• Title/Summary/Keyword: Multiple Defect

Search Result 264, Processing Time 0.026 seconds

Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong;Hong, Young-Gi;Kim, Hyo-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.411-416
    • /
    • 2016
  • Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth.

Prediction of Fatigue Life using Extreme Statistics Analysis (표면미소균열의 극치통계해석을 이용한 피로수명예측)

  • Lee, Dong-U;Hong, Sun-Hyeok;Jo, Seok-Su;Ju, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1746-1752
    • /
    • 2002
  • Fatigue fracture in machine components is produced by surface micro-crack from stress concentration area such as notch and material defect. It is difficult to predict the remaining fatigue lift of mechanical components because the surface micro-crack on critical area initiates and grows with statistical distribution. Plane bending fatigue tests were carried out on the plain specimen of Al 2024-T3 and the initiation and growth behavior of surface micro cracks were observed. The statistical distribution of surface length of multiple micro cracks and their maximum length were investigated. The maximum surface crack length distributions were analyzed on the basis of the statistics of extremes in order to examine the prediction of remaining life.

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

Neuro-Fuzzy System for Predicting Optimal Weld Parameters of Horizontal Fillet welds

  • Moon, H.S.;Na, S.J.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.2
    • /
    • pp.36-44
    • /
    • 2001
  • To get the appropriate welding process variables, mathematical modeling in conjunction with many experiments is necessary to predict the magnitude of weld bead shape. Even though the experimental results are reliable, it has a difficulty in accurately predicting welding process variables for the desired weld bead shape because of nonlinear and complex characteristics of welding processes. The welding condition determined for the desired weld bead shape may cause the weld defect if the welding current/voltage/speed combination is improperly selected. In this study, the $2^{n-1}$ fractional factorial design method and correlation parameter were used to investigate the effect of the welding process variables on the fillet joint shape, and the multiple non-linear regression analysis was used for modeling the gas metal arc welding(GMAW)parameters of the fillet joint. Finally, a fuzzy rule-based method and a neural network method were proposed so that the complexity and non-linearity of arc welding phenomena could be effectively overcome. The performance of the proposed neuro-fuzzy system was evaluated through various experiments. The experimental results showed that the proposed neuro-fuzzy system could effectively check the welding conditions as to whether or not weld defects would occur, and also adjust the welding conditions to avoid these weld defects.

  • PDF

Primary Sternal Tuberculosis with Spontaneous Fracture Treated by Resection and Reconstruction -A Case Report- (원발성 흉골결핵의 외과적 치험 -1례 보고-)

  • 배상일;김미혜;오태윤;장운하
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.190-193
    • /
    • 1998
  • We experienced a case of primary sternal tuberculosis with destroyed midsternum and bony defect. An 22-year-old female was admitted to our hospital two times for severe sternal pain and spontaneous fracture without history of trauma. On hospital admission, chest X-ray and chest CT showed destruction of midsternum and soft tissue swelling. Fine needle aspiration cytology revealed tuberculous osteomyelitis with cold abscess. And the patient was treated with usual anti-tubeculosis medication for preoperative preparation. At operation, we confirmed midsternal destruction with cold abscess and multiple sinus tracts. After removal of diseased sternal segment and cold abscess, we performed sternal reconstruction with autologus iliac bone graft. The pathologic report was compatible with tuberculous osteomyelitis and caseous necrosis The postoperative course was smooth and uneventful, and she remains well without sternal instability two months later.

  • PDF

Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

Modified Anterior Craniofacial Osteotomy Using Partial Nasal Bone Division and Reconstruction in Frontoethmoidal Sinus Meningioma

  • Park, Eon Ju;Kim, Hong Il;Park, Jin Hyung;Yi, Hyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.117-121
    • /
    • 2017
  • Typical transcranial approaches are insufficient for adequate visualization and resection of skull base tumors. Different approaches with multiple modifications have been attempted. Here, we describe a new approach for a lesion that is central and hard to treat by conventional craniotomy and successful reconstruction with calvarial bone graft and titanium mesh plate. A 69-year-old female patient presented with recurrent meningioma. The tumor had invaded the frontal lobe, right supraorbital rim, and ethmoidal bone. We performed a modified anterior craniofacial approach that fully exposed the tumor and invaded bone. In consideration of the patient's age and cosmetic result, the tumor and invaded bone was resected and the defect area was reconstructed with titanium mesh and calvarial bone graft. At 6 months postoperative the patient had no complications and was satisfied with the esthetic result. We report this case to demonstrate the successful approach and reconstruction using this technique.

Remote Cerebral and Cerebellar Hemorrhage after Massive Cerebrospinal Fluid Leakage

  • You, Sung-Hye;Son, Kyu-Ri;Lee, Nam-Joon;Suh, Jung-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.4
    • /
    • pp.240-243
    • /
    • 2012
  • Dural tears can occur during spinal surgery and may lead to cerebrospinal fluid (CSF) leakage which is rarely involved in remote cerebellar hemorrhage. Only a few of cases of simultaneous cerebral and cerebellar hemorrhage have been reported in the English literature. We experienced a case of multiple remote cerebral and cerebellar hemorrhages in a 63-year-old man who exhibited no significant neurologic deficits after spinal surgery. Magnetic resonance imaging (MRI) performed 4 days after the surgery showed a large amount of CSF leakage in the lumbosacral space. The patient underwent the second surgery for primary repair of the dural defect, but complained of headache after dural repair surgery. Brain MRI taken 6 days after the dural repair surgery revealed multifocal remote intracerebral and cerebellar hemorrhages in the right temporal lobe and both cerebellar hemispheres. We recommend diagnostic imaging to secure early identification and treatment of this complication in order to prevent serious neurologic deficits.

Ultrasonic Testing Simulation in Austenitie Stainless Steel Weld by Ray Tracing Technique (선추적기법을 활용한 오스테나이트계 스텐레스강 용접부 초음파탐상 모의)

  • Lee, S.L.;Lim, H.T.;Park, C.S.;Kim, B.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.310-317
    • /
    • 1995
  • Crack detection technique by ultrasonics in structures and components made of austenitic stainless steel often loses its reliability due to the material characteristics during inservice inspection of nuclear power plants, especially in the area of detection and sizing in centrifugally cast stainless steel pipings. In order to understand and overcome this problem, computer program for tracing the ultrasonic rays within material has been developed to simulate the process of defect detection within weld. The program simulates through transmission and reflection technique in crack detection of austenitic stainless steel as well as ultrasonic beam propagation through multiple media including stainless steel cladding interface.

  • PDF

Revascularization of Popliteal Artery Injury in Trauma Around Knee Joint (슬관절주위 외상에 의한 슬와동맥 손상의 재혈관화)

  • Han, Soo-Hong;Shin, Dong-Eun;Dan, Jin-Myung;Kim, Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • Popliteal artery injury in blunt trauma of knee joint is not common but poses high rate of amputation due to anatomical characteristics or delayed diagnosis and treatment. The aim of the present study is to review the authors' experiences with this condition and identify factors contributing to disability. We reviewed 7 cases of popliteal artery injury in trauma around knee. Injury mechanism, type of vessel damage, associated injuries, mangled extremity severity scores (MESS), ischemic time and additional treatments were analyzed. Tibial fracture, distal femoral fracture and serious soft tissue defect were combined. Mean MESS was 9.9 point and mean time of revascularization was 7.1 hours. Transfemoral amputation was performed in 2 cases due to vascular insufficiency and devastating infection, and 4 patients were able to walk without any support at the last follow up. Age, the severity of soft tissue injury, ischemic time and MESS are thought to be related to prognosis, and young patients with short ischemic time show best results, but authors experienced one exceptional case. We have to consider multiple factors related to the prognosis in popliteal artery injury with fractures around knee, and careful decision is needed regarding to early amputation.

  • PDF