groups, both methods significantly improved the results of the multiple hop test (p<.05). However, no significant differences were shown between the dynamic postural stability training and ankle bracing groups (p>.05). Conclusion: Both dynamic postural stability training and ankle bracing showed significant improvement (2.85 seconds and 2.05 seconds, respectively) in test performance. Further study is needed to determine the long-term effects of dynamic postural stability training and to determine whether insufficient dynamic postural stability is a causative factor for functional ankle instability.

An On-Chip Test Clock Control Scheme for Circuit Aging Monitoring

  • Yi, Hyunbean
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.71-78
    • /
    • 2013
  • In highly reliable and durable systems, failures due to aging might result in catastrophes. Aging monitoring techniques to prevent catastrophes by predicting such a failure are required. Aging can be monitored by performing a delay test at faster clocks than functional clock in field and checking the current delay state from the test clock frequencies at which the delay test is passed or failed. In this paper, we focus on test clock control scheme for a system-on-chip (SoC) with multiple clock domains. We describe limitations of existing at-speed test clock control methods and present an on-chip faster-than-at-speed test clock control scheme for intra/inter-clock domain test. Experimental results show our simulation results and area analysis. With a simple control scheme, with low area overhead, and without any modification of scan architecture, the proposed method enables faster-than-at-speed test of SoCs with multiple clock domains.

Bayesian test for the differences of survival functions in multiple groups

  • Kim, Gwangsu
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.2
    • /
    • pp.115-127
    • /
    • 2017
  • This paper proposes a Bayesian test for the equivalence of survival functions in multiple groups. Proposed Bayesian test use the model of Cox's regression with time-varying coefficients. B-spline expansions are used for the time-varying coefficients, and the proposed test use only the partial likelihood, which provides easier computations. Various simulations of the proposed test and typical tests such as log-rank and Fleming and Harrington tests were conducted. This result shows that the proposed test is consistent as data size increase. Specifically, the power of the proposed test is high despite the existence of crossing hazards. The proposed test is based on a Bayesian approach, which is more flexible when used in multiple tests. The proposed test can therefore perform various tests simultaneously. Real data analysis of Larynx Cancer Data was conducted to assess applicability.

Design of Multiple-Purpose Protocol Test System (다기능 프로토콜 시험시스템 설계)

  • 최양희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.5
    • /
    • pp.434-445
    • /
    • 1990
  • Protocol testing techniques are expanded from the traditional simple function- testing based on the OSI model, to sophisticated performance testing, conformance testing and interoperability testing. In addition, both point-to-point and point-to-multipoint protocols are to be covered. This paper presents a new multiple-purpose protocol test system where the common platform includes the test sequence generation and test result analysis, and the modular test execution part is selectively adjusted according to the test purposes and protocols under test. This paper describes test system for network routing protocol and test system for transport protocol, designed upon the ideas of the multiple-purpose protocol test system.

  • PDF

A Pilot Study for the Standardization of a Multiple Intelligences Performance Test for Preschoolers (유아를 위한 수행형 다중지능 검사의 표준화 예비연구)

  • Chang-Song, You-Kyung;Choi, Yun-Young
    • Korean Journal of Child Studies
    • /
    • v.29 no.6
    • /
    • pp.163-176
    • /
    • 2008
  • The purpose of this study was to develop a standardized performance style Multiple Intelligences Test for preschoolers(MIT-P). A total of 270 preschoolers(3~5-years-old) participated in this study. Tools and procedures were developed to measure performance in 7 areas of multiple Intelligences(linguistic, mathematical, science, social, music, art and kinesthetic). The final test set included 138 items. Reliability of the MIT-P was relatively high(Cronbach alpha =.92). Intercorrelations among measures of the 7 areas indicated construct validity. Based on these results, the pilot study of MIT-P is considered adequate to form the basis of a new test that would help teachers and parents to identify children's strengths and weaknesses and may be useful for educational planning.

  • PDF

An Empirical Test for the Combination of Multiple Recursive Generators (다중귀납난수생성기의 경험적 검정)

  • 김태수;이영해
    • Journal of the Korea Society for Simulation
    • /
    • v.10 no.2
    • /
    • pp.25-32
    • /
    • 2001
  • The Multiple Recursive Generator(MRG) has been considered by many scholars as a very good random number generator. For the long period md excellent statistical properties, the method of the combination with random number generators is used. In this paper, we thought the two-combined MRGs. Using the frequency and serial test, and runs test, we studied the importance of the initial seeds likewise other random number generators.

  • PDF

Displaying Multiple Maritime Surveillance Radar Data (다수의 해안감시 레이더자료 전시 기법)

  • Hwang, Gyu-Hwan;Kim, Moon-Ki;Kang, Do-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1041-1048
    • /
    • 2012
  • We display important test information from radar, telemetry in real time for monitoring and control of guided missile flight test. Clearing test area is the most important thing for safety. Thus, we have to constantly monitor and control ships around the test area. Several maritime surveillance radars are deployed around the test area for that purpose. However, multiple points are displayed for the same target when using multiple surveillance radars and this confuses the test personnel during the mission. In this paper, we suggested a method to solve this problem by analyzing error factor of surveillance radar and comparing the correlation of each radar data.

A Study on Composing the Structural Test Equipment of Large Scale Beam Type Test Specimen to Load Multiple Point and Capacity (대형 보형 실험체의 다점 다하중 가력을 위한 실험장치 구성에 관한 연구)

  • Park, Dong Su;Lee, Kyung Jin;Ham, Kyung Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.189-197
    • /
    • 2011
  • In the field of structural test, it is a very important factor to apply with an appropriate test jig to enhance test accuracy and efficiency. Especially in the large scale structure test, proper test apparatus scheme will reduce overall cost and time of the test project. Actuators, oil jack and UTM is generally used to evaluate the flexural capacity of the test beam. But in the case of multiple loading point or asymmetric loading of large scale test specimen, existing test method such as UTM have a difficulty in giving an accurate load. In this study new test method which is composed of existing test apparatus will be developed to improve test accuracy and economic efficiency.